Files
2026-10-23 16:13:31 +00:00

768 lines
40 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Thu Dec 09 12:00:58 2021 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_3263</Name>
<ModelId Id="1263"></ModelId>
<BBox_Min Z="-0.300" Y="-1.070" X="-1.070"></BBox_Min>
<BBox_Max Z="8.630" Y="7.070" X="13.110"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.000" X="0.000"></BBox_Min>
<BBox_Max Z="0.000" Y="6.000" X="12.040"></BBox_Max>
<Polygon>
<Name>p3418</Name>
<Vertex>
<Name>p3418/V1</Name>
<Coord X="12.040" Y="6.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3418/V2</Name>
<Coord X="0.000" Y="6.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3418/V3</Name>
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3418/V4</Name>
<Coord X="12.040" Y="0.000" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0.00</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.300" Y="-0.140" X="0.000"></BBox_Min>
<BBox_Max Z="2.700" Y="3.111" X="6.859"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="0.000" Y="2.931" X="6.476"></BBox_Max>
<Polygon>
<Name>p3425</Name>
<Vertex>
<Name>p3425/V1</Name>
<Coord X="6.476" Y="2.931" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3425/V2</Name>
<Coord X="0.180" Y="2.931" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3425/V3</Name>
<Coord X="0.180" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3425/V4</Name>
<Coord X="6.476" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.868" Y="1.436" X="-0.084"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0006</Name>
<SubId ID="11006"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.291" Y="-0.12" X="5.087"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0005</Name>
<SubId ID="11005"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.046" Y="-0.185" X="2.347"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.556" X="3.328"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.300" Y="2.694" X="6.476"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_102</Name>
<SubId ID="2102"></SubId>
<Group>
<Name>undest_room_102</Name>
<BBox_Min Z="-0.300" Y="2.931" X="0.000"></BBox_Min>
<BBox_Max Z="2.700" Y="6.128" X="6.656"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="3.111" X="0.180"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="6.476"></BBox_Max>
<Polygon>
<Name>p3426</Name>
<Vertex>
<Name>p3426/V1</Name>
<Coord X="0.180" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3426/V2</Name>
<Coord X="0.180" Y="3.111" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3426/V3</Name>
<Coord X="6.476" Y="3.111" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3426/V4</Name>
<Coord X="6.476" Y="5.820" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0017</Name>
<SubId ID="11017"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.055" Y="6.205" X="3.171"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.195" Y="4.364" X="-0.07"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.466" X="3.328"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_2</Name>
<SubId ID="14002"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.300" Y="4.078" X="0.180"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_103</Name>
<SubId ID="2103"></SubId>
<Group>
<Name>undest_room_103</Name>
<BBox_Min Z="-0.300" Y="0.000" X="6.476"></BBox_Min>
<BBox_Max Z="3.816" Y="6.000" X="9.347"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="6.656"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="9.167"></BBox_Max>
<Polygon>
<Name>p3427</Name>
<Vertex>
<Name>p3427/V1</Name>
<Coord X="6.656" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3427/V2</Name>
<Coord X="6.656" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3427/V3</Name>
<Coord X="9.167" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3427/V4</Name>
<Coord X="9.167" Y="5.820" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0016</Name>
<SubId ID="11016"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.192" Y="6.11" X="7.889"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_3</Name>
<SubId ID="16003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="1.550" Y="0.810" X="7.911"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_4</Name>
<SubId ID="16004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.500" X="7.911"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_104</Name>
<SubId ID="2104"></SubId>
<Group>
<Name>undest_room_104</Name>
<BBox_Min Z="-0.300" Y="-0.140" X="8.964"></BBox_Min>
<BBox_Max Z="2.700" Y="6.128" X="12.040"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="9.347"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="11.840"></BBox_Max>
<Polygon>
<Name>p3428</Name>
<Vertex>
<Name>p3428/V1</Name>
<Coord X="9.347" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3428/V2</Name>
<Coord X="9.347" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3428/V3</Name>
<Coord X="11.840" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3428/V4</Name>
<Coord X="11.840" Y="5.820" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0013</Name>
<SubId ID="11013"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.19" Y="5.087" X="12.177"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0015</Name>
<SubId ID="11015"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.041" Y="6.17" X="11.356"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0010</Name>
<SubId ID="11010"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.184" Y="-0.14100000000000001" X="10.088"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_5</Name>
<SubId ID="16005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.000" X="10.593"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_3</Name>
<SubId ID="14003"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.300" Y="0.180" X="11.466"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=2.7</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.500" Y="-0.140" X="0.000"></BBox_Min>
<BBox_Max Z="5.410" Y="3.111" X="6.859"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="2.700" Y="2.931" X="6.476"></BBox_Max>
<Polygon>
<Name>p3438</Name>
<Vertex>
<Name>p3438/V1</Name>
<Coord X="6.476" Y="2.931" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p3438/V2</Name>
<Coord X="0.180" Y="2.931" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p3438/V3</Name>
<Coord X="0.180" Y="0.180" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p3438/V4</Name>
<Coord X="6.476" Y="0.180" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0004</Name>
<SubId ID="11004"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.89" Y="1.659" X="-0.08"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0008</Name>
<SubId ID="11008"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.505" Y="-0.115" X="3.803"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_6</Name>
<SubId ID="16006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.000" Y="1.556" X="3.328"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_4</Name>
<SubId ID="14004"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.900" Y="0.510" X="0.180"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_202</Name>
<SubId ID="2202"></SubId>
<Group>
<Name>undest_room_202</Name>
<BBox_Min Z="2.500" Y="2.931" X="0.000"></BBox_Min>
<BBox_Max Z="5.410" Y="6.128" X="6.656"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="3.111" X="0.180"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="6.476"></BBox_Max>
<Polygon>
<Name>p3439</Name>
<Vertex>
<Name>p3439/V1</Name>
<Coord X="6.476" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p3439/V2</Name>
<Coord X="0.180" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p3439/V3</Name>
<Coord X="0.180" Y="3.111" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p3439/V4</Name>
<Coord X="6.476" Y="3.111" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0020</Name>
<SubId ID="11020"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.499" Y="6.131" X="2.352"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0003</Name>
<SubId ID="11003"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.916" Y="4.412" X="-0.07100000000000001"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_7</Name>
<SubId ID="16007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.000" Y="4.466" X="3.328"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_5</Name>
<SubId ID="14005"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.900" Y="5.385" X="0.180"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_203</Name>
<SubId ID="2203"></SubId>
<Group>
<Name>undest_room_203</Name>
<BBox_Min Z="2.500" Y="0.000" X="6.476"></BBox_Min>
<BBox_Max Z="6.516" Y="6.000" X="9.347"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="0.180" X="6.656"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="9.167"></BBox_Max>
<Polygon>
<Name>p3434</Name>
<Vertex>
<Name>p3434/V1</Name>
<Coord X="9.167" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p3434/V2</Name>
<Coord X="6.656" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p3434/V3</Name>
<Coord X="6.656" Y="0.180" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p3434/V4</Name>
<Coord X="9.167" Y="0.180" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>subroom_1</Name>
<BBox_Min Z="2.700" Y="3.707" X="6.656"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="9.167"></BBox_Max>
</Group>
<Group>
<Name>subroom_2</Name>
<BBox_Min Z="2.700" Y="3.317" X="6.656"></BBox_Min>
<BBox_Max Z="2.700" Y="3.707" X="7.811"></BBox_Max>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0019</Name>
<SubId ID="11019"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.915" Y="6.109" X="7.861"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0009</Name>
<SubId ID="11009"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.447" Y="-0.136" X="8.439"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_8</Name>
<SubId ID="16008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="4.250" Y="0.750" X="7.911"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_9</Name>
<SubId ID="16009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.000" Y="4.764" X="7.911"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_9</Name>
<SubId ID="14009"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="3.500" Y="0.180" X="7.587"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_204</Name>
<SubId ID="2204"></SubId>
<Group>
<Name>undest_room_204</Name>
<BBox_Min Z="2.500" Y="-0.140" X="8.964"></BBox_Min>
<BBox_Max Z="5.410" Y="6.128" X="12.040"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="0.180" X="9.347"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="11.840"></BBox_Max>
<Polygon>
<Name>p3440</Name>
<Vertex>
<Name>p3440/V1</Name>
<Coord X="11.840" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p3440/V2</Name>
<Coord X="9.347" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p3440/V3</Name>
<Coord X="9.347" Y="0.180" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p3440/V4</Name>
<Coord X="11.840" Y="0.180" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0014</Name>
<SubId ID="11014"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.894" Y="5.082" X="12.179"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0018</Name>
<SubId ID="11018"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.495" Y="6.098000000000001" X="10.551"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0007</Name>
<SubId ID="11007"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.888" Y="-0.14100000000000001" X="10.096"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_10</Name>
<SubId ID="16010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.000" Y="3.000" X="10.593"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_6</Name>
<SubId ID="14006"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.900" Y="0.180" X="11.465"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_3</Name>
<Comment>base_height=6.0</Comment>
<Switch>
<Name>SW_room_301</Name>
<SubId ID="2301"></SubId>
<Group>
<Name>undest_room_301</Name>
<BBox_Min Z="5.210" Y="-0.719" X="-0.200"></BBox_Min>
<BBox_Max Z="8.630" Y="6.706" X="12.220"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="5.410" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="5.410" Y="5.820" X="11.840"></BBox_Max>
<Polygon>
<Name>p3450</Name>
<Vertex>
<Name>p3450/V1</Name>
<Coord X="0.180" Y="0.180" Z="5.410"></Coord>
</Vertex>
<Vertex>
<Name>p3450/V2</Name>
<Coord X="11.840" Y="0.180" Z="5.410"></Coord>
</Vertex>
<Vertex>
<Name>p3450/V3</Name>
<Coord X="11.840" Y="5.820" Z="5.410"></Coord>
</Vertex>
<Vertex>
<Name>p3450/V4</Name>
<Coord X="0.180" Y="5.820" Z="5.410"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>subroom_3</Name>
<BBox_Min Z="5.410" Y="0.180" X="9.167"></BBox_Min>
<BBox_Max Z="5.410" Y="5.820" X="11.840"></BBox_Max>
</Group>
<Group>
<Name>subroom_4</Name>
<BBox_Min Z="5.410" Y="3.707" X="6.656"></BBox_Min>
<BBox_Max Z="5.410" Y="5.820" X="9.167"></BBox_Max>
</Group>
<Group>
<Name>subroom_5</Name>
<BBox_Min Z="5.410" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="5.410" Y="5.820" X="6.656"></BBox_Max>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0021</Name>
<SubId ID="11021"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="7.807259999999999" Y="5.585" X="9.021"></Coord>
<Dir Z="0.866" Y="0.500" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0012</Name>
<SubId ID="11012"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="6.134" Y="-0.132" X="8.379"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0011</Name>
<SubId ID="11011"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="7.79026" Y="0.41300000000000003" X="3.063"></Coord>
<Dir Z="0.866" Y="-0.500" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_11</Name>
<SubId ID="16011"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="5.710" Y="3.000" X="10.503"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_12</Name>
<SubId ID="16012"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="5.710" Y="3.000" X="3.418"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_8</Name>
<SubId ID="14008"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="7.800" Y="2.994" X="0.180"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_7</Name>
<SubId ID="14007"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="6.000" Y="0.180" X="7.299"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_4</Name>
<Comment>base_height=8.63</Comment>
<Switch>
<Name>SW_room_401</Name>
<SubId ID="2401"></SubId>
<Group>
<Name>undest_room_401</Name>
<BBox_Min Z="6.397" Y="-0.719" X="-0.200"></BBox_Min>
<BBox_Max Z="8.630" Y="6.706" X="12.220"></BBox_Max>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="2.250" Y="0.100" X="-0.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="2.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="6.020"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="9.540"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.500" X="13.040"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_5</Name>
<SubId ID="15005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.500" X="13.040"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_6</Name>
<SubId ID="15006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.000" X="9.540"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_7</Name>
<SubId ID="15007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.000" X="6.020"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_8</Name>
<SubId ID="15008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.000" X="2.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_9</Name>
<SubId ID="15009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.500" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_10</Name>
<SubId ID="15010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.500" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.550" Y="5.720" X="7.965"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_2</Name>
<SubId ID="27002"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="3.250" Y="5.720" X="7.967"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>