Files
2026-10-23 16:13:31 +00:00

361 lines
18 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Mon Jan 10 16:31:31 2022 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_3189</Name>
<ModelId Id="1189"></ModelId>
<BBox_Min Z="-0.300" Y="-1.070" X="-1.070"></BBox_Min>
<BBox_Max Z="3.660" Y="13.058" X="7.070"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.000" X="0.000"></BBox_Min>
<BBox_Max Z="0.000" Y="11.988" X="6.000"></BBox_Max>
<Polygon>
<Name>p956</Name>
<Vertex>
<Name>p956/V1</Name>
<Coord X="6.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p956/V2</Name>
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p956/V3</Name>
<Coord X="0.000" Y="11.988" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p956/V4</Name>
<Coord X="6.000" Y="11.988" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0.00</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.300" Y="-0.215" X="-0.187"></BBox_Min>
<BBox_Max Z="3.781" Y="12.177" X="6.385"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="0.000" Y="11.946" X="5.820"></BBox_Max>
<Polygon>
<Name>p963</Name>
<Vertex>
<Name>p963/V1</Name>
<Coord X="0.180" Y="4.867" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p963/V2</Name>
<Coord X="2.873" Y="4.867" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p963/V3</Name>
<Coord X="2.873" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p963/V4</Name>
<Coord X="5.820" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p963/V5</Name>
<Coord X="5.820" Y="11.808" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p963/V6</Name>
<Coord X="4.140" Y="11.808" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p963/V7</Name>
<Coord X="4.140" Y="11.946" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p963/V8</Name>
<Coord X="3.010" Y="11.946" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p963/V9</Name>
<Coord X="3.010" Y="11.808" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p963/V10</Name>
<Coord X="0.180" Y="11.808" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0005</Name>
<SubId ID="11005"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.165" Y="12.155999999999999" X="2.129"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0004</Name>
<SubId ID="11004"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.465" Y="12.081" X="3.229"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0006</Name>
<SubId ID="11006"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.17" Y="9.763" X="-0.188"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0009</Name>
<SubId ID="11009"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.007" Y="-0.137" X="4.604"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.14" Y="1.694" X="6.191000000000001"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.383" Y="5.797" X="6.114"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0003</Name>
<SubId ID="11003"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.145" Y="8.704" X="6.194"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="2.433" X="4.346"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="8.337" X="3.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.300" Y="11.808" X="3.512"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_102</Name>
<SubId ID="2102"></SubId>
<Group>
<Name>undest_room_102</Name>
<BBox_Min Z="-0.300" Y="-0.215" X="-0.187"></BBox_Min>
<BBox_Max Z="3.781" Y="4.867" X="2.873"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="0.000" Y="4.687" X="2.693"></BBox_Max>
<Polygon>
<Name>p966</Name>
<Vertex>
<Name>p966/V1</Name>
<Coord X="0.180" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p966/V2</Name>
<Coord X="2.693" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p966/V3</Name>
<Coord X="2.693" Y="4.687" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p966/V4</Name>
<Coord X="0.180" Y="4.687" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0007</Name>
<SubId ID="11007"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.165" Y="3.79" X="-0.193"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0008</Name>
<SubId ID="11008"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.466" Y="-0.139" X="1.734"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_3</Name>
<SubId ID="16003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="2.433" X="1.436"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_2</Name>
<SubId ID="14002"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.300" Y="4.687" X="1.421"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=3.78</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.600" Y="-0.215" X="-0.187"></BBox_Min>
<BBox_Max Z="3.781" Y="12.177" X="6.415"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.808" Y="-0.215" X="-0.185"></BBox_Min>
<BBox_Max Z="2.808" Y="12.177" X="6.234"></BBox_Max>
<Polygon>
<Name>p967</Name>
<Vertex>
<Name>p967/V1</Name>
<Coord X="6.234" Y="12.177" Z="2.808"></Coord>
</Vertex>
<Vertex>
<Name>p967/V2</Name>
<Coord X="-0.185" Y="12.177" Z="2.808"></Coord>
</Vertex>
<Vertex>
<Name>p967/V3</Name>
<Coord X="-0.185" Y="-0.215" Z="2.808"></Coord>
</Vertex>
<Vertex>
<Name>p967/V4</Name>
<Coord X="6.234" Y="-0.215" Z="2.808"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>subroom_1</Name>
<BBox_Min Z="2.808" Y="-0.215" X="-0.185"></BBox_Min>
<BBox_Max Z="3.781" Y="12.177" X="6.234"></BBox_Max>
</Group>
<External_Reference>
<Name>IPS_IN_AP_4</Name>
<SubId ID="16004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.594" Y="5.981" X="3.025"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="3.200" Y="-0.100" X="0.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="1.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="4.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="2.000" X="7.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="5.994" X="7.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_5</Name>
<SubId ID="15005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="9.988" X="7.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_6</Name>
<SubId ID="15006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="12.988" X="4.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_7</Name>
<SubId ID="15007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="12.988" X="1.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_8</Name>
<SubId ID="15008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="9.988" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_9</Name>
<SubId ID="15009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="5.994" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_10</Name>
<SubId ID="15010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="2.000" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.499" Y="5.591" X="0.303"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>