Files
2026-10-23 16:13:31 +00:00

536 lines
27 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Tue Jan 11 16:16:02 2022 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_4123</Name>
<ModelId Id="1123"></ModelId>
<BBox_Min Z="-0.300" Y="-1.073" X="-1.070"></BBox_Min>
<BBox_Max Z="5.938" Y="7.073" X="13.070"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.000" X="0.000"></BBox_Min>
<BBox_Max Z="0.000" Y="6.003" X="12.000"></BBox_Max>
<Polygon>
<Name>p2308</Name>
<Vertex>
<Name>p2308/V1</Name>
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2308/V2</Name>
<Coord X="12.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2308/V3</Name>
<Coord X="12.000" Y="6.003" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2308/V4</Name>
<Coord X="0.000" Y="6.003" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0.00</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.300" Y="-0.148" X="-0.074"></BBox_Min>
<BBox_Max Z="2.680" Y="2.229" X="3.354"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="0.000" Y="2.040" X="3.174"></BBox_Max>
<Polygon>
<Name>p2472</Name>
<Vertex>
<Name>p2472/V1</Name>
<Coord X="0.180" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2472/V2</Name>
<Coord X="3.174" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2472/V3</Name>
<Coord X="3.174" Y="2.040" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2472/V4</Name>
<Coord X="0.180" Y="2.040" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0006</Name>
<SubId ID="11006"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.125" Y="1.992" X="-0.20800000000000002"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.246" Y="-0.116012345678" X="1.68"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.110" X="1.677"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_6</Name>
<SubId ID="14006"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.292" Y="1.825" X="0.180"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_102</Name>
<SubId ID="2102"></SubId>
<Group>
<Name>undest_room_102</Name>
<BBox_Min Z="-0.300" Y="2.040" X="-0.074"></BBox_Min>
<BBox_Max Z="2.680" Y="6.159" X="5.628"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="2.220" X="0.180"></BBox_Min>
<BBox_Max Z="0.000" Y="5.823" X="5.448"></BBox_Max>
<Polygon>
<Name>p2474</Name>
<Vertex>
<Name>p2474/V1</Name>
<Coord X="0.180" Y="2.220" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2474/V2</Name>
<Coord X="5.448" Y="2.220" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2474/V3</Name>
<Coord X="5.448" Y="5.823" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2474/V4</Name>
<Coord X="0.180" Y="5.823" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0009</Name>
<SubId ID="11009"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.121" Y="6.224" X="5.029"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0010</Name>
<SubId ID="11010"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.934" Y="6.152" X="1.553"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0005</Name>
<SubId ID="11005"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.135" Y="5.304" X="-0.212"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.022" X="2.814"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.292" Y="2.220" X="1.119"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_103</Name>
<SubId ID="2103"></SubId>
<Group>
<Name>undest_room_103</Name>
<BBox_Min Z="-0.300" Y="1.891" X="5.448"></BBox_Min>
<BBox_Max Z="2.680" Y="6.078" X="9.510"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="2.220" X="5.628"></BBox_Min>
<BBox_Max Z="0.000" Y="5.823" X="9.126"></BBox_Max>
<Polygon>
<Name>p2475</Name>
<Vertex>
<Name>p2475/V1</Name>
<Coord X="5.628" Y="2.220" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2475/V2</Name>
<Coord X="9.126" Y="2.220" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2475/V3</Name>
<Coord X="9.126" Y="5.823" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2475/V4</Name>
<Coord X="5.628" Y="5.823" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0008</Name>
<SubId ID="11008"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.126" Y="6.227" X="7.998"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_3</Name>
<SubId ID="16003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.022" X="7.377"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_2</Name>
<SubId ID="14002"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.292" Y="2.220" X="7.212"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_104</Name>
<SubId ID="2104"></SubId>
<Group>
<Name>undest_room_104</Name>
<BBox_Min Z="-0.300" Y="1.891" X="9.126"></BBox_Min>
<BBox_Max Z="2.480" Y="6.003" X="10.326"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="2.244" X="9.306"></BBox_Min>
<BBox_Max Z="0.000" Y="5.823" X="10.146"></BBox_Max>
<Polygon>
<Name>p2476</Name>
<Vertex>
<Name>p2476/V1</Name>
<Coord X="9.306" Y="2.244" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2476/V2</Name>
<Coord X="10.146" Y="2.244" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2476/V3</Name>
<Coord X="10.146" Y="5.823" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2476/V4</Name>
<Coord X="9.306" Y="5.823" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>IPS_IN_AP_4</Name>
<SubId ID="16004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.000" X="9.726"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_105</Name>
<SubId ID="2105"></SubId>
<Group>
<Name>undest_room_105</Name>
<BBox_Min Z="-0.300" Y="-0.148" X="3.174"></BBox_Min>
<BBox_Max Z="3.811" Y="6.159" X="12.075"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="3.354"></BBox_Min>
<BBox_Max Z="0.000" Y="5.823" X="11.820"></BBox_Max>
<Polygon>
<Name>p2477</Name>
<Vertex>
<Name>p2477/V1</Name>
<Coord X="11.820" Y="5.823" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2477/V2</Name>
<Coord X="10.326" Y="5.823" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2477/V3</Name>
<Coord X="10.326" Y="2.064" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2477/V4</Name>
<Coord X="3.354" Y="2.040" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2477/V5</Name>
<Coord X="3.354" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2477/V6</Name>
<Coord X="11.820" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0003</Name>
<SubId ID="11003"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.376" Y="-0.12101234567800001" X="9.659"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.145" Y="-0.201" X="6.526"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0012</Name>
<SubId ID="11012"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.144" Y="0.536" X="12.155"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_5</Name>
<SubId ID="16005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.110" X="6.240"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_6</Name>
<SubId ID="16006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.110" X="10.473"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_7</Name>
<SubId ID="16007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="1.530" Y="5.245" X="10.562"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_3</Name>
<SubId ID="14003"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.292" Y="1.280" X="3.354"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=2.68</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.480" Y="-0.733" X="-0.225"></BBox_Min>
<BBox_Max Z="5.938" Y="6.745" X="12.225"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.680" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="2.680" Y="5.823" X="11.820"></BBox_Max>
<Polygon>
<Name>p2516</Name>
<Vertex>
<Name>p2516/V1</Name>
<Coord X="0.180" Y="0.180" Z="2.680"></Coord>
</Vertex>
<Vertex>
<Name>p2516/V2</Name>
<Coord X="11.820" Y="0.180" Z="2.680"></Coord>
</Vertex>
<Vertex>
<Name>p2516/V3</Name>
<Coord X="11.820" Y="5.823" Z="2.680"></Coord>
</Vertex>
<Vertex>
<Name>p2516/V4</Name>
<Coord X="0.180" Y="5.823" Z="2.680"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0011</Name>
<SubId ID="11011"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="5.46526" Y="5.2749999999999995" X="5.994"></Coord>
<Dir Z="0.866" Y="0.500" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0007</Name>
<SubId ID="11007"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.523" Y="3.01" X="-0.131"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0004</Name>
<SubId ID="11004"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="5.381259999999999" Y="0.755" X="7.97"></Coord>
<Dir Z="0.866" Y="-0.500" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0013</Name>
<SubId ID="11013"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.538" Y="3.058" X="12.127012345678"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_8</Name>
<SubId ID="16008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="2.980" Y="3.002" X="6.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_4</Name>
<SubId ID="14004"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="3.534" Y="5.823" X="9.993"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_5</Name>
<SubId ID="14005"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="5.167" Y="3.006" X="0.180"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_3</Name>
<Comment>base_height=5.94</Comment>
<Switch>
<Name>SW_room_301</Name>
<SubId ID="2301"></SubId>
<Group>
<Name>undest_room_301</Name>
<BBox_Min Z="3.683" Y="-0.733" X="-0.225"></BBox_Min>
<BBox_Max Z="5.938" Y="6.745" X="12.225"></BBox_Max>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="2.430" Y="5.903" X="12.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.503" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.500" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="2.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="6.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_5</Name>
<SubId ID="15005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.003" X="9.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_6</Name>
<SubId ID="15006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.500" X="13.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_7</Name>
<SubId ID="15007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.503" X="13.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_8</Name>
<SubId ID="15008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.003" X="9.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_9</Name>
<SubId ID="15009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.003" X="6.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_10</Name>
<SubId ID="15010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.003" X="2.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.540" Y="3.787" X="9.026"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>