Files
2026-10-23 16:13:31 +00:00

526 lines
27 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Tue Dec 14 11:38:53 2021 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_3255</Name>
<ModelId Id="1255"></ModelId>
<BBox_Min Z="-0.300" Y="-1.070" X="-1.070"></BBox_Min>
<BBox_Max Z="6.011" Y="13.070" X="7.070"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.000" X="0.000"></BBox_Min>
<BBox_Max Z="0.000" Y="12.000" X="6.000"></BBox_Max>
<Polygon>
<Name>p2164</Name>
<Vertex>
<Name>p2164/V1</Name>
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2164/V2</Name>
<Coord X="6.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2164/V3</Name>
<Coord X="6.000" Y="12.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2164/V4</Name>
<Coord X="0.000" Y="12.000" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0.00</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.300" Y="0.000" X="-0.151"></BBox_Min>
<BBox_Max Z="3.822" Y="12.000" X="6.156"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="0.000" Y="11.820" X="5.820"></BBox_Max>
<Polygon>
<Name>p2582</Name>
<Vertex>
<Name>p2582/V1</Name>
<Coord X="0.180" Y="2.666" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2582/V2</Name>
<Coord X="0.180" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2582/V3</Name>
<Coord X="5.820" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2582/V4</Name>
<Coord X="5.820" Y="11.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2582/V5</Name>
<Coord X="3.213" Y="11.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2582/V6</Name>
<Coord X="3.213" Y="9.178" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2582/V7</Name>
<Coord X="3.854" Y="9.178" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2582/V8</Name>
<Coord X="3.854" Y="2.846" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2582/V9</Name>
<Coord X="4.110" Y="2.846" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2582/V10</Name>
<Coord X="4.110" Y="2.666" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0012</Name>
<SubId ID="11012"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.252" Y="12.110999999999999" X="4.144"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0006</Name>
<SubId ID="11006"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.358" Y="1.416" X="-0.114"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0010</Name>
<SubId ID="11010"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.113" Y="8.808" X="6.19"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0008</Name>
<SubId ID="11008"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.103" Y="1.83" X="6.184"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0009</Name>
<SubId ID="11009"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.305" Y="6.418" X="6.121"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.397" Y="-0.122" X="4.282"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="1.560" Y="1.423" X="0.755"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.423" X="4.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_3</Name>
<SubId ID="16003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="5.922" X="4.837"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_4</Name>
<SubId ID="16004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="10.499" X="4.516"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_6</Name>
<SubId ID="14006"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.200" Y="11.820" X="5.491"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_102</Name>
<SubId ID="2102"></SubId>
<Group>
<Name>undest_room_102</Name>
<BBox_Min Z="-0.300" Y="2.462" X="-0.075"></BBox_Min>
<BBox_Max Z="2.700" Y="6.033" X="3.854"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="2.846" X="0.180"></BBox_Min>
<BBox_Max Z="0.000" Y="5.853" X="3.674"></BBox_Max>
<Polygon>
<Name>p2583</Name>
<Vertex>
<Name>p2583/V1</Name>
<Coord X="3.674" Y="5.853" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2583/V2</Name>
<Coord X="0.180" Y="5.853" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2583/V3</Name>
<Coord X="0.180" Y="2.846" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2583/V4</Name>
<Coord X="3.674" Y="2.846" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0005</Name>
<SubId ID="11005"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.091" Y="5.039" X="-0.192"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_5</Name>
<SubId ID="16005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.350" X="1.927"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.200" Y="5.374" X="0.180"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_103</Name>
<SubId ID="2103"></SubId>
<Group>
<Name>undest_room_103</Name>
<BBox_Min Z="-0.300" Y="5.853" X="-0.075"></BBox_Min>
<BBox_Max Z="2.700" Y="9.178" X="3.854"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="6.033" X="0.180"></BBox_Min>
<BBox_Max Z="0.000" Y="8.998" X="3.674"></BBox_Max>
<Polygon>
<Name>p2584</Name>
<Vertex>
<Name>p2584/V1</Name>
<Coord X="3.674" Y="8.998" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2584/V2</Name>
<Coord X="0.180" Y="8.998" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2584/V3</Name>
<Coord X="0.180" Y="6.033" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2584/V4</Name>
<Coord X="3.674" Y="6.033" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0004</Name>
<SubId ID="11004"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.098" Y="8.212" X="-0.185"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_6</Name>
<SubId ID="16006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.515" X="1.927"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_2</Name>
<SubId ID="14002"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.200" Y="6.646" X="0.180"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_104</Name>
<SubId ID="2104"></SubId>
<Group>
<Name>undest_room_104</Name>
<BBox_Min Z="-0.300" Y="8.998" X="-0.151"></BBox_Min>
<BBox_Max Z="2.700" Y="12.075" X="3.213"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="9.178" X="0.180"></BBox_Min>
<BBox_Max Z="0.000" Y="11.820" X="3.033"></BBox_Max>
<Polygon>
<Name>p2585</Name>
<Vertex>
<Name>p2585/V1</Name>
<Coord X="0.180" Y="9.178" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2585/V2</Name>
<Coord X="3.033" Y="9.178" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2585/V3</Name>
<Coord X="3.033" Y="11.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2585/V4</Name>
<Coord X="0.180" Y="11.820" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0013</Name>
<SubId ID="11013"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.105" Y="12.190999999999999" X="2.644"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0003</Name>
<SubId ID="11003"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.988" Y="10.071" X="-0.133"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_7</Name>
<SubId ID="16007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="10.499" X="1.606"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_5</Name>
<SubId ID="14005"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.200" Y="11.190" X="0.180"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=2.7</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.500" Y="-0.225" X="-0.737"></BBox_Min>
<BBox_Max Z="6.011" Y="12.225" X="6.741"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="2.700" Y="11.820" X="5.820"></BBox_Max>
<Polygon>
<Name>p2581</Name>
<Vertex>
<Name>p2581/V1</Name>
<Coord X="5.820" Y="11.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p2581/V2</Name>
<Coord X="0.180" Y="11.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p2581/V3</Name>
<Coord X="0.180" Y="0.180" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p2581/V4</Name>
<Coord X="5.820" Y="0.180" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0014</Name>
<SubId ID="11014"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.572" Y="12.112" X="2.945"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0007</Name>
<SubId ID="11007"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="5.3262599999999996" Y="8.711" X="0.466"></Coord>
<Dir Z="0.866" Y="-0.000" X="-0.500"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0011</Name>
<SubId ID="11011"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="5.29526" Y="5.974" X="5.585999999999999"></Coord>
<Dir Z="0.866" Y="-0.000" X="0.500"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.619" Y="-0.106" X="2.978"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_8</Name>
<SubId ID="16008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.000" Y="6.000" X="3.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_3</Name>
<SubId ID="14003"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="5.200" Y="11.820" X="3.002"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_4</Name>
<SubId ID="14004"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="3.500" Y="0.945" X="0.180"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_3</Name>
<Comment>base_height=6.01</Comment>
<Switch>
<Name>SW_room_301</Name>
<SubId ID="2301"></SubId>
<Group>
<Name>undest_room_301</Name>
<BBox_Min Z="3.755" Y="-0.225" X="-0.737"></BBox_Min>
<BBox_Max Z="6.011" Y="12.225" X="6.741"></BBox_Max>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="2.250" Y="-0.100" X="0.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="1.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="4.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="2.500" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="9.500" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_5</Name>
<SubId ID="15005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="6.000" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_6</Name>
<SubId ID="15006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="13.000" X="1.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_7</Name>
<SubId ID="15007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="13.000" X="4.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_8</Name>
<SubId ID="15008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="2.500" X="7.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_9</Name>
<SubId ID="15009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="9.500" X="7.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_10</Name>
<SubId ID="15010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="6.000" X="7.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.550" Y="6.407" X="3.574"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>