Files
2026-10-23 16:13:31 +00:00

984 lines
51 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Fri Dec 03 14:04:12 2021 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_3230</Name>
<ModelId Id="1230"></ModelId>
<BBox_Min Z="-0.300" Y="-1.070" X="-1.070"></BBox_Min>
<BBox_Max Z="11.332" Y="7.070" X="19.110"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.000" X="0.000"></BBox_Min>
<BBox_Max Z="0.000" Y="6.000" X="18.040"></BBox_Max>
<Polygon>
<Name>p4023</Name>
<Vertex>
<Name>p4023/V1</Name>
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4023/V2</Name>
<Coord X="18.040" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4023/V3</Name>
<Coord X="18.040" Y="6.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4023/V4</Name>
<Coord X="0.000" Y="6.000" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0.00</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.300" Y="-0.075" X="0.000"></BBox_Min>
<BBox_Max Z="2.700" Y="6.075" X="6.581"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="0.090"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="6.401"></BBox_Max>
<Polygon>
<Name>p4033</Name>
<Vertex>
<Name>p4033/V1</Name>
<Coord X="6.401" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4033/V2</Name>
<Coord X="0.090" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4033/V3</Name>
<Coord X="0.090" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4033/V4</Name>
<Coord X="6.401" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0005</Name>
<SubId ID="11005"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.878" Y="6.1290000000000004" X="1.304"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0004</Name>
<SubId ID="11004"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.04" Y="6.197" X="3.635"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0013</Name>
<SubId ID="11013"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.149" Y="-0.183" X="3.081"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.170" Y="0.759" X="0.090"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.000" X="3.246"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_102</Name>
<SubId ID="2102"></SubId>
<Group>
<Name>undest_room_102</Name>
<BBox_Min Z="-0.300" Y="-0.075" X="6.401"></BBox_Min>
<BBox_Max Z="2.700" Y="6.000" X="12.528"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="6.581"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="12.143"></BBox_Max>
<Polygon>
<Name>p4034</Name>
<Vertex>
<Name>p4034/V1</Name>
<Coord X="12.143" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4034/V2</Name>
<Coord X="6.581" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4034/V3</Name>
<Coord X="6.581" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4034/V4</Name>
<Coord X="12.143" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0003</Name>
<SubId ID="11003"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.276" Y="6.132000000000001" X="9.316"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0014</Name>
<SubId ID="11014"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.147" Y="-0.181" X="9.11"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_2</Name>
<SubId ID="14002"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.200" Y="5.820" X="9.452"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.000" X="9.362"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_103</Name>
<SubId ID="2103"></SubId>
<Group>
<Name>undest_room_103</Name>
<BBox_Min Z="-0.300" Y="0.000" X="12.143"></BBox_Min>
<BBox_Max Z="3.822" Y="6.000" X="15.008"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="12.323"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="14.828"></BBox_Max>
<Polygon>
<Name>p4035</Name>
<Vertex>
<Name>p4035/V1</Name>
<Coord X="14.828" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4035/V2</Name>
<Coord X="12.323" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4035/V3</Name>
<Coord X="12.323" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4035/V4</Name>
<Coord X="14.828" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.289" Y="6.125" X="13.539"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0015</Name>
<SubId ID="11015"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.297" Y="-0.107" X="13.516"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_3</Name>
<SubId ID="16003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.500" X="13.576"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_4</Name>
<SubId ID="16004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="1.560" Y="5.248" X="13.576"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_104</Name>
<SubId ID="2104"></SubId>
<Group>
<Name>undest_room_104</Name>
<BBox_Min Z="-0.300" Y="-0.151" X="14.624"></BBox_Min>
<BBox_Max Z="2.700" Y="6.156" X="18.040"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="15.008"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="17.895"></BBox_Max>
<Polygon>
<Name>p4036</Name>
<Vertex>
<Name>p4036/V1</Name>
<Coord X="17.895" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4036/V2</Name>
<Coord X="15.008" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4036/V3</Name>
<Coord X="15.008" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4036/V4</Name>
<Coord X="17.895" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.033" Y="6.183000000000001" X="16.646"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0016</Name>
<SubId ID="11016"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.385" Y="-0.113" X="16.422"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_5</Name>
<SubId ID="16005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.000" X="16.451"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_3</Name>
<SubId ID="14003"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.200" Y="0.180" X="16.522"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=2.7</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.500" Y="0.000" X="0.000"></BBox_Min>
<BBox_Max Z="5.400" Y="6.000" X="6.581"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="0.180" X="0.090"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="6.401"></BBox_Max>
<Polygon>
<Name>p4046</Name>
<Vertex>
<Name>p4046/V1</Name>
<Coord X="6.401" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p4046/V2</Name>
<Coord X="0.090" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p4046/V3</Name>
<Coord X="0.090" Y="0.180" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p4046/V4</Name>
<Coord X="6.401" Y="0.180" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0009</Name>
<SubId ID="11009"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.52" Y="6.1290000000000004" X="3.349"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0017</Name>
<SubId ID="11017"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.594" Y="-0.107" X="3.364"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_6</Name>
<SubId ID="16006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.000" Y="3.000" X="3.246"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_13</Name>
<SubId ID="14013"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.900" Y="3.055" X="6.401"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_202</Name>
<SubId ID="2202"></SubId>
<Group>
<Name>undest_room_202</Name>
<BBox_Min Z="2.500" Y="0.000" X="6.401"></BBox_Min>
<BBox_Max Z="5.400" Y="6.000" X="12.528"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="0.180" X="6.581"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="12.143"></BBox_Max>
<Polygon>
<Name>p4047</Name>
<Vertex>
<Name>p4047/V1</Name>
<Coord X="12.143" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p4047/V2</Name>
<Coord X="6.581" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p4047/V3</Name>
<Coord X="6.581" Y="0.180" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p4047/V4</Name>
<Coord X="12.143" Y="0.180" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0008</Name>
<SubId ID="11008"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.477" Y="6.131" X="9.299"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0018</Name>
<SubId ID="11018"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.6" Y="-0.106" X="9.397"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_7</Name>
<SubId ID="16007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.000" Y="3.000" X="9.362"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_11</Name>
<SubId ID="14011"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.900" Y="2.992" X="12.143"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_203</Name>
<SubId ID="2203"></SubId>
<Group>
<Name>undest_room_203</Name>
<BBox_Min Z="2.500" Y="0.000" X="12.143"></BBox_Min>
<BBox_Max Z="6.522" Y="6.000" X="15.008"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="0.180" X="12.323"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="14.828"></BBox_Max>
<Polygon>
<Name>p4048</Name>
<Vertex>
<Name>p4048/V1</Name>
<Coord X="14.828" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p4048/V2</Name>
<Coord X="12.323" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p4048/V3</Name>
<Coord X="12.323" Y="0.180" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p4048/V4</Name>
<Coord X="14.828" Y="0.180" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0007</Name>
<SubId ID="11007"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.544" Y="6.128" X="13.526"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0019</Name>
<SubId ID="11019"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.627" Y="-0.107" X="14.012"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_4</Name>
<SubId ID="14004"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="3.320" Y="5.820" X="14.282"></Coord>
<Dir Z="-0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_8</Name>
<SubId ID="16008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.000" Y="1.233" X="13.576"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_9</Name>
<SubId ID="16009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="4.260" Y="5.248" X="13.576"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_204</Name>
<SubId ID="2204"></SubId>
<Group>
<Name>undest_room_204</Name>
<BBox_Min Z="2.500" Y="-0.151" X="14.624"></BBox_Min>
<BBox_Max Z="5.400" Y="6.156" X="18.040"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="0.180" X="15.008"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="17.895"></BBox_Max>
<Polygon>
<Name>p4049</Name>
<Vertex>
<Name>p4049/V1</Name>
<Coord X="17.895" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p4049/V2</Name>
<Coord X="15.008" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p4049/V3</Name>
<Coord X="15.008" Y="0.180" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p4049/V4</Name>
<Coord X="17.895" Y="0.180" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0006</Name>
<SubId ID="11006"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.52" Y="6.114" X="16.364"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0020</Name>
<SubId ID="11020"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.572" Y="-0.109" X="16.432"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_5</Name>
<SubId ID="14005"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.900" Y="0.180" X="16.522"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_10</Name>
<SubId ID="16010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.000" Y="3.000" X="16.451"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_3</Name>
<Comment>base_height=5.7</Comment>
<Switch>
<Name>SW_room_301</Name>
<SubId ID="2301"></SubId>
<Group>
<Name>undest_room_301</Name>
<BBox_Min Z="5.200" Y="0.000" X="0.000"></BBox_Min>
<BBox_Max Z="8.100" Y="6.000" X="6.581"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="5.400" Y="0.180" X="0.090"></BBox_Min>
<BBox_Max Z="5.400" Y="5.820" X="6.401"></BBox_Max>
<Polygon>
<Name>p4061</Name>
<Vertex>
<Name>p4061/V1</Name>
<Coord X="6.401" Y="5.820" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p4061/V2</Name>
<Coord X="0.090" Y="5.820" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p4061/V3</Name>
<Coord X="0.090" Y="0.180" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p4061/V4</Name>
<Coord X="6.401" Y="0.180" Z="5.400"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0011</Name>
<SubId ID="11011"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="6.213" Y="6.128" X="3.382"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0021</Name>
<SubId ID="11021"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="6.318" Y="-0.108" X="3.377"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_11</Name>
<SubId ID="16011"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="5.700" Y="3.000" X="3.246"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_6</Name>
<SubId ID="14006"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="7.570" Y="0.759" X="0.090"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_302</Name>
<SubId ID="2302"></SubId>
<Group>
<Name>undest_room_302</Name>
<BBox_Min Z="5.200" Y="0.000" X="6.401"></BBox_Min>
<BBox_Max Z="8.100" Y="6.000" X="12.528"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="5.400" Y="0.180" X="6.581"></BBox_Min>
<BBox_Max Z="5.400" Y="5.820" X="12.143"></BBox_Max>
<Polygon>
<Name>p4062</Name>
<Vertex>
<Name>p4062/V1</Name>
<Coord X="12.143" Y="5.820" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p4062/V2</Name>
<Coord X="6.581" Y="5.820" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p4062/V3</Name>
<Coord X="6.581" Y="0.180" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p4062/V4</Name>
<Coord X="12.143" Y="0.180" Z="5.400"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0022</Name>
<SubId ID="11022"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="6.326" Y="-0.107" X="9.408"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_12</Name>
<SubId ID="16012"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="5.700" Y="3.000" X="9.362"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_10</Name>
<SubId ID="14010"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="7.400" Y="2.537" X="6.581"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_303</Name>
<SubId ID="2303"></SubId>
<Group>
<Name>undest_room_303</Name>
<BBox_Min Z="5.200" Y="0.000" X="12.143"></BBox_Min>
<BBox_Max Z="9.222" Y="6.000" X="15.008"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="5.400" Y="0.180" X="12.323"></BBox_Min>
<BBox_Max Z="5.400" Y="5.820" X="14.828"></BBox_Max>
<Polygon>
<Name>p4064</Name>
<Vertex>
<Name>p4064/V1</Name>
<Coord X="14.828" Y="5.820" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p4064/V2</Name>
<Coord X="12.323" Y="5.820" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p4064/V3</Name>
<Coord X="12.323" Y="0.180" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p4064/V4</Name>
<Coord X="14.828" Y="0.180" Z="5.400"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0023</Name>
<SubId ID="11023"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="6.169" Y="-0.105" X="13.889"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_13</Name>
<SubId ID="16013"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="5.700" Y="1.419" X="13.576"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_7</Name>
<SubId ID="14007"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="6.020" Y="5.820" X="14.282"></Coord>
<Dir Z="-0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_14</Name>
<SubId ID="16014"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="6.960" Y="5.248" X="13.576"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_304</Name>
<SubId ID="2304"></SubId>
<Group>
<Name>undest_room_304</Name>
<BBox_Min Z="5.200" Y="-0.151" X="14.624"></BBox_Min>
<BBox_Max Z="8.100" Y="6.156" X="18.040"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="5.400" Y="0.180" X="15.008"></BBox_Min>
<BBox_Max Z="5.400" Y="5.820" X="17.895"></BBox_Max>
<Polygon>
<Name>p4063</Name>
<Vertex>
<Name>p4063/V1</Name>
<Coord X="17.895" Y="5.820" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p4063/V2</Name>
<Coord X="15.008" Y="5.820" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p4063/V3</Name>
<Coord X="15.008" Y="0.180" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p4063/V4</Name>
<Coord X="17.895" Y="0.180" Z="5.400"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0010</Name>
<SubId ID="11010"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="6.214" Y="6.113" X="16.385"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_15</Name>
<SubId ID="16015"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="5.700" Y="3.000" X="16.451"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_8</Name>
<SubId ID="14008"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="7.400" Y="0.180" X="16.522"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_4</Name>
<Comment>base_height=8.1</Comment>
<Switch>
<Name>SW_room_401</Name>
<SubId ID="2401"></SubId>
<Group>
<Name>undest_room_401</Name>
<BBox_Min Z="7.900" Y="-0.737" X="0.000"></BBox_Min>
<BBox_Max Z="11.332" Y="6.741" X="18.279"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="8.100" Y="0.180" X="0.090"></BBox_Min>
<BBox_Max Z="8.100" Y="5.820" X="17.895"></BBox_Max>
<Polygon>
<Name>p4067</Name>
<Vertex>
<Name>p4067/V1</Name>
<Coord X="17.895" Y="5.820" Z="8.100"></Coord>
</Vertex>
<Vertex>
<Name>p4067/V2</Name>
<Coord X="0.090" Y="5.820" Z="8.100"></Coord>
</Vertex>
<Vertex>
<Name>p4067/V3</Name>
<Coord X="0.090" Y="0.180" Z="8.100"></Coord>
</Vertex>
<Vertex>
<Name>p4067/V4</Name>
<Coord X="17.895" Y="0.180" Z="8.100"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0012</Name>
<SubId ID="11012"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="10.656" Y="5.308000000000001" X="10.08"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0024</Name>
<SubId ID="11024"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="10.84926" Y="0.871" X="9.729"></Coord>
<Dir Z="0.866" Y="0.500" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_16</Name>
<SubId ID="16016"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="8.400" Y="3.000" X="6.220"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_9</Name>
<SubId ID="14009"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="10.270" Y="3.000" X="0.090"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_17</Name>
<SubId ID="16017"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="8.400" Y="3.000" X="16.361"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_12</Name>
<SubId ID="14012"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="9.000" Y="5.820" X="13.416"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_5</Name>
<Comment>base_height=11.3</Comment>
<Switch>
<Name>SW_room_501</Name>
<SubId ID="2501"></SubId>
<Group>
<Name>undest_room_501</Name>
<BBox_Min Z="9.076" Y="-0.737" X="0.000"></BBox_Min>
<BBox_Max Z="11.332" Y="6.741" X="18.279"></BBox_Max>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="2.250" Y="-0.100" X="0.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.500" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.500" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="2.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="6.847"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_5</Name>
<SubId ID="15005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="11.193"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_6</Name>
<SubId ID="15006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="15.540"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_7</Name>
<SubId ID="15007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.500" X="19.040"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_8</Name>
<SubId ID="15008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.500" X="19.040"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_9</Name>
<SubId ID="15009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.000" X="15.540"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_10</Name>
<SubId ID="15010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.000" X="11.193"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_11</Name>
<SubId ID="15011"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.000" X="6.847"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_12</Name>
<SubId ID="15012"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.000" X="2.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="3.000" Y="5.719" X="9.561"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_2</Name>
<SubId ID="27002"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="5.700" Y="5.729" X="10.678"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_3</Name>
<SubId ID="27003"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.625" Y="3.059" X="12.049"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>