441 lines
22 KiB
XML
Executable File
441 lines
22 KiB
XML
Executable File
<?xml version="1.0" ?>
|
|
<!--fltHdrLastDate Mon Jan 10 13:11:58 2022 - PostProcessed by SLTE $Rev: 56086 $-->
|
|
<STREIF>
|
|
<Header>
|
|
<Group>
|
|
<Name>bldg_3170</Name>
|
|
<ModelId Id="1170"></ModelId>
|
|
<BBox_Min Z="-0.300" Y="-0.378" X="-0.075"></BBox_Min>
|
|
<BBox_Max Z="3.977" Y="6.075" X="12.075"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="0.000" X="0.000"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="6.000" X="12.000"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p2878</Name>
|
|
<Vertex>
|
|
<Name>p2878/V1</Name>
|
|
<Coord X="12.000" Y="6.000" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2878/V2</Name>
|
|
<Coord X="0.000" Y="6.000" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2878/V3</Name>
|
|
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2878/V4</Name>
|
|
<Coord X="12.000" Y="0.000" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<Group>
|
|
<Name>floor_1</Name>
|
|
<Comment>base_height=0.00</Comment>
|
|
<Switch>
|
|
<Name>SW_room_101</Name>
|
|
<SubId ID="2101"></SubId>
|
|
<Group>
|
|
<Name>undest_room_101</Name>
|
|
<BBox_Min Z="-0.300" Y="-0.348" X="0.000"></BBox_Min>
|
|
<BBox_Max Z="3.161" Y="3.095" X="7.713"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="0.180" X="0.180"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="2.915" X="7.533"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p2865</Name>
|
|
<Vertex>
|
|
<Name>p2865/V1</Name>
|
|
<Coord X="0.180" Y="1.682" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2865/V2</Name>
|
|
<Coord X="0.180" Y="0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2865/V3</Name>
|
|
<Coord X="7.533" Y="0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2865/V4</Name>
|
|
<Coord X="7.533" Y="2.915" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2865/V5</Name>
|
|
<Coord X="4.755" Y="2.915" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2865/V6</Name>
|
|
<Coord X="4.755" Y="1.682" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0004</Name>
|
|
<SubId ID="11004"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.287" Y="-0.121" X="6.362"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0003</Name>
|
|
<SubId ID="11003"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.047" Y="-0.193" X="2.403"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0009</Name>
|
|
<SubId ID="11009"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.215" Y="0.931" X="-0.10200000000000001"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_1</Name>
|
|
<SubId ID="16001"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="0.942" X="2.278"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_2</Name>
|
|
<SubId ID="16002"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="1.650" X="6.816"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_1</Name>
|
|
<SubId ID="14001"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.200" Y="1.043" X="0.180"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_102</Name>
|
|
<SubId ID="2102"></SubId>
|
|
<Group>
|
|
<Name>undest_room_102</Name>
|
|
<BBox_Min Z="-0.300" Y="1.682" X="-0.075"></BBox_Min>
|
|
<BBox_Max Z="2.875" Y="6.075" X="4.755"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="1.862" X="0.180"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="5.820" X="4.575"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p2866</Name>
|
|
<Vertex>
|
|
<Name>p2866/V1</Name>
|
|
<Coord X="0.180" Y="1.862" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2866/V2</Name>
|
|
<Coord X="4.575" Y="1.862" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2866/V3</Name>
|
|
<Coord X="4.575" Y="5.820" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2866/V4</Name>
|
|
<Coord X="0.180" Y="5.820" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0008</Name>
|
|
<SubId ID="11008"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.042" Y="4.681" X="-0.17099999999999999"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0002</Name>
|
|
<SubId ID="11002"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.049" Y="6.19" X="3.171"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_3</Name>
|
|
<SubId ID="16003"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="3.879" X="2.428"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_2</Name>
|
|
<SubId ID="14002"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.200" Y="5.046" X="0.180"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_103</Name>
|
|
<SubId ID="2103"></SubId>
|
|
<Group>
|
|
<Name>undest_room_103</Name>
|
|
<BBox_Min Z="-0.300" Y="2.915" X="4.575"></BBox_Min>
|
|
<BBox_Max Z="2.875" Y="6.075" X="12.075"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="3.095" X="4.755"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="5.820" X="11.820"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p2867</Name>
|
|
<Vertex>
|
|
<Name>p2867/V1</Name>
|
|
<Coord X="11.820" Y="5.820" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2867/V2</Name>
|
|
<Coord X="4.755" Y="5.820" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2867/V3</Name>
|
|
<Coord X="4.755" Y="3.095" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2867/V4</Name>
|
|
<Coord X="11.820" Y="3.095" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0001</Name>
|
|
<SubId ID="11001"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="1.593" Y="6.182" X="9.018"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0007</Name>
|
|
<SubId ID="11007"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.049" Y="3.809" X="12.202"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_4</Name>
|
|
<SubId ID="16004"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="4.478" X="8.240"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_3</Name>
|
|
<SubId ID="14003"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.200" Y="4.463" X="4.755"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_104</Name>
|
|
<SubId ID="2104"></SubId>
|
|
<Group>
|
|
<Name>undest_room_104</Name>
|
|
<BBox_Min Z="-0.300" Y="-0.348" X="7.533"></BBox_Min>
|
|
<BBox_Max Z="2.790" Y="3.095" X="12.075"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="0.180" X="7.713"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="2.915" X="11.820"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p2868</Name>
|
|
<Vertex>
|
|
<Name>p2868/V1</Name>
|
|
<Coord X="11.820" Y="2.915" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2868/V2</Name>
|
|
<Coord X="7.713" Y="2.915" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2868/V3</Name>
|
|
<Coord X="7.713" Y="0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2868/V4</Name>
|
|
<Coord X="11.820" Y="0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0005</Name>
|
|
<SubId ID="11005"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="1.889" Y="-0.126" X="9.638"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0006</Name>
|
|
<SubId ID="11006"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.045" Y="0.742" X="12.190999999999999"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_5</Name>
|
|
<SubId ID="16005"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="1.627" X="9.794"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_4</Name>
|
|
<SubId ID="14004"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.200" Y="2.476" X="11.820"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
</Group>
|
|
<Group>
|
|
<Name>floor_2</Name>
|
|
<Comment>base_height=2.7</Comment>
|
|
<Switch>
|
|
<Name>SW_room_201</Name>
|
|
<SubId ID="2201"></SubId>
|
|
<Group>
|
|
<Name>undest_room_201</Name>
|
|
<BBox_Min Z="2.494" Y="-0.378" X="0.000"></BBox_Min>
|
|
<BBox_Max Z="3.977" Y="6.000" X="12.000"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="2.700" Y="0.000" X="0.180"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="5.820" X="11.820"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p2558</Name>
|
|
<Vertex>
|
|
<Name>p2558/V1</Name>
|
|
<Coord X="0.180" Y="0.000" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2558/V2</Name>
|
|
<Coord X="11.820" Y="0.000" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2558/V3</Name>
|
|
<Coord X="11.820" Y="5.820" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2558/V4</Name>
|
|
<Coord X="0.180" Y="5.820" Z="2.700"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_6</Name>
|
|
<SubId ID="16006"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="3.010" Y="3.079" X="9.204"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_7</Name>
|
|
<SubId ID="16007"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="3.010" Y="3.136" X="2.575"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>ZEG_MOD_AP_1</Name>
|
|
<SubId ID="12001"></SubId>
|
|
<Model NAME="ZEG_01.flt"></Model>
|
|
<Coord Z="2.250" Y="-0.100" X="0.100"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_1</Name>
|
|
<SubId ID="15001"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="-1.000" X="2.500"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_2</Name>
|
|
<SubId ID="15002"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="-1.000" X="5.761"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_3</Name>
|
|
<SubId ID="15003"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="-1.000" X="9.500"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_4</Name>
|
|
<SubId ID="15004"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="7.000" X="2.500"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_5</Name>
|
|
<SubId ID="15005"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="7.000" X="9.500"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_6</Name>
|
|
<SubId ID="15006"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="7.000" X="5.761"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_7</Name>
|
|
<SubId ID="15007"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="4.000" X="-1.000"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_8</Name>
|
|
<SubId ID="15008"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="2.000" X="-1.000"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_9</Name>
|
|
<SubId ID="15009"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="2.000" X="13.000"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_10</Name>
|
|
<SubId ID="15010"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="3.999" X="13.000"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>BDI_P_1</Name>
|
|
<SubId ID="27001"></SubId>
|
|
<Model NAME="BDI.flt"></Model>
|
|
<Coord Z="0.550" Y="2.815" X="5.569"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Header>
|
|
</STREIF> |