Files
2026-10-23 16:13:31 +00:00

768 lines
40 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Mon Dec 13 16:25:09 2021 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_3238</Name>
<ModelId Id="1238"></ModelId>
<BBox_Min Z="-0.300" Y="-1.140" X="-1.140"></BBox_Min>
<BBox_Max Z="8.630" Y="7.122" X="13.140"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.000" X="0.000"></BBox_Min>
<BBox_Max Z="0.000" Y="6.000" X="12.000"></BBox_Max>
<Polygon>
<Name>p6580</Name>
<Vertex>
<Name>p6580/V1</Name>
<Coord X="12.000" Y="6.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6580/V2</Name>
<Coord X="0.000" Y="6.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6580/V3</Name>
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6580/V4</Name>
<Coord X="12.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0.00</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.300" Y="-0.134" X="-0.072"></BBox_Min>
<BBox_Max Z="3.848" Y="6.134" X="8.126"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="7.946"></BBox_Max>
<Polygon>
<Name>p6606</Name>
<Vertex>
<Name>p6606/V1</Name>
<Coord X="7.946" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6606/V2</Name>
<Coord X="7.946" Y="2.076" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6606/V3</Name>
<Coord X="2.860" Y="2.076" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6606/V4</Name>
<Coord X="2.860" Y="1.892" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6606/V5</Name>
<Coord X="2.680" Y="1.892" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6606/V6</Name>
<Coord X="2.680" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6606/V7</Name>
<Coord X="0.180" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6606/V8</Name>
<Coord X="0.180" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0020</Name>
<SubId ID="11020"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.331" Y="6.122" X="1.408"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.277" Y="-0.123" X="6.341"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.019" Y="-0.184" X="3.549"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0013</Name>
<SubId ID="11013"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.021" Y="1.547" X="-0.216"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0012</Name>
<SubId ID="11012"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.231" Y="4.061" X="-0.134"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.089" X="2.177"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_102</Name>
<SubId ID="2102"></SubId>
<Group>
<Name>undest_room_102</Name>
<BBox_Min Z="-0.300" Y="2.076" X="2.680"></BBox_Min>
<BBox_Max Z="2.690" Y="6.072" X="6.087"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="2.256" X="2.860"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="5.907"></BBox_Max>
<Polygon>
<Name>p6607</Name>
<Vertex>
<Name>p6607/V1</Name>
<Coord X="5.907" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6607/V2</Name>
<Coord X="2.860" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6607/V3</Name>
<Coord X="2.860" Y="2.256" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6607/V4</Name>
<Coord X="5.907" Y="2.256" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0019</Name>
<SubId ID="11019"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.093" Y="6.194" X="4.728"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.937" X="4.365"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.200" Y="5.820" X="5.396"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_103</Name>
<SubId ID="2103"></SubId>
<Group>
<Name>undest_room_103</Name>
<BBox_Min Z="-0.300" Y="2.076" X="5.907"></BBox_Min>
<BBox_Max Z="2.690" Y="6.134" X="12.072"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="2.256" X="6.087"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="11.820"></BBox_Max>
<Polygon>
<Name>p6608</Name>
<Vertex>
<Name>p6608/V1</Name>
<Coord X="6.087" Y="2.256" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6608/V2</Name>
<Coord X="11.820" Y="2.256" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6608/V3</Name>
<Coord X="11.820" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6608/V4</Name>
<Coord X="6.087" Y="5.820" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0018</Name>
<SubId ID="11018"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.918" Y="6.118" X="6.65"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0017</Name>
<SubId ID="11017"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.1" Y="6.1930000000000005" X="8.898"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0016</Name>
<SubId ID="11016"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.226" Y="6.122" X="10.209"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0009</Name>
<SubId ID="11009"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.022" Y="3.612" X="12.17"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_3</Name>
<SubId ID="16003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.967" X="8.838"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_2</Name>
<SubId ID="14002"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.200" Y="2.538" X="6.087"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_104</Name>
<SubId ID="2104"></SubId>
<Group>
<Name>undest_room_104</Name>
<BBox_Min Z="-0.300" Y="-0.134" X="7.946"></BBox_Min>
<BBox_Max Z="2.690" Y="2.256" X="12.000"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="8.126"></BBox_Min>
<BBox_Max Z="0.000" Y="2.076" X="11.820"></BBox_Max>
<Polygon>
<Name>p6609</Name>
<Vertex>
<Name>p6609/V1</Name>
<Coord X="8.126" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6609/V2</Name>
<Coord X="11.820" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6609/V3</Name>
<Coord X="11.820" Y="2.076" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6609/V4</Name>
<Coord X="8.126" Y="2.076" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0008</Name>
<SubId ID="11008"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.268" Y="1.15" X="12.100999999999999"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0003</Name>
<SubId ID="11003"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.015" Y="-0.19" X="9.682"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_4</Name>
<SubId ID="16004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.072" X="9.990"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_3</Name>
<SubId ID="14003"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.200" Y="0.448" X="11.820"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=2.69</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.490" Y="-0.134" X="0.000"></BBox_Min>
<BBox_Max Z="6.538" Y="6.134" X="8.126"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.690" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="2.690" Y="5.820" X="7.946"></BBox_Max>
<Polygon>
<Name>p5562</Name>
<Vertex>
<Name>p5562/V1</Name>
<Coord X="7.946" Y="2.076" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p5562/V2</Name>
<Coord X="2.860" Y="2.076" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p5562/V3</Name>
<Coord X="2.860" Y="1.892" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p5562/V4</Name>
<Coord X="2.680" Y="1.892" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p5562/V5</Name>
<Coord X="2.680" Y="5.820" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p5562/V6</Name>
<Coord X="0.180" Y="5.820" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p5562/V7</Name>
<Coord X="0.180" Y="0.180" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p5562/V8</Name>
<Coord X="7.946" Y="0.180" Z="2.690"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0023</Name>
<SubId ID="11023"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.576" Y="6.122" X="1.439"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0005</Name>
<SubId ID="11005"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.454" Y="-0.123" X="6.565"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0004</Name>
<SubId ID="11004"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.495" Y="-0.117" X="3.823"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0015</Name>
<SubId ID="11015"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.485" Y="1.302" X="-0.132"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0014</Name>
<SubId ID="11014"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.466" Y="4.035" X="-0.13"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_5</Name>
<SubId ID="16005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.064" Y="1.135" X="2.148"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_4</Name>
<SubId ID="14004"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="3.000" Y="5.820" X="0.732"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_202</Name>
<SubId ID="2202"></SubId>
<Group>
<Name>undest_room_202</Name>
<BBox_Min Z="2.490" Y="2.076" X="2.680"></BBox_Min>
<BBox_Max Z="5.400" Y="6.000" X="6.087"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.690" Y="2.256" X="2.860"></BBox_Min>
<BBox_Max Z="2.690" Y="5.820" X="5.907"></BBox_Max>
<Polygon>
<Name>p5563</Name>
<Vertex>
<Name>p5563/V1</Name>
<Coord X="2.860" Y="2.256" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p5563/V2</Name>
<Coord X="5.907" Y="2.256" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p5563/V3</Name>
<Coord X="5.907" Y="5.820" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p5563/V4</Name>
<Coord X="2.860" Y="5.820" Z="2.690"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0022</Name>
<SubId ID="11022"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.564" Y="6.118" X="4.461"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_6</Name>
<SubId ID="16006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.064" Y="3.975" X="4.414"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_5</Name>
<SubId ID="14005"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.900" Y="5.820" X="3.367"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_203</Name>
<SubId ID="2203"></SubId>
<Group>
<Name>undest_room_203</Name>
<BBox_Min Z="2.490" Y="2.076" X="5.907"></BBox_Min>
<BBox_Max Z="5.400" Y="6.134" X="12.000"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.690" Y="2.256" X="6.087"></BBox_Min>
<BBox_Max Z="2.690" Y="5.820" X="11.820"></BBox_Max>
<Polygon>
<Name>p5564</Name>
<Vertex>
<Name>p5564/V1</Name>
<Coord X="11.820" Y="5.820" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p5564/V2</Name>
<Coord X="6.087" Y="5.820" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p5564/V3</Name>
<Coord X="6.087" Y="2.256" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p5564/V4</Name>
<Coord X="11.820" Y="2.256" Z="2.690"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0021</Name>
<SubId ID="11021"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.552" Y="6.118" X="8.615"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0011</Name>
<SubId ID="11011"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.526" Y="3.895" X="12.088"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_7</Name>
<SubId ID="16007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.064" Y="3.869" X="8.724"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_9</Name>
<SubId ID="14009"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="5.200" Y="5.066" X="11.820"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_204</Name>
<SubId ID="2204"></SubId>
<Group>
<Name>undest_room_204</Name>
<BBox_Min Z="2.490" Y="-0.134" X="7.946"></BBox_Min>
<BBox_Max Z="5.400" Y="2.256" X="12.000"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.690" Y="0.180" X="8.126"></BBox_Min>
<BBox_Max Z="2.690" Y="2.076" X="11.820"></BBox_Max>
<Polygon>
<Name>p5565</Name>
<Vertex>
<Name>p5565/V1</Name>
<Coord X="8.126" Y="0.180" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p5565/V2</Name>
<Coord X="11.820" Y="0.180" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p5565/V3</Name>
<Coord X="11.820" Y="2.076" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p5565/V4</Name>
<Coord X="8.126" Y="2.076" Z="2.690"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0010</Name>
<SubId ID="11010"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.454" Y="1.163" X="12.094"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0006</Name>
<SubId ID="11006"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.48" Y="-0.117" X="9.977"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_8</Name>
<SubId ID="16008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.064" Y="1.072" X="9.938"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_6</Name>
<SubId ID="14006"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="5.200" Y="0.974" X="11.820"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_3</Name>
<Comment>base_height=5.4</Comment>
<Switch>
<Name>SW_room_301</Name>
<SubId ID="2301"></SubId>
<Group>
<Name>undest_room_301</Name>
<BBox_Min Z="5.200" Y="-0.713" X="-0.200"></BBox_Min>
<BBox_Max Z="8.630" Y="6.713" X="12.220"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="5.400" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="5.400" Y="5.820" X="11.820"></BBox_Max>
<Polygon>
<Name>p4309</Name>
<Vertex>
<Name>p4309/V1</Name>
<Coord X="0.180" Y="0.180" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p4309/V2</Name>
<Coord X="11.820" Y="0.180" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p4309/V3</Name>
<Coord X="11.820" Y="5.820" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p4309/V4</Name>
<Coord X="0.180" Y="5.820" Z="5.400"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0024</Name>
<SubId ID="11024"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="7.90226" Y="5.558" X="8.943"></Coord>
<Dir Z="0.866" Y="0.500" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0007</Name>
<SubId ID="11007"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="7.876259999999999" Y="0.445" X="7.59"></Coord>
<Dir Z="0.866" Y="-0.500" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_9</Name>
<SubId ID="16009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="5.774" Y="2.926" X="6.192"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_7</Name>
<SubId ID="14007"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="7.500" Y="3.000" X="11.820"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_8</Name>
<SubId ID="14008"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="6.000" Y="5.820" X="0.739"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_4</Name>
<Comment>base_height=8.63</Comment>
<Switch>
<Name>SW_room_401</Name>
<SubId ID="2401"></SubId>
<Group>
<Name>undest_room_401</Name>
<BBox_Min Z="6.397" Y="-0.713" X="-0.200"></BBox_Min>
<BBox_Max Z="8.630" Y="6.713" X="12.220"></BBox_Max>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="2.240" Y="-0.100" X="0.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="7.052" X="1.477"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="7.052" X="5.977"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="7.052" X="10.477"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="4.500" X="13.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_5</Name>
<SubId ID="15005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="1.500" X="13.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_6</Name>
<SubId ID="15006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.070" X="10.500"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_7</Name>
<SubId ID="15007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.070" X="6.000"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_8</Name>
<SubId ID="15008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.070" X="1.500"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_9</Name>
<SubId ID="15009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="1.500" X="-1.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_10</Name>
<SubId ID="15010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="4.500" X="-1.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.618" Y="2.468" X="5.453"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>