Files
2026-10-23 16:13:31 +00:00

439 lines
22 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Tue Dec 14 15:30:53 2021 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_3265</Name>
<ModelId Id="1265"></ModelId>
<BBox_Min Z="-0.300" Y="-7.070" X="-13.070"></BBox_Min>
<BBox_Max Z="3.966" Y="1.070" X="1.070"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="-6.000" X="-12.000"></BBox_Min>
<BBox_Max Z="0.000" Y="0.000" X="0.000"></BBox_Max>
<Polygon>
<Name>p1658</Name>
<Vertex>
<Name>p1658/V1</Name>
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1658/V2</Name>
<Coord X="-12.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1658/V3</Name>
<Coord X="-12.000" Y="-6.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1658/V4</Name>
<Coord X="-0.000" Y="-6.000" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0.00</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.300" Y="-6.000" X="-5.156"></BBox_Min>
<BBox_Max Z="3.249" Y="0.340" X="0.072"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="-5.820" X="-4.976"></BBox_Min>
<BBox_Max Z="0.000" Y="-0.180" X="-0.180"></BBox_Max>
<Polygon>
<Name>p1693</Name>
<Vertex>
<Name>p1693/V1</Name>
<Coord X="-0.180" Y="-5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1693/V2</Name>
<Coord X="-0.180" Y="-0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1693/V3</Name>
<Coord X="-4.976" Y="-0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1693/V4</Name>
<Coord X="-4.976" Y="-5.820" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0003</Name>
<SubId ID="11003"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.257" Y="-6.090000000000001" X="-2.175"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.01" Y="-3.823" X="0.193"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0004</Name>
<SubId ID="11004"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.015" Y="0.213" X="-1.725"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-3.000" X="-2.578"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.300" Y="-5.820" X="-0.585"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_102</Name>
<SubId ID="2102"></SubId>
<Group>
<Name>undest_room_102</Name>
<BBox_Min Z="-0.300" Y="-6.072" X="-12.000"></BBox_Min>
<BBox_Max Z="2.872" Y="-3.763" X="-4.976"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="-5.820" X="-11.820"></BBox_Min>
<BBox_Max Z="0.000" Y="-3.943" X="-5.156"></BBox_Max>
<Polygon>
<Name>p1694</Name>
<Vertex>
<Name>p1694/V1</Name>
<Coord X="-5.156" Y="-5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1694/V2</Name>
<Coord X="-5.156" Y="-3.943" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1694/V3</Name>
<Coord X="-11.820" Y="-3.943" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1694/V4</Name>
<Coord X="-11.820" Y="-5.820" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.017" Y="-6.163" X="-9.316"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0009</Name>
<SubId ID="11009"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.275" Y="-4.804" X="-12.123999999999999"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-4.881" X="-8.488"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_2</Name>
<SubId ID="14002"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.300" Y="-5.820" X="-6.987"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_103</Name>
<SubId ID="2103"></SubId>
<Group>
<Name>undest_room_103</Name>
<BBox_Min Z="-0.300" Y="-3.943" X="-12.000"></BBox_Min>
<BBox_Max Z="2.804" Y="0.201" X="-4.976"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="-3.763" X="-11.820"></BBox_Min>
<BBox_Max Z="0.000" Y="-0.180" X="-5.156"></BBox_Max>
<Polygon>
<Name>p1695</Name>
<Vertex>
<Name>p1695/V1</Name>
<Coord X="-11.820" Y="-3.763" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1695/V2</Name>
<Coord X="-5.156" Y="-3.763" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1695/V3</Name>
<Coord X="-5.156" Y="-0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1695/V4</Name>
<Coord X="-7.133" Y="-0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1695/V5</Name>
<Coord X="-7.133" Y="-2.165" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1695/V6</Name>
<Coord X="-11.820" Y="-2.165" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0005</Name>
<SubId ID="11005"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.324" Y="0.139" X="-6.391"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0008</Name>
<SubId ID="11008"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.251" Y="-2.917" X="-12.128"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_3</Name>
<SubId ID="16003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.971" X="-6.144"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_4</Name>
<SubId ID="16004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-2.964" X="-9.477"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_3</Name>
<SubId ID="14003"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.300" Y="-3.763" X="-6.985"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_104</Name>
<SubId ID="2104"></SubId>
<Group>
<Name>undest_room_104</Name>
<BBox_Min Z="-0.300" Y="-2.287" X="-12.072"></BBox_Min>
<BBox_Max Z="2.750" Y="0.340" X="-7.133"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="-1.985" X="-11.820"></BBox_Min>
<BBox_Max Z="0.000" Y="-0.180" X="-7.313"></BBox_Max>
<Polygon>
<Name>p1696</Name>
<Vertex>
<Name>p1696/V1</Name>
<Coord X="-11.820" Y="-1.985" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1696/V2</Name>
<Coord X="-7.313" Y="-1.985" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1696/V3</Name>
<Coord X="-7.313" Y="-0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1696/V4</Name>
<Coord X="-11.820" Y="-0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0006</Name>
<SubId ID="11006"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.862" Y="0.147" X="-9.596"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0007</Name>
<SubId ID="11007"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.032" Y="-0.322" X="-12.200999999999999"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_5</Name>
<SubId ID="16005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.000" Y="-1.083" X="-9.567"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_4</Name>
<SubId ID="14004"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.300" Y="-0.452" X="-11.820"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=3.0</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.484" Y="-6.000" X="-12.000"></BBox_Min>
<BBox_Max Z="3.966" Y="0.370" X="0.000"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.690" Y="-5.820" X="-11.820"></BBox_Min>
<BBox_Max Z="2.690" Y="0.000" X="-0.180"></BBox_Max>
<Polygon>
<Name>p1706</Name>
<Vertex>
<Name>p1706/V1</Name>
<Coord X="-0.180" Y="-5.820" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p1706/V2</Name>
<Coord X="-0.180" Y="0.000" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p1706/V3</Name>
<Coord X="-11.820" Y="0.000" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p1706/V4</Name>
<Coord X="-11.820" Y="-5.820" Z="2.690"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>subroom_1</Name>
<BBox_Min Z="2.690" Y="-5.820" X="-11.820"></BBox_Min>
<BBox_Max Z="2.866" Y="0.000" X="-0.180"></BBox_Max>
</Group>
<External_Reference>
<Name>IPS_IN_AP_6</Name>
<SubId ID="16006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.050" Y="-2.910" X="-6.000"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="2.240" Y="-0.100" X="0.100"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-5.000" X="1.000"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="1.000"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.000" X="-2.500"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.000" X="-6.000"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_5</Name>
<SubId ID="15005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.000" X="-9.500"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_6</Name>
<SubId ID="15006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="-13.000"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_7</Name>
<SubId ID="15007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-5.000" X="-13.000"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_8</Name>
<SubId ID="15008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-7.000" X="-9.500"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_9</Name>
<SubId ID="15009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-7.000" X="-6.000"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_10</Name>
<SubId ID="15010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-7.000" X="-2.500"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.550" Y="-3.663" X="-5.538"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>