Files
qt6-migration-pipeline/external/BuildingModels/StaticMeshes/bldg_1143.flt.xml
T
2026-10-23 16:13:31 +00:00

187 lines
8.8 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Mon Nov 01 17:47:00 2021 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_1143</Name>
<ModelId Id="1143"></ModelId>
<BBox_Min Z="-0.200" Y="-1.140" X="-1.140"></BBox_Min>
<BBox_Max Z="3.994" Y="6.931" X="4.174"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="-0.000" X="0.000"></BBox_Min>
<BBox_Max Z="0.000" Y="5.796" X="3.007"></BBox_Max>
<Polygon>
<Name>p923</Name>
<Vertex>
<Name>p923/V1</Name>
<Coord X="3.007" Y="5.796" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p923/V2</Name>
<Coord X="0.000" Y="5.796" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p923/V3</Name>
<Coord X="0.000" Y="-0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p923/V4</Name>
<Coord X="3.007" Y="-0.000" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0.00</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.200" Y="-0.000" X="0.000"></BBox_Min>
<BBox_Max Z="2.869" Y="5.992" X="3.007"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="0.090"></BBox_Min>
<BBox_Max Z="0.000" Y="5.616" X="2.917"></BBox_Max>
<Polygon>
<Name>p922</Name>
<Vertex>
<Name>p922/V1</Name>
<Coord X="2.917" Y="5.616" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p922/V2</Name>
<Coord X="0.090" Y="5.616" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p922/V3</Name>
<Coord X="0.090" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p922/V4</Name>
<Coord X="2.917" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.941" Y="5.931" X="2.292"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.429" Y="-0.115" X="1.054"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.178" Y="0.180" X="2.568"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="2.920" X="1.574"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=2.7</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.499" Y="-0.000" X="-0.000"></BBox_Min>
<BBox_Max Z="3.994" Y="6.152" X="3.007"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.692" Y="0.180" X="0.000"></BBox_Min>
<BBox_Max Z="2.692" Y="5.992" X="3.007"></BBox_Max>
<Polygon>
<Name>p924</Name>
<Vertex>
<Name>p924/V1</Name>
<Coord X="0.000" Y="0.180" Z="2.692"></Coord>
</Vertex>
<Vertex>
<Name>p924/V2</Name>
<Coord X="3.007" Y="0.180" Z="2.692"></Coord>
</Vertex>
<Vertex>
<Name>p924/V3</Name>
<Coord X="3.007" Y="5.992" Z="2.692"></Coord>
</Vertex>
<Vertex>
<Name>p924/V4</Name>
<Coord X="0.000" Y="5.992" Z="2.692"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.067" Y="2.599" X="1.451"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="2.418" Y="-0.100" X="0.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="6.861" X="1.500"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="2.998" X="4.104"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.070" X="1.500"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="2.780" X="-1.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.600" Y="5.516" X="0.407"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>