Files
2026-10-23 16:13:31 +00:00

973 lines
50 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Tue Dec 07 10:34:13 2021 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_3129</Name>
<ModelId Id="1129"></ModelId>
<BBox_Min Z="-0.300" Y="-1.140" X="-1.140"></BBox_Min>
<BBox_Max Z="8.671" Y="7.122" X="19.140"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.000" X="0.000"></BBox_Min>
<BBox_Max Z="0.000" Y="6.000" X="18.000"></BBox_Max>
<Polygon>
<Name>p6862</Name>
<Vertex>
<Name>p6862/V1</Name>
<Coord X="18.000" Y="6.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6862/V2</Name>
<Coord X="0.000" Y="6.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6862/V3</Name>
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6862/V4</Name>
<Coord X="18.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0.00</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.300" Y="-0.151" X="-0.075"></BBox_Min>
<BBox_Max Z="3.825" Y="6.156" X="2.870"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="2.690"></BBox_Max>
<Polygon>
<Name>p6856</Name>
<Vertex>
<Name>p6856/V1</Name>
<Coord X="2.690" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6856/V2</Name>
<Coord X="0.180" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6856/V3</Name>
<Coord X="0.180" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6856/V4</Name>
<Coord X="2.690" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0005</Name>
<SubId ID="11005"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.096" Y="-0.1" X="1.726"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0019</Name>
<SubId ID="11019"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.053" Y="6.1160000000000005" X="1.422"></Coord>
<Dir Z="0.000" Y="1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.825" Y="1.604" X="-0.20600000000000002"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.087" Y="4.25" X="-0.133"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.264" X="1.431"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_102</Name>
<SubId ID="2102"></SubId>
<Group>
<Name>undest_room_102</Name>
<BBox_Min Z="-0.300" Y="2.149" X="2.690"></BBox_Min>
<BBox_Max Z="2.700" Y="6.075" X="6.042"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="2.329" X="2.870"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="5.862"></BBox_Max>
<Polygon>
<Name>p6857</Name>
<Vertex>
<Name>p6857/V1</Name>
<Coord X="5.862" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6857/V2</Name>
<Coord X="2.870" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6857/V3</Name>
<Coord X="2.870" Y="2.329" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6857/V4</Name>
<Coord X="5.862" Y="2.329" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0018</Name>
<SubId ID="11018"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.809" Y="6.186" X="4.564"></Coord>
<Dir Z="0.000" Y="1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.992" X="4.406"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.297" Y="5.820" X="5.440"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_103</Name>
<SubId ID="2103"></SubId>
<Group>
<Name>undest_room_103</Name>
<BBox_Min Z="-0.300" Y="2.149" X="5.862"></BBox_Min>
<BBox_Max Z="2.700" Y="6.075" X="9.571"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="2.329" X="6.042"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="9.391"></BBox_Max>
<Polygon>
<Name>p6858</Name>
<Vertex>
<Name>p6858/V1</Name>
<Coord X="6.042" Y="2.329" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6858/V2</Name>
<Coord X="9.391" Y="2.329" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6858/V3</Name>
<Coord X="9.391" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6858/V4</Name>
<Coord X="6.042" Y="5.820" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0017</Name>
<SubId ID="11017"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.808" Y="6.194" X="7.988"></Coord>
<Dir Z="0.000" Y="1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_3</Name>
<SubId ID="16003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.981" X="7.737"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_2</Name>
<SubId ID="14002"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.297" Y="5.820" X="9.067"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_104</Name>
<SubId ID="2104"></SubId>
<Group>
<Name>undest_room_104</Name>
<BBox_Min Z="-0.300" Y="2.149" X="9.391"></BBox_Min>
<BBox_Max Z="2.700" Y="6.075" X="13.060"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="2.329" X="9.571"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="12.880"></BBox_Max>
<Polygon>
<Name>p6859</Name>
<Vertex>
<Name>p6859/V1</Name>
<Coord X="12.880" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6859/V2</Name>
<Coord X="9.571" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6859/V3</Name>
<Coord X="9.571" Y="2.329" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6859/V4</Name>
<Coord X="12.880" Y="2.329" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0016</Name>
<SubId ID="11016"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.804" Y="6.187" X="11.499"></Coord>
<Dir Z="0.000" Y="1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_4</Name>
<SubId ID="16004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.997" X="11.219"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_3</Name>
<SubId ID="14003"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.297" Y="5.820" X="12.409"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_105</Name>
<SubId ID="2105"></SubId>
<Group>
<Name>undest_room_105</Name>
<BBox_Min Z="-0.300" Y="-0.151" X="12.880"></BBox_Min>
<BBox_Max Z="2.700" Y="6.156" X="18.000"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="13.060"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="17.910"></BBox_Max>
<Polygon>
<Name>p6860</Name>
<Vertex>
<Name>p6860/V1</Name>
<Coord X="17.910" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6860/V2</Name>
<Coord X="13.060" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6860/V3</Name>
<Coord X="13.060" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6860/V4</Name>
<Coord X="17.910" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0009</Name>
<SubId ID="11009"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.824" Y="-0.179" X="15.179"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0015</Name>
<SubId ID="11015"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.815" Y="6.182" X="15.756"></Coord>
<Dir Z="0.000" Y="1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_5</Name>
<SubId ID="16005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="2.959" X="15.545"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_4</Name>
<SubId ID="14004"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.297" Y="5.820" X="17.483"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_106</Name>
<SubId ID="2106"></SubId>
<Group>
<Name>undest_room_106</Name>
<BBox_Min Z="-0.300" Y="-0.075" X="2.690"></BBox_Min>
<BBox_Max Z="2.700" Y="2.329" X="13.060"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="2.870"></BBox_Min>
<BBox_Max Z="0.000" Y="2.149" X="12.880"></BBox_Max>
<Polygon>
<Name>p6861</Name>
<Vertex>
<Name>p6861/V1</Name>
<Coord X="2.870" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6861/V2</Name>
<Coord X="12.880" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6861/V3</Name>
<Coord X="12.880" Y="2.149" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6861/V4</Name>
<Coord X="2.870" Y="2.149" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0008</Name>
<SubId ID="11008"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.83" Y="-0.172" X="10.065"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0007</Name>
<SubId ID="11007"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.664" Y="-0.098" X="7.631"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0006</Name>
<SubId ID="11006"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.822" Y="-0.174" X="3.831"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_6</Name>
<SubId ID="16006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.101" X="11.249"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_7</Name>
<SubId ID="16007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.149" X="4.793"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_5</Name>
<SubId ID="14005"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.297" Y="0.388" X="12.880"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=2.7</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.500" Y="-0.151" X="0.000"></BBox_Min>
<BBox_Max Z="6.525" Y="6.156" X="2.870"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="2.690"></BBox_Max>
<Polygon>
<Name>p6561</Name>
<Vertex>
<Name>p6561/V1</Name>
<Coord X="2.690" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6561/V2</Name>
<Coord X="0.180" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6561/V3</Name>
<Coord X="0.180" Y="0.180" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6561/V4</Name>
<Coord X="2.690" Y="0.180" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0010</Name>
<SubId ID="11010"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.273" Y="-0.101" X="1.438"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0024</Name>
<SubId ID="11024"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.24" Y="6.118" X="1.428"></Coord>
<Dir Z="0.000" Y="1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0004</Name>
<SubId ID="11004"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.293" Y="1.312" X="-0.136"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0003</Name>
<SubId ID="11003"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.237" Y="4.225" X="-0.131"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_8</Name>
<SubId ID="16008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.074" Y="1.257" X="1.448"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_6</Name>
<SubId ID="14006"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.957" Y="5.820" X="1.431"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_202</Name>
<SubId ID="2202"></SubId>
<Group>
<Name>undest_room_202</Name>
<BBox_Min Z="2.500" Y="2.149" X="2.690"></BBox_Min>
<BBox_Max Z="5.400" Y="6.000" X="6.042"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="2.329" X="2.870"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="5.862"></BBox_Max>
<Polygon>
<Name>p6562</Name>
<Vertex>
<Name>p6562/V1</Name>
<Coord X="5.862" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6562/V2</Name>
<Coord X="2.870" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6562/V3</Name>
<Coord X="2.870" Y="2.329" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6562/V4</Name>
<Coord X="5.862" Y="2.329" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0023</Name>
<SubId ID="11023"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.268" Y="6.119000000000001" X="4.265"></Coord>
<Dir Z="0.000" Y="1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_9</Name>
<SubId ID="16009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.074" Y="4.004" X="4.425"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_13</Name>
<SubId ID="14013"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.978" Y="5.820" X="5.440"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_203</Name>
<SubId ID="2203"></SubId>
<Group>
<Name>undest_room_203</Name>
<BBox_Min Z="2.500" Y="2.149" X="5.862"></BBox_Min>
<BBox_Max Z="5.400" Y="6.000" X="9.571"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="2.329" X="6.042"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="9.391"></BBox_Max>
<Polygon>
<Name>p6563</Name>
<Vertex>
<Name>p6563/V1</Name>
<Coord X="9.391" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6563/V2</Name>
<Coord X="6.042" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6563/V3</Name>
<Coord X="6.042" Y="2.329" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6563/V4</Name>
<Coord X="9.391" Y="2.329" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0022</Name>
<SubId ID="11022"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.276" Y="6.117" X="7.697"></Coord>
<Dir Z="0.000" Y="1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_10</Name>
<SubId ID="16010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.074" Y="4.041" X="7.699"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_9</Name>
<SubId ID="14009"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.978" Y="5.820" X="9.067"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_204</Name>
<SubId ID="2204"></SubId>
<Group>
<Name>undest_room_204</Name>
<BBox_Min Z="2.500" Y="2.149" X="9.391"></BBox_Min>
<BBox_Max Z="5.400" Y="6.000" X="13.060"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="2.329" X="9.571"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="12.880"></BBox_Max>
<Polygon>
<Name>p6564</Name>
<Vertex>
<Name>p6564/V1</Name>
<Coord X="12.880" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6564/V2</Name>
<Coord X="9.571" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6564/V3</Name>
<Coord X="9.571" Y="2.329" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6564/V4</Name>
<Coord X="12.880" Y="2.329" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0021</Name>
<SubId ID="11021"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.267" Y="6.117" X="11.189"></Coord>
<Dir Z="0.000" Y="1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_11</Name>
<SubId ID="16011"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.074" Y="4.001" X="11.214"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_10</Name>
<SubId ID="14010"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.978" Y="5.820" X="12.409"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_205</Name>
<SubId ID="2205"></SubId>
<Group>
<Name>undest_room_205</Name>
<BBox_Min Z="2.500" Y="-0.151" X="12.880"></BBox_Min>
<BBox_Max Z="5.400" Y="6.156" X="18.000"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="0.180" X="13.060"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="17.910"></BBox_Max>
<Polygon>
<Name>p6565</Name>
<Vertex>
<Name>p6565/V1</Name>
<Coord X="17.910" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6565/V2</Name>
<Coord X="13.060" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6565/V3</Name>
<Coord X="13.060" Y="0.180" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6565/V4</Name>
<Coord X="17.910" Y="0.180" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0013</Name>
<SubId ID="11013"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.251" Y="-0.105" X="15.501"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0020</Name>
<SubId ID="11020"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.285" Y="6.115" X="15.437"></Coord>
<Dir Z="0.000" Y="1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_12</Name>
<SubId ID="16012"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.074" Y="2.988" X="15.457"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_11</Name>
<SubId ID="14011"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.978" Y="5.820" X="17.483"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_206</Name>
<SubId ID="2206"></SubId>
<Group>
<Name>undest_room_206</Name>
<BBox_Min Z="2.500" Y="0.000" X="2.690"></BBox_Min>
<BBox_Max Z="5.400" Y="2.329" X="13.060"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="0.180" X="2.870"></BBox_Min>
<BBox_Max Z="2.700" Y="2.149" X="12.880"></BBox_Max>
<Polygon>
<Name>p6566</Name>
<Vertex>
<Name>p6566/V1</Name>
<Coord X="12.880" Y="2.149" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6566/V2</Name>
<Coord X="2.870" Y="2.149" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6566/V3</Name>
<Coord X="2.870" Y="0.180" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6566/V4</Name>
<Coord X="12.880" Y="0.180" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0012</Name>
<SubId ID="11012"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.294" Y="-0.1" X="10.374"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0011</Name>
<SubId ID="11011"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.292" Y="-0.097" X="4.113"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_13</Name>
<SubId ID="16013"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.074" Y="1.182" X="11.345"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_14</Name>
<SubId ID="16014"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.074" Y="1.181" X="4.484"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_12</Name>
<SubId ID="14012"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.978" Y="0.388" X="12.880"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_3</Name>
<Comment>base_height=5.4</Comment>
<Switch>
<Name>SW_room_301</Name>
<SubId ID="2301"></SubId>
<Group>
<Name>undest_room_301</Name>
<BBox_Min Z="5.200" Y="-0.737" X="-0.203"></BBox_Min>
<BBox_Max Z="8.671" Y="6.741" X="18.318"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="5.400" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="5.400" Y="5.820" X="17.910"></BBox_Max>
<Polygon>
<Name>p5552</Name>
<Vertex>
<Name>p5552/V1</Name>
<Coord X="0.180" Y="0.180" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p5552/V2</Name>
<Coord X="17.910" Y="0.180" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p5552/V3</Name>
<Coord X="17.910" Y="5.820" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p5552/V4</Name>
<Coord X="0.180" Y="5.820" Z="5.400"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0014</Name>
<SubId ID="11014"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="7.70026" Y="0.461" X="9.663"></Coord>
<Dir Z="0.866" Y="-0.500" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0025</Name>
<SubId ID="11025"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="7.68926" Y="5.54" X="5.296"></Coord>
<Dir Z="0.866" Y="0.500" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_15</Name>
<SubId ID="16015"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="6.010" Y="3.102" X="4.973"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_16</Name>
<SubId ID="16016"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="6.010" Y="3.117" X="12.796"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_7</Name>
<SubId ID="14007"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="7.391" Y="2.964" X="17.910"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_8</Name>
<SubId ID="14008"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="5.638" Y="5.820" X="1.431"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_4</Name>
<Comment>base_height=8.67</Comment>
<Switch>
<Name>SW_room_401</Name>
<SubId ID="2401"></SubId>
<Group>
<Name>undest_room_401</Name>
<BBox_Min Z="6.415" Y="-0.737" X="-0.203"></BBox_Min>
<BBox_Max Z="8.671" Y="6.741" X="18.318"></BBox_Max>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="2.250" Y="-0.100" X="0.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="7.052" X="1.977"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="7.052" X="6.644"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="7.052" X="11.310"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="7.052" X="15.977"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_5</Name>
<SubId ID="15005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="4.500" X="19.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_6</Name>
<SubId ID="15006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="2.000" X="19.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_7</Name>
<SubId ID="15007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.070" X="16.000"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_8</Name>
<SubId ID="15008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.070" X="11.333"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_9</Name>
<SubId ID="15009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.070" X="6.667"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_10</Name>
<SubId ID="15010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.070" X="2.000"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_11</Name>
<SubId ID="15011"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="1.500" X="-1.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_12</Name>
<SubId ID="15012"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="4.000" X="-1.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.550" Y="2.429" X="8.882"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_2</Name>
<SubId ID="27002"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="3.231" Y="2.429" X="8.882"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>