Files
2026-10-23 16:13:31 +00:00

497 lines
25 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Mon Nov 15 14:09:12 2021 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_1230</Name>
<ModelId Id="1230"></ModelId>
<BBox_Min Z="-0.200" Y="-1.140" X="-1.140"></BBox_Min>
<BBox_Max Z="5.710" Y="7.140" X="10.140"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.000" X="0.000"></BBox_Min>
<BBox_Max Z="0.000" Y="6.017" X="9.012"></BBox_Max>
<Polygon>
<Name>p3771</Name>
<Vertex>
<Name>p3771/V1</Name>
<Coord X="9.012" Y="6.017" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3771/V2</Name>
<Coord X="0.000" Y="6.017" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3771/V3</Name>
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3771/V4</Name>
<Coord X="9.012" Y="0.000" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0.00</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.200" Y="-0.708" X="-0.064"></BBox_Min>
<BBox_Max Z="2.700" Y="6.725" X="3.198"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="0.000" Y="5.837" X="3.018"></BBox_Max>
<Polygon>
<Name>p3754</Name>
<Vertex>
<Name>p3754/V1</Name>
<Coord X="3.018" Y="5.837" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3754/V2</Name>
<Coord X="0.180" Y="5.837" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3754/V3</Name>
<Coord X="0.180" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3754/V4</Name>
<Coord X="3.018" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0010</Name>
<SubId ID="11010"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.902" Y="6.125" X="1.57"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0011</Name>
<SubId ID="11011"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.039" Y="4.544" X="-0.21100000000000002"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0012</Name>
<SubId ID="11012"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.049" Y="2.029" X="-0.20900000000000002"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.113" Y="-0.184" X="1.418"></Coord>
<Dir Z="-0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.330" Y="0.180" X="0.679"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.211" X="1.605"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_102</Name>
<SubId ID="2102"></SubId>
<Group>
<Name>undest_room_102</Name>
<BBox_Min Z="-0.200" Y="0.000" X="3.018"></BBox_Min>
<BBox_Max Z="3.827" Y="6.017" X="6.015"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="3.198"></BBox_Min>
<BBox_Max Z="0.000" Y="5.837" X="5.835"></BBox_Max>
<Polygon>
<Name>p3755</Name>
<Vertex>
<Name>p3755/V1</Name>
<Coord X="5.835" Y="5.837" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3755/V2</Name>
<Coord X="3.198" Y="5.837" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3755/V3</Name>
<Coord X="3.198" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3755/V4</Name>
<Coord X="5.835" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>subroom_1</Name>
<BBox_Min Z="0.000" Y="2.896" X="4.810"></BBox_Min>
<BBox_Max Z="1.269" Y="4.821" X="5.835"></BBox_Max>
</Group>
<Group>
<Name>subroom_2</Name>
<BBox_Min Z="1.269" Y="4.821" X="3.198"></BBox_Min>
<BBox_Max Z="1.269" Y="5.837" X="5.835"></BBox_Max>
</Group>
<Group>
<Name>subroom_3</Name>
<BBox_Min Z="1.269" Y="2.454" X="3.198"></BBox_Min>
<BBox_Max Z="2.700" Y="4.822" X="4.227"></BBox_Max>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0009</Name>
<SubId ID="11009"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.249" Y="6.123" X="5.256"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.435" Y="-0.106" X="4.959"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_2</Name>
<SubId ID="14002"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.330" Y="0.180" X="5.522"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_5</Name>
<SubId ID="16005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="1.569" Y="5.334" X="4.536"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.502" X="4.579"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_103</Name>
<SubId ID="2103"></SubId>
<Group>
<Name>undest_room_103</Name>
<BBox_Min Z="-0.200" Y="-0.708" X="5.835"></BBox_Min>
<BBox_Max Z="2.700" Y="3.227" X="9.076"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="6.015"></BBox_Min>
<BBox_Max Z="0.000" Y="3.047" X="8.832"></BBox_Max>
<Polygon>
<Name>p3756</Name>
<Vertex>
<Name>p3756/V1</Name>
<Coord X="8.832" Y="3.047" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3756/V2</Name>
<Coord X="6.015" Y="3.047" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3756/V3</Name>
<Coord X="6.015" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3756/V4</Name>
<Coord X="8.832" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0003</Name>
<SubId ID="11003"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.109" Y="-0.187" X="7.012"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0005</Name>
<SubId ID="11005"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.048" Y="1.463" X="9.174999999999999"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_3</Name>
<SubId ID="16003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.645" X="7.456"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_5</Name>
<SubId ID="14005"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.269" Y="0.180" X="8.520"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_104</Name>
<SubId ID="2104"></SubId>
<Group>
<Name>undest_room_104</Name>
<BBox_Min Z="-0.200" Y="3.047" X="5.835"></BBox_Min>
<BBox_Max Z="2.700" Y="6.725" X="9.076"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="3.227" X="6.015"></BBox_Min>
<BBox_Max Z="0.000" Y="5.837" X="8.832"></BBox_Max>
<Polygon>
<Name>p3757</Name>
<Vertex>
<Name>p3757/V1</Name>
<Coord X="8.832" Y="5.837" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3757/V2</Name>
<Coord X="6.015" Y="5.837" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3757/V3</Name>
<Coord X="6.015" Y="3.227" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3757/V4</Name>
<Coord X="8.832" Y="3.227" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0008</Name>
<SubId ID="11008"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.028" Y="6.202" X="7.554"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0006</Name>
<SubId ID="11006"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.054" Y="3.994" X="9.176"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_3</Name>
<SubId ID="14003"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.330" Y="5.837" X="8.140"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_4</Name>
<SubId ID="16004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.540" X="7.421"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=2.7</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.500" Y="-0.736" X="-0.200"></BBox_Min>
<BBox_Max Z="5.710" Y="6.754" X="9.210"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="2.700" Y="5.837" X="8.832"></BBox_Max>
<Polygon>
<Name>p3761</Name>
<Vertex>
<Name>p3761/V1</Name>
<Coord X="8.832" Y="5.837" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p3761/V2</Name>
<Coord X="0.180" Y="5.837" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p3761/V3</Name>
<Coord X="0.180" Y="0.180" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p3761/V4</Name>
<Coord X="8.832" Y="0.180" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>subroom_4</Name>
<BBox_Min Z="2.700" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="2.700" Y="5.837" X="3.198"></BBox_Max>
</Group>
<Group>
<Name>subroom_5</Name>
<BBox_Min Z="2.700" Y="0.180" X="3.198"></BBox_Min>
<BBox_Max Z="2.700" Y="2.454" X="5.835"></BBox_Max>
</Group>
<Group>
<Name>subroom_6</Name>
<BBox_Min Z="2.700" Y="0.180" X="5.835"></BBox_Min>
<BBox_Max Z="2.700" Y="5.837" X="8.832"></BBox_Max>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0013</Name>
<SubId ID="11013"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.959" Y="2.98" X="-0.136"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0007</Name>
<SubId ID="11007"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.955" Y="2.975" X="9.100999999999999"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0004</Name>
<SubId ID="11004"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.93877" Y="1.2042300000000001" X="5.968"></Coord>
<Dir Z="0.707" Y="-0.707" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_6</Name>
<SubId ID="16006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.074" Y="3.021" X="7.381"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_7</Name>
<SubId ID="16007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.074" Y="3.039" X="1.511"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_4</Name>
<SubId ID="14004"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.748" Y="3.404" X="0.180"></Coord>
<Dir Z="0.000" Y="0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_3</Name>
<Comment>base_height=5.71</Comment>
<Switch>
<Name>SW_room_301</Name>
<SubId ID="2301"></SubId>
<Group>
<Name>undest_room_301</Name>
<BBox_Min Z="2.529" Y="-0.736" X="-0.200"></BBox_Min>
<BBox_Max Z="5.710" Y="6.754" X="9.210"></BBox_Max>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="2.250" Y="0.100" X="-0.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="1.500" X="-1.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="4.500" X="-1.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="7.070" X="2.500"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="7.070" X="6.500"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_5</Name>
<SubId ID="15005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="4.500" X="10.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_6</Name>
<SubId ID="15006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="1.500" X="10.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_7</Name>
<SubId ID="15007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.070" X="6.500"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_8</Name>
<SubId ID="15008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.070" X="2.500"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.600" Y="2.336" X="2.918"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>