Files
qt6-migration-pipeline/external/BuildingModels/StaticMeshes/bldg_1112.flt.xml
T
2026-10-23 16:13:31 +00:00

558 lines
29 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Tue Oct 26 13:25:41 2021 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_1112</Name>
<ModelId Id="1112"></ModelId>
<BBox_Min Z="-0.008" Y="-9.894" X="-1.070"></BBox_Min>
<BBox_Max Z="6.794" Y="1.070" X="13.091"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="-8.824" X="0.000"></BBox_Min>
<BBox_Max Z="0.000" Y="0.000" X="12.021"></BBox_Max>
<Polygon>
<Name>p5530</Name>
<Vertex>
<Name>p5530/V1</Name>
<Coord X="12.021" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5530/V2</Name>
<Coord X="12.021" Y="-8.824" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5530/V3</Name>
<Coord X="0.000" Y="-8.824" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5530/V4</Name>
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0.00</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.008" Y="-8.975" X="0.000"></BBox_Min>
<BBox_Max Z="3.983" Y="-2.868" X="6.230"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.200" Y="-8.644" X="0.180"></BBox_Min>
<BBox_Max Z="0.200" Y="-3.048" X="6.050"></BBox_Max>
<Polygon>
<Name>ce_in_1_f0_2</Name>
<Vertex>
<Name>ce_in_1_f0_2/V1</Name>
<Coord X="2.398" Y="-5.623" Z="0.200"></Coord>
</Vertex>
<Vertex>
<Name>ce_in_1_f0_2/V2</Name>
<Coord X="6.050" Y="-5.623" Z="0.200"></Coord>
</Vertex>
<Vertex>
<Name>ce_in_1_f0_2/V3</Name>
<Coord X="6.050" Y="-3.048" Z="0.200"></Coord>
</Vertex>
<Vertex>
<Name>ce_in_1_f0_2/V4</Name>
<Coord X="0.180" Y="-3.048" Z="0.200"></Coord>
</Vertex>
<Vertex>
<Name>ce_in_1_f0_2/V5</Name>
<Coord X="0.180" Y="-8.644" Z="0.200"></Coord>
</Vertex>
<Vertex>
<Name>ce_in_1_f0_2/V6</Name>
<Coord X="2.398" Y="-8.644" Z="0.200"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>subroom_2</Name>
<BBox_Min Z="1.430" Y="-4.072" X="2.783"></BBox_Min>
<BBox_Max Z="2.699" Y="-3.048" X="4.763"></BBox_Max>
</Group>
<Group>
<Name>subroom_3</Name>
<BBox_Min Z="1.430" Y="-5.623" X="4.762"></BBox_Min>
<BBox_Max Z="1.430" Y="-3.048" X="6.050"></BBox_Max>
</Group>
<Group>
<Name>subroom_4</Name>
<BBox_Min Z="0.200" Y="-5.623" X="2.873"></BBox_Min>
<BBox_Max Z="1.430" Y="-4.591" X="4.763"></BBox_Max>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.064" Y="-9.017999999999999" X="1.376"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0010</Name>
<SubId ID="11010"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.299" Y="-6.883" X="-0.109"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0009</Name>
<SubId ID="11009"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.854" Y="-4.427" X="-0.108"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.463" Y="-5.189" X="1.287"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="1.693" Y="-4.416" X="5.421"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.495" Y="-3.048" X="0.545"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_6</Name>
<SubId ID="14006"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.382" Y="-5.193" X="6.050"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_102</Name>
<SubId ID="2102"></SubId>
<Group>
<Name>undest_room_102</Name>
<BBox_Min Z="0.000" Y="-8.903" X="2.398"></BBox_Min>
<BBox_Max Z="2.880" Y="-5.603" X="6.230"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.200" Y="-8.644" X="2.578"></BBox_Min>
<BBox_Max Z="0.200" Y="-5.803" X="6.050"></BBox_Max>
<Polygon>
<Name>ce_in_2_f0_1</Name>
<Vertex>
<Name>ce_in_2_f0_1/V1</Name>
<Coord X="2.578" Y="-5.803" Z="0.200"></Coord>
</Vertex>
<Vertex>
<Name>ce_in_2_f0_1/V2</Name>
<Coord X="2.578" Y="-8.644" Z="0.200"></Coord>
</Vertex>
<Vertex>
<Name>ce_in_2_f0_1/V3</Name>
<Coord X="6.050" Y="-8.644" Z="0.200"></Coord>
</Vertex>
<Vertex>
<Name>ce_in_2_f0_1/V4</Name>
<Coord X="6.050" Y="-5.803" Z="0.200"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.07" Y="-9.014999999999999" X="4.503"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_3</Name>
<SubId ID="16003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.463" Y="-7.195" X="4.220"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_2</Name>
<SubId ID="14002"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.382" Y="-5.803" X="2.807"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_103</Name>
<SubId ID="2103"></SubId>
<Group>
<Name>undest_room_103</Name>
<BBox_Min Z="-0.008" Y="-8.975" X="6.050"></BBox_Min>
<BBox_Max Z="2.880" Y="-2.868" X="12.106"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.200" Y="-8.644" X="6.230"></BBox_Min>
<BBox_Max Z="0.200" Y="-3.048" X="11.841"></BBox_Max>
<Polygon>
<Name>ce_in_3_f0_1</Name>
<Vertex>
<Name>ce_in_3_f0_1/V1</Name>
<Coord X="6.230" Y="-3.048" Z="0.200"></Coord>
</Vertex>
<Vertex>
<Name>ce_in_3_f0_1/V2</Name>
<Coord X="6.230" Y="-8.644" Z="0.200"></Coord>
</Vertex>
<Vertex>
<Name>ce_in_3_f0_1/V3</Name>
<Coord X="11.841" Y="-8.644" Z="0.200"></Coord>
</Vertex>
<Vertex>
<Name>ce_in_3_f0_1/V4</Name>
<Coord X="11.841" Y="-3.048" Z="0.200"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0012</Name>
<SubId ID="11012"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.023" Y="-4.726" X="12.225"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0003</Name>
<SubId ID="11003"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.068" Y="-9.017" X="8.775"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_4</Name>
<SubId ID="16004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.463" Y="-5.724" X="8.813"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_3</Name>
<SubId ID="14003"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.382" Y="-3.048" X="11.217"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_104</Name>
<SubId ID="2104"></SubId>
<Group>
<Name>undest_room_104</Name>
<BBox_Min Z="-0.008" Y="-3.048" X="-0.071"></BBox_Min>
<BBox_Max Z="2.880" Y="0.159" X="12.021"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.200" Y="-2.868" X="0.180"></BBox_Min>
<BBox_Max Z="0.200" Y="-0.180" X="11.841"></BBox_Max>
<Polygon>
<Name>ce_in_4_f0_1</Name>
<Vertex>
<Name>ce_in_4_f0_1/V1</Name>
<Coord X="0.180" Y="-0.180" Z="0.200"></Coord>
</Vertex>
<Vertex>
<Name>ce_in_4_f0_1/V2</Name>
<Coord X="0.180" Y="-2.868" Z="0.200"></Coord>
</Vertex>
<Vertex>
<Name>ce_in_4_f0_1/V3</Name>
<Coord X="11.841" Y="-2.868" Z="0.200"></Coord>
</Vertex>
<Vertex>
<Name>ce_in_4_f0_1/V4</Name>
<Coord X="11.841" Y="-0.180" Z="0.200"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0006</Name>
<SubId ID="11006"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.024" Y="0.18" X="3.314"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0005</Name>
<SubId ID="11005"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.019" Y="0.176" X="9.309"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0013</Name>
<SubId ID="11013"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.262" Y="-1.57" X="12.155"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0008</Name>
<SubId ID="11008"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.013" Y="-1.342" X="-0.173"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_5</Name>
<SubId ID="16005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.500" Y="-1.524" X="8.926"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_7</Name>
<SubId ID="16007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.500" Y="-1.524" X="3.095"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_4</Name>
<SubId ID="14004"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.501" Y="-0.701" X="11.841"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=2.88</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.660" Y="-9.543" X="-0.202"></BBox_Min>
<BBox_Max Z="6.794" Y="0.727" X="12.237"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.880" Y="-8.644" X="2.200"></BBox_Min>
<BBox_Max Z="2.880" Y="-0.180" X="11.841"></BBox_Max>
<Polygon>
<Name>p5525</Name>
<Vertex>
<Name>p5525/V1</Name>
<Coord X="2.200" Y="-0.180" Z="2.880"></Coord>
</Vertex>
<Vertex>
<Name>p5525/V2</Name>
<Coord X="2.203" Y="-2.782" Z="2.880"></Coord>
</Vertex>
<Vertex>
<Name>p5525/V3</Name>
<Coord X="6.230" Y="-2.782" Z="2.880"></Coord>
</Vertex>
<Vertex>
<Name>p5525/V4</Name>
<Coord X="6.230" Y="-5.775" Z="2.880"></Coord>
</Vertex>
<Vertex>
<Name>p5525/V5</Name>
<Coord X="2.203" Y="-5.775" Z="2.880"></Coord>
</Vertex>
<Vertex>
<Name>p5525/V6</Name>
<Coord X="2.202" Y="-8.644" Z="2.880"></Coord>
</Vertex>
<Vertex>
<Name>p5525/V7</Name>
<Coord X="11.841" Y="-8.644" Z="2.880"></Coord>
</Vertex>
<Vertex>
<Name>p5525/V8</Name>
<Coord X="11.841" Y="-0.180" Z="2.880"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.880" Y="-8.644" X="0.180"></BBox_Min>
<BBox_Max Z="2.880" Y="-0.180" X="2.202"></BBox_Max>
<Polygon>
<Name>p5526</Name>
<Vertex>
<Name>p5526/V1</Name>
<Coord X="2.200" Y="-0.180" Z="2.880"></Coord>
</Vertex>
<Vertex>
<Name>p5526/V2</Name>
<Coord X="0.180" Y="-0.180" Z="2.880"></Coord>
</Vertex>
<Vertex>
<Name>p5526/V3</Name>
<Coord X="0.180" Y="-8.644" Z="2.880"></Coord>
</Vertex>
<Vertex>
<Name>p5526/V4</Name>
<Coord X="2.202" Y="-8.644" Z="2.880"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0007</Name>
<SubId ID="11007"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.89826" Y="-0.49800000000000005" X="8.338"></Coord>
<Dir Z="0.866" Y="0.500" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0014</Name>
<SubId ID="11014"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.455" Y="-4.465" X="12.154"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0004</Name>
<SubId ID="11004"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.72826" Y="-8.222" X="3.082"></Coord>
<Dir Z="0.866" Y="-0.500" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0011</Name>
<SubId ID="11011"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.431" Y="-4.396" X="-0.104"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_6</Name>
<SubId ID="16006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.143" Y="-4.248" X="7.458"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_5</Name>
<SubId ID="14005"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="5.098" Y="-4.354" X="0.180"></Coord>
<Dir Z="0.000" Y="0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_3</Name>
<Comment>base_height=6.79</Comment>
<Switch>
<Name>SW_room_301</Name>
<SubId ID="2301"></SubId>
<Group>
<Name>undest_room_301</Name>
<BBox_Min Z="2.660" Y="-9.543" X="-0.202"></BBox_Min>
<BBox_Max Z="6.794" Y="0.727" X="12.237"></BBox_Max>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="2.630" Y="-0.100" X="-0.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-6.324" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-2.500" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-9.824" X="9.521"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-9.824" X="6.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_5</Name>
<SubId ID="15005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-9.824" X="2.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_6</Name>
<SubId ID="15006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-6.324" X="13.021"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_7</Name>
<SubId ID="15007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-2.500" X="13.021"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_8</Name>
<SubId ID="15008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.000" X="6.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_9</Name>
<SubId ID="15009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.000" X="9.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_10</Name>
<SubId ID="15010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.000" X="2.479"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.600" Y="-3.148" X="0.515"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>