1618 lines
86 KiB
XML
Executable File
1618 lines
86 KiB
XML
Executable File
<?xml version="1.0" ?>
|
|
<!--fltHdrLastDate Tue Nov 09 12:27:35 2021 - PostProcessed by SLTE $Rev: 56086 $-->
|
|
<STREIF>
|
|
<Header>
|
|
<Group>
|
|
<Name>bldg_1170</Name>
|
|
<ModelId Id="1170"></ModelId>
|
|
<BBox_Min Z="-2.910" Y="-12.979" X="-18.980"></BBox_Min>
|
|
<BBox_Max Z="6.639" Y="1.140" X="1.140"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="-11.839" X="-17.840"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="0.000" X="0.000"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p10009</Name>
|
|
<Vertex>
|
|
<Name>p10009/V1</Name>
|
|
<Coord X="-17.840" Y="-11.839" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p10009/V2</Name>
|
|
<Coord X="0.000" Y="-11.839" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p10009/V3</Name>
|
|
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p10009/V4</Name>
|
|
<Coord X="-17.840" Y="0.000" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<Group>
|
|
<Name>floor_-1</Name>
|
|
<Comment>base_height=-2.71</Comment>
|
|
<Switch>
|
|
<Name>SW_room_001</Name>
|
|
<SubId ID="2001"></SubId>
|
|
<Group>
|
|
<Name>undest_room_001</Name>
|
|
<BBox_Min Z="-2.910" Y="-11.839" X="-17.840"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="-7.110" X="-14.720"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="-2.710" Y="-11.659" X="-17.660"></BBox_Min>
|
|
<BBox_Max Z="-2.710" Y="-7.290" X="-14.900"></BBox_Max>
|
|
<Polygon>
|
|
<Name>ce_in_p_1</Name>
|
|
<Vertex>
|
|
<Name>ce_in_p_1/V1</Name>
|
|
<Coord X="-17.660" Y="-7.290" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_1/V2</Name>
|
|
<Coord X="-17.660" Y="-11.659" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_1/V3</Name>
|
|
<Coord X="-14.900" Y="-11.659" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_1/V4</Name>
|
|
<Coord X="-14.900" Y="-7.290" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_1/V5</Name>
|
|
<Coord X="-15.614" Y="-7.290" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_1/V6</Name>
|
|
<Coord X="-16.624" Y="-7.290" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_1</Name>
|
|
<SubId ID="16001"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="-2.447" Y="-9.470" X="-16.272"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_1</Name>
|
|
<SubId ID="14001"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="-0.349" Y="-11.659" X="-17.252"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_002</Name>
|
|
<SubId ID="2002"></SubId>
|
|
<Group>
|
|
<Name>undest_room_002</Name>
|
|
<BBox_Min Z="-2.910" Y="-11.839" X="-14.900"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="-7.110" X="-11.811"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="-2.710" Y="-11.659" X="-14.720"></BBox_Min>
|
|
<BBox_Max Z="-2.710" Y="-7.290" X="-11.991"></BBox_Max>
|
|
<Polygon>
|
|
<Name>ce_in_p_8</Name>
|
|
<Vertex>
|
|
<Name>ce_in_p_8/V1</Name>
|
|
<Coord X="-14.720" Y="-7.290" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_8/V2</Name>
|
|
<Coord X="-14.720" Y="-11.659" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_8/V3</Name>
|
|
<Coord X="-11.991" Y="-11.659" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_8/V4</Name>
|
|
<Coord X="-11.991" Y="-7.290" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_8/V5</Name>
|
|
<Coord X="-12.819" Y="-7.290" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_8/V6</Name>
|
|
<Coord X="-13.829" Y="-7.290" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_2</Name>
|
|
<SubId ID="16002"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="-2.447" Y="-9.554" X="-13.348"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_2</Name>
|
|
<SubId ID="14002"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="-0.349" Y="-11.659" X="-14.332"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_003</Name>
|
|
<SubId ID="2003"></SubId>
|
|
<Group>
|
|
<Name>undest_room_003</Name>
|
|
<BBox_Min Z="-2.910" Y="-7.290" X="-17.840"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="0.000" X="-11.811"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="-2.710" Y="-7.110" X="-17.660"></BBox_Min>
|
|
<BBox_Max Z="-2.710" Y="-0.180" X="-11.991"></BBox_Max>
|
|
<Polygon>
|
|
<Name>ce_in_p_15</Name>
|
|
<Vertex>
|
|
<Name>ce_in_p_15/V1</Name>
|
|
<Coord X="-17.660" Y="-0.180" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_15/V2</Name>
|
|
<Coord X="-17.660" Y="-7.110" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_15/V3</Name>
|
|
<Coord X="-16.624" Y="-7.110" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_15/V4</Name>
|
|
<Coord X="-15.614" Y="-7.110" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_15/V5</Name>
|
|
<Coord X="-13.829" Y="-7.110" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_15/V6</Name>
|
|
<Coord X="-12.819" Y="-7.110" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_15/V7</Name>
|
|
<Coord X="-11.991" Y="-7.110" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_15/V8</Name>
|
|
<Coord X="-11.991" Y="-6.451" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_15/V9</Name>
|
|
<Coord X="-11.991" Y="-5.441" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_15/V10</Name>
|
|
<Coord X="-11.991" Y="-1.727" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_15/V11</Name>
|
|
<Coord X="-11.991" Y="-0.717" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_15/V12</Name>
|
|
<Coord X="-11.991" Y="-0.180" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_3</Name>
|
|
<SubId ID="16003"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="-2.447" Y="-3.637" X="-14.832"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_3</Name>
|
|
<SubId ID="14003"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="-0.565" Y="-0.622" X="-17.660"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_004</Name>
|
|
<SubId ID="2004"></SubId>
|
|
<Group>
|
|
<Name>undest_room_004</Name>
|
|
<BBox_Min Z="-2.910" Y="-11.839" X="-11.991"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="-7.110" X="-5.789"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="-2.710" Y="-11.659" X="-11.811"></BBox_Min>
|
|
<BBox_Max Z="-2.710" Y="-7.290" X="-5.969"></BBox_Max>
|
|
<Polygon>
|
|
<Name>ce_in_p_22</Name>
|
|
<Vertex>
|
|
<Name>ce_in_p_22/V1</Name>
|
|
<Coord X="-11.811" Y="-7.290" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_22/V2</Name>
|
|
<Coord X="-11.811" Y="-11.659" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_22/V3</Name>
|
|
<Coord X="-5.969" Y="-11.659" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_22/V4</Name>
|
|
<Coord X="-5.969" Y="-7.290" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_22/V5</Name>
|
|
<Coord X="-7.019" Y="-7.290" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_22/V6</Name>
|
|
<Coord X="-8.029" Y="-7.290" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_4</Name>
|
|
<SubId ID="16004"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="-2.447" Y="-9.498" X="-9.047"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_4</Name>
|
|
<SubId ID="14004"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="-0.349" Y="-11.398" X="-11.811"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_005</Name>
|
|
<SubId ID="2005"></SubId>
|
|
<Group>
|
|
<Name>undest_room_005</Name>
|
|
<BBox_Min Z="-2.910" Y="-7.290" X="-11.991"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="-4.906" X="-5.789"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="-2.710" Y="-7.110" X="-11.811"></BBox_Min>
|
|
<BBox_Max Z="-2.710" Y="-5.086" X="-5.969"></BBox_Max>
|
|
<Polygon>
|
|
<Name>ce_in_p_29</Name>
|
|
<Vertex>
|
|
<Name>ce_in_p_29/V1</Name>
|
|
<Coord X="-11.811" Y="-5.086" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_29/V2</Name>
|
|
<Coord X="-11.811" Y="-5.441" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_29/V3</Name>
|
|
<Coord X="-11.811" Y="-6.451" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_29/V4</Name>
|
|
<Coord X="-11.811" Y="-7.110" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_29/V5</Name>
|
|
<Coord X="-8.029" Y="-7.110" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_29/V6</Name>
|
|
<Coord X="-7.019" Y="-7.110" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_29/V7</Name>
|
|
<Coord X="-5.969" Y="-7.110" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_29/V8</Name>
|
|
<Coord X="-5.969" Y="-6.460" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_29/V9</Name>
|
|
<Coord X="-5.969" Y="-5.450" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_29/V10</Name>
|
|
<Coord X="-5.969" Y="-5.086" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_29/V11</Name>
|
|
<Coord X="-6.897" Y="-5.086" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_29/V12</Name>
|
|
<Coord X="-7.907" Y="-5.086" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_5</Name>
|
|
<SubId ID="16005"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="-2.447" Y="-6.042" X="-8.987"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_5</Name>
|
|
<SubId ID="14005"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="-0.351" Y="-6.835" X="-11.811"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_006</Name>
|
|
<SubId ID="2006"></SubId>
|
|
<Group>
|
|
<Name>undest_room_006</Name>
|
|
<BBox_Min Z="-2.910" Y="-5.086" X="-11.991"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="0.000" X="-8.608"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="-2.710" Y="-4.906" X="-11.811"></BBox_Min>
|
|
<BBox_Max Z="-2.710" Y="-0.180" X="-8.788"></BBox_Max>
|
|
<Polygon>
|
|
<Name>ce_in_p_36</Name>
|
|
<Vertex>
|
|
<Name>ce_in_p_36/V1</Name>
|
|
<Coord X="-11.811" Y="-0.180" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_36/V2</Name>
|
|
<Coord X="-11.811" Y="-0.717" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_36/V3</Name>
|
|
<Coord X="-11.811" Y="-1.727" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_36/V4</Name>
|
|
<Coord X="-11.811" Y="-4.906" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_36/V5</Name>
|
|
<Coord X="-8.788" Y="-4.906" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_36/V6</Name>
|
|
<Coord X="-8.788" Y="-0.180" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_6</Name>
|
|
<SubId ID="16006"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="-2.447" Y="-2.711" X="-10.317"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_6</Name>
|
|
<SubId ID="14006"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="-0.349" Y="-0.934" X="-8.788"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_007</Name>
|
|
<SubId ID="2007"></SubId>
|
|
<Group>
|
|
<Name>undest_room_007</Name>
|
|
<BBox_Min Z="-2.910" Y="-5.086" X="-8.788"></BBox_Min>
|
|
<BBox_Max Z="1.121" Y="0.000" X="-5.789"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="-2.710" Y="-4.906" X="-8.608"></BBox_Min>
|
|
<BBox_Max Z="-2.710" Y="-0.180" X="-5.969"></BBox_Max>
|
|
<Polygon>
|
|
<Name>ce_in_p_43</Name>
|
|
<Vertex>
|
|
<Name>ce_in_p_43/V1</Name>
|
|
<Coord X="-8.608" Y="-0.180" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_43/V2</Name>
|
|
<Coord X="-8.608" Y="-4.906" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_43/V3</Name>
|
|
<Coord X="-7.907" Y="-4.906" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_43/V4</Name>
|
|
<Coord X="-6.897" Y="-4.906" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_43/V5</Name>
|
|
<Coord X="-5.969" Y="-4.906" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_43/V6</Name>
|
|
<Coord X="-5.969" Y="-0.180" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<Group>
|
|
<Name>subroom_1</Name>
|
|
<BBox_Min Z="-1.450" Y="-1.435" X="-8.608"></BBox_Min>
|
|
<BBox_Max Z="-1.450" Y="-0.180" X="-5.969"></BBox_Max>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_7</Name>
|
|
<SubId ID="16007"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="-2.447" Y="-4.114" X="-7.289"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_7</Name>
|
|
<SubId ID="14007"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="-0.351" Y="-4.906" X="-8.293"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_008</Name>
|
|
<SubId ID="2008"></SubId>
|
|
<Group>
|
|
<Name>undest_room_008</Name>
|
|
<BBox_Min Z="-2.910" Y="-11.839" X="-5.969"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="-7.110" X="-2.916"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="-2.710" Y="-11.659" X="-5.789"></BBox_Min>
|
|
<BBox_Max Z="-2.710" Y="-7.290" X="-3.096"></BBox_Max>
|
|
<Polygon>
|
|
<Name>ce_in_p_50</Name>
|
|
<Vertex>
|
|
<Name>ce_in_p_50/V1</Name>
|
|
<Coord X="-5.789" Y="-7.290" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_50/V2</Name>
|
|
<Coord X="-5.789" Y="-11.659" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_50/V3</Name>
|
|
<Coord X="-3.096" Y="-11.659" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_50/V4</Name>
|
|
<Coord X="-3.096" Y="-7.290" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_50/V5</Name>
|
|
<Coord X="-3.999" Y="-7.290" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_50/V6</Name>
|
|
<Coord X="-5.009" Y="-7.290" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_8</Name>
|
|
<SubId ID="16008"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="-2.447" Y="-9.518" X="-4.466"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_8</Name>
|
|
<SubId ID="14008"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="-0.349" Y="-11.659" X="-5.413"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_009</Name>
|
|
<SubId ID="2009"></SubId>
|
|
<Group>
|
|
<Name>undest_room_009</Name>
|
|
<BBox_Min Z="-2.910" Y="-11.839" X="-3.096"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="-7.110" X="0.000"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="-2.710" Y="-11.659" X="-2.916"></BBox_Min>
|
|
<BBox_Max Z="-2.710" Y="-7.290" X="-0.180"></BBox_Max>
|
|
<Polygon>
|
|
<Name>ce_in_p_57</Name>
|
|
<Vertex>
|
|
<Name>ce_in_p_57/V1</Name>
|
|
<Coord X="-2.916" Y="-7.290" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_57/V2</Name>
|
|
<Coord X="-2.916" Y="-11.659" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_57/V3</Name>
|
|
<Coord X="-0.180" Y="-11.659" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_57/V4</Name>
|
|
<Coord X="-0.180" Y="-7.290" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_57/V5</Name>
|
|
<Coord X="-1.205" Y="-7.290" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_57/V6</Name>
|
|
<Coord X="-2.215" Y="-7.290" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_9</Name>
|
|
<SubId ID="16009"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="-2.447" Y="-9.520" X="-1.485"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_9</Name>
|
|
<SubId ID="14009"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="-0.349" Y="-11.659" X="-2.592"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_010</Name>
|
|
<SubId ID="2010"></SubId>
|
|
<Group>
|
|
<Name>undest_room_010</Name>
|
|
<BBox_Min Z="-2.910" Y="-7.290" X="-5.969"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="0.000" X="0.000"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="-2.710" Y="-7.110" X="-5.789"></BBox_Min>
|
|
<BBox_Max Z="-2.710" Y="-0.180" X="-0.180"></BBox_Max>
|
|
<Polygon>
|
|
<Name>ce_in_p_64</Name>
|
|
<Vertex>
|
|
<Name>ce_in_p_64/V1</Name>
|
|
<Coord X="-5.789" Y="-0.180" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_64/V2</Name>
|
|
<Coord X="-5.789" Y="-5.450" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_64/V3</Name>
|
|
<Coord X="-5.789" Y="-6.460" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_64/V4</Name>
|
|
<Coord X="-5.789" Y="-7.110" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_64/V5</Name>
|
|
<Coord X="-5.009" Y="-7.110" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_64/V6</Name>
|
|
<Coord X="-3.999" Y="-7.110" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_64/V7</Name>
|
|
<Coord X="-2.215" Y="-7.110" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_64/V8</Name>
|
|
<Coord X="-1.205" Y="-7.110" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_64/V9</Name>
|
|
<Coord X="-0.180" Y="-7.110" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>ce_in_p_64/V10</Name>
|
|
<Coord X="-0.180" Y="-0.180" Z="-2.710"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_10</Name>
|
|
<SubId ID="16010"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="-2.447" Y="-3.916" X="-2.951"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_10</Name>
|
|
<SubId ID="14010"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="-0.349" Y="-0.180" X="-0.665"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
</Group>
|
|
<Group>
|
|
<Name>floor_1</Name>
|
|
<Comment>base_height=0.00</Comment>
|
|
<Switch>
|
|
<Name>SW_room_101</Name>
|
|
<SubId ID="2101"></SubId>
|
|
<Group>
|
|
<Name>undest_room_101</Name>
|
|
<BBox_Min Z="-0.333" Y="-12.515" X="-17.907"></BBox_Min>
|
|
<BBox_Max Z="2.728" Y="-7.110" X="-11.811"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="-11.659" X="-17.660"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="-7.290" X="-11.991"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9896</Name>
|
|
<Vertex>
|
|
<Name>p9896/V1</Name>
|
|
<Coord X="-17.660" Y="-11.659" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9896/V2</Name>
|
|
<Coord X="-11.991" Y="-11.659" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9896/V3</Name>
|
|
<Coord X="-11.991" Y="-7.290" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9896/V4</Name>
|
|
<Coord X="-17.660" Y="-7.290" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0021</Name>
|
|
<SubId ID="11021"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="1.901" Y="-8.087" X="-17.923"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0022</Name>
|
|
<SubId ID="11022"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.017" Y="-9.631" X="-18.000999999999998"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0002</Name>
|
|
<SubId ID="11002"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.181" Y="-12" X="-13.635"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0001</Name>
|
|
<SubId ID="11001"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.165" Y="-11.998" X="-16.537"></Coord>
|
|
<Dir Z="-0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_11</Name>
|
|
<SubId ID="16011"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.263" Y="-9.416" X="-14.967"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_11</Name>
|
|
<SubId ID="14011"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.269" Y="-11.295" X="-17.660"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_102</Name>
|
|
<SubId ID="2102"></SubId>
|
|
<Group>
|
|
<Name>undest_room_102</Name>
|
|
<BBox_Min Z="-0.200" Y="-11.839" X="-11.991"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="-7.110" X="-8.788"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="-11.659" X="-11.811"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="-7.290" X="-8.968"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9897</Name>
|
|
<Vertex>
|
|
<Name>p9897/V1</Name>
|
|
<Coord X="-11.811" Y="-11.659" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9897/V2</Name>
|
|
<Coord X="-8.968" Y="-11.659" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9897/V3</Name>
|
|
<Coord X="-8.968" Y="-7.290" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9897/V4</Name>
|
|
<Coord X="-11.811" Y="-7.290" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0003</Name>
|
|
<SubId ID="11003"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.468" Y="-11.934" X="-10.114"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_12</Name>
|
|
<SubId ID="16012"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.263" Y="-9.401" X="-10.357"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_12</Name>
|
|
<SubId ID="14012"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.362" Y="-7.290" X="-9.429"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_103</Name>
|
|
<SubId ID="2103"></SubId>
|
|
<Group>
|
|
<Name>undest_room_103</Name>
|
|
<BBox_Min Z="-0.200" Y="-11.916" X="-8.968"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="-4.906" X="-5.789"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="-11.659" X="-8.788"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="-5.086" X="-5.969"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9898</Name>
|
|
<Vertex>
|
|
<Name>p9898/V1</Name>
|
|
<Coord X="-8.788" Y="-11.659" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9898/V2</Name>
|
|
<Coord X="-5.969" Y="-11.659" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9898/V3</Name>
|
|
<Coord X="-5.969" Y="-5.086" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9898/V4</Name>
|
|
<Coord X="-8.788" Y="-5.086" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0004</Name>
|
|
<SubId ID="11004"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.151" Y="-12.001999999999999" X="-7.699"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_13</Name>
|
|
<SubId ID="16013"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.263" Y="-8.615" X="-7.303"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_13</Name>
|
|
<SubId ID="14013"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.361" Y="-11.659" X="-6.394"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_104</Name>
|
|
<SubId ID="2104"></SubId>
|
|
<Group>
|
|
<Name>undest_room_104</Name>
|
|
<BBox_Min Z="-0.333" Y="-12.515" X="-5.969"></BBox_Min>
|
|
<BBox_Max Z="2.728" Y="-7.110" X="0.086"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="-11.659" X="-5.789"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="-7.290" X="-0.180"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9899</Name>
|
|
<Vertex>
|
|
<Name>p9899/V1</Name>
|
|
<Coord X="-5.789" Y="-11.659" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9899/V2</Name>
|
|
<Coord X="-0.180" Y="-11.659" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9899/V3</Name>
|
|
<Coord X="-0.180" Y="-7.290" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9899/V4</Name>
|
|
<Coord X="-5.789" Y="-7.290" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0005</Name>
|
|
<SubId ID="11005"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.155" Y="-12" X="-4.721"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0006</Name>
|
|
<SubId ID="11006"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.162" Y="-12" X="-1.81"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0008</Name>
|
|
<SubId ID="11008"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.124" Y="-10.189" X="0.16999999999999998"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_14</Name>
|
|
<SubId ID="16014"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.263" Y="-9.583" X="-3.064"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_14</Name>
|
|
<SubId ID="14014"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.269" Y="-11.288" X="-0.180"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_105</Name>
|
|
<SubId ID="2105"></SubId>
|
|
<Group>
|
|
<Name>undest_room_105</Name>
|
|
<BBox_Min Z="-0.200" Y="-7.290" X="-17.907"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="-4.523" X="-13.871"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="-7.110" X="-17.660"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="-5.086" X="-14.051"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9900</Name>
|
|
<Vertex>
|
|
<Name>p9900/V1</Name>
|
|
<Coord X="-17.660" Y="-7.110" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9900/V2</Name>
|
|
<Coord X="-14.051" Y="-7.110" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9900/V3</Name>
|
|
<Coord X="-14.051" Y="-5.086" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9900/V4</Name>
|
|
<Coord X="-17.660" Y="-5.086" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0020</Name>
|
|
<SubId ID="11020"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.028" Y="-5.383" X="-17.988"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_15</Name>
|
|
<SubId ID="16015"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.263" Y="-6.040" X="-15.971"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_15</Name>
|
|
<SubId ID="14015"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.362" Y="-6.872" X="-17.660"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_106</Name>
|
|
<SubId ID="2106"></SubId>
|
|
<Group>
|
|
<Name>undest_room_106</Name>
|
|
<BBox_Min Z="-0.200" Y="-7.290" X="-14.051"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="-4.906" X="-8.788"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="-7.110" X="-13.871"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="-5.086" X="-8.968"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9901</Name>
|
|
<Vertex>
|
|
<Name>p9901/V1</Name>
|
|
<Coord X="-13.871" Y="-7.110" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9901/V2</Name>
|
|
<Coord X="-8.968" Y="-7.110" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9901/V3</Name>
|
|
<Coord X="-8.968" Y="-5.086" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9901/V4</Name>
|
|
<Coord X="-13.871" Y="-5.086" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_16</Name>
|
|
<SubId ID="16016"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.263" Y="-6.047" X="-11.599"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_16</Name>
|
|
<SubId ID="14016"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.362" Y="-6.911" X="-13.871"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_107</Name>
|
|
<SubId ID="2107"></SubId>
|
|
<Group>
|
|
<Name>undest_room_107</Name>
|
|
<BBox_Min Z="-0.200" Y="-7.290" X="-5.969"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="-3.033" X="-4.304"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="-7.110" X="-5.789"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="-3.213" X="-4.484"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9902</Name>
|
|
<Vertex>
|
|
<Name>p9902/V1</Name>
|
|
<Coord X="-5.789" Y="-7.110" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9902/V2</Name>
|
|
<Coord X="-4.484" Y="-7.110" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9902/V3</Name>
|
|
<Coord X="-4.484" Y="-3.213" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9902/V4</Name>
|
|
<Coord X="-5.789" Y="-3.213" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_17</Name>
|
|
<SubId ID="16017"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.263" Y="-5.114" X="-5.153"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_108</Name>
|
|
<SubId ID="2108"></SubId>
|
|
<Group>
|
|
<Name>undest_room_108</Name>
|
|
<BBox_Min Z="-0.200" Y="-7.290" X="-4.484"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="-4.574" X="0.086"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="-7.110" X="-4.304"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="-5.086" X="-0.180"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9903</Name>
|
|
<Vertex>
|
|
<Name>p9903/V1</Name>
|
|
<Coord X="-4.304" Y="-7.110" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9903/V2</Name>
|
|
<Coord X="-0.180" Y="-7.110" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9903/V3</Name>
|
|
<Coord X="-0.180" Y="-5.086" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9903/V4</Name>
|
|
<Coord X="-4.304" Y="-5.086" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0009</Name>
|
|
<SubId ID="11009"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.126" Y="-5.99" X="0.179"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_18</Name>
|
|
<SubId ID="16018"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.263" Y="-6.059" X="-2.385"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_17</Name>
|
|
<SubId ID="14017"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.362" Y="-6.705" X="-0.180"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_109</Name>
|
|
<SubId ID="2109"></SubId>
|
|
<Group>
|
|
<Name>undest_room_109</Name>
|
|
<BBox_Min Z="-0.333" Y="-5.086" X="-17.907"></BBox_Min>
|
|
<BBox_Max Z="2.728" Y="0.667" X="-11.811"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="-4.906" X="-17.660"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="-0.180" X="-11.991"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9904</Name>
|
|
<Vertex>
|
|
<Name>p9904/V1</Name>
|
|
<Coord X="-17.660" Y="-4.906" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9904/V2</Name>
|
|
<Coord X="-11.991" Y="-4.906" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9904/V3</Name>
|
|
<Coord X="-11.991" Y="-0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9904/V4</Name>
|
|
<Coord X="-17.660" Y="-0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0016</Name>
|
|
<SubId ID="11016"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.117" Y="0.202" X="-13.096"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0017</Name>
|
|
<SubId ID="11017"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.135" Y="0.202" X="-15.989"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0019</Name>
|
|
<SubId ID="11019"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.015" Y="-1.636" X="-17.982"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_19</Name>
|
|
<SubId ID="16019"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.263" Y="-2.624" X="-15.048"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_18</Name>
|
|
<SubId ID="14018"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.362" Y="-0.573" X="-17.660"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_110</Name>
|
|
<SubId ID="2110"></SubId>
|
|
<Group>
|
|
<Name>undest_room_110</Name>
|
|
<BBox_Min Z="-0.200" Y="-5.086" X="-11.991"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="0.000" X="-8.608"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="-4.906" X="-11.811"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="-0.180" X="-8.788"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9905</Name>
|
|
<Vertex>
|
|
<Name>p9905/V1</Name>
|
|
<Coord X="-11.811" Y="-4.906" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9905/V2</Name>
|
|
<Coord X="-8.788" Y="-4.906" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9905/V3</Name>
|
|
<Coord X="-8.788" Y="-0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9905/V4</Name>
|
|
<Coord X="-11.811" Y="-0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0015</Name>
|
|
<SubId ID="11015"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.405" Y="0.135" X="-10.151"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_20</Name>
|
|
<SubId ID="16020"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.263" Y="-2.603" X="-10.288"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_19</Name>
|
|
<SubId ID="14019"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.361" Y="-4.580" X="-11.811"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_111</Name>
|
|
<SubId ID="2111"></SubId>
|
|
<Group>
|
|
<Name>undest_room_111</Name>
|
|
<BBox_Min Z="-0.200" Y="-5.086" X="-8.788"></BBox_Min>
|
|
<BBox_Max Z="3.831" Y="0.000" X="-5.789"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="-4.906" X="-8.788"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="-3.355" X="-5.969"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9918</Name>
|
|
<Vertex>
|
|
<Name>p9918/V1</Name>
|
|
<Coord X="-8.608" Y="-3.373" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9918/V2</Name>
|
|
<Coord X="-8.788" Y="-3.373" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9918/V3</Name>
|
|
<Coord X="-8.788" Y="-4.906" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9918/V4</Name>
|
|
<Coord X="-5.969" Y="-4.906" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9918/V5</Name>
|
|
<Coord X="-5.969" Y="-3.655" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9918/V6</Name>
|
|
<Coord X="-6.998" Y="-3.655" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9918/V7</Name>
|
|
<Coord X="-6.998" Y="-3.861" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9918/V8</Name>
|
|
<Coord X="-7.593" Y="-3.861" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9918/V9</Name>
|
|
<Coord X="-7.592" Y="-3.355" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9918/V10</Name>
|
|
<Coord X="-8.608" Y="-3.355" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<Group>
|
|
<Name>subroom_2</Name>
|
|
<BBox_Min Z="1.260" Y="-1.435" X="-8.608"></BBox_Min>
|
|
<BBox_Max Z="1.260" Y="-0.180" X="-5.969"></BBox_Max>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0014</Name>
|
|
<SubId ID="11014"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.526" Y="0.14100000000000001" X="-7.255"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_21</Name>
|
|
<SubId ID="16021"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.263" Y="-4.393" X="-7.316"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_112</Name>
|
|
<SubId ID="2112"></SubId>
|
|
<Group>
|
|
<Name>undest_room_112</Name>
|
|
<BBox_Min Z="-0.333" Y="-5.089" X="-5.969"></BBox_Min>
|
|
<BBox_Max Z="2.728" Y="0.667" X="0.086"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="-4.906" X="-5.789"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="-0.180" X="-0.180"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9919</Name>
|
|
<Vertex>
|
|
<Name>p9919/V1</Name>
|
|
<Coord X="-5.789" Y="-3.033" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9919/V2</Name>
|
|
<Coord X="-4.304" Y="-3.033" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9919/V3</Name>
|
|
<Coord X="-4.304" Y="-4.906" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9919/V4</Name>
|
|
<Coord X="-0.180" Y="-4.906" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9919/V5</Name>
|
|
<Coord X="-0.180" Y="-0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9919/V6</Name>
|
|
<Coord X="-5.789" Y="-0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0013</Name>
|
|
<SubId ID="11013"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.112" Y="0.20900000000000002" X="-4.161"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0010</Name>
|
|
<SubId ID="11010"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.134" Y="-2.186" X="0.189"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0012</Name>
|
|
<SubId ID="11012"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.087" Y="0.20700000000000002" X="-1.274"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_22</Name>
|
|
<SubId ID="16022"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.263" Y="-2.384" X="-2.829"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_20</Name>
|
|
<SubId ID="14020"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.362" Y="-0.460" X="-0.180"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
</Group>
|
|
<Group>
|
|
<Name>floor_2</Name>
|
|
<Comment>base_height=2.70</Comment>
|
|
<Switch>
|
|
<Name>SW_room_201</Name>
|
|
<SubId ID="2201"></SubId>
|
|
<Group>
|
|
<Name>undest_room_201</Name>
|
|
<BBox_Min Z="2.500" Y="-12.542" X="-18.015"></BBox_Min>
|
|
<BBox_Max Z="6.639" Y="0.695" X="0.202"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="2.700" Y="-11.648" X="-17.660"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="-0.180" X="-0.180"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9934</Name>
|
|
<Vertex>
|
|
<Name>p9934/V1</Name>
|
|
<Coord X="-17.660" Y="-11.648" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9934/V2</Name>
|
|
<Coord X="-0.180" Y="-11.648" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9934/V3</Name>
|
|
<Coord X="-0.180" Y="-0.180" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9934/V4</Name>
|
|
<Coord X="-5.789" Y="-0.180" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9934/V5</Name>
|
|
<Coord X="-5.789" Y="-3.655" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9934/V6</Name>
|
|
<Coord X="-6.998" Y="-3.655" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9934/V7</Name>
|
|
<Coord X="-6.998" Y="-3.861" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9934/V8</Name>
|
|
<Coord X="-8.794" Y="-3.861" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9934/V9</Name>
|
|
<Coord X="-8.794" Y="-0.180" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9934/V10</Name>
|
|
<Coord X="-17.660" Y="-0.191" Z="2.700"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0023</Name>
|
|
<SubId ID="11023"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="4.492" Y="-5.931" X="-17.916999999999998"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0011</Name>
|
|
<SubId ID="11011"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="4.592" Y="-5.924" X="0.107"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0018</Name>
|
|
<SubId ID="11018"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="4.90126" Y="-1.52" X="-9.818"></Coord>
|
|
<Dir Z="0.866" Y="0.500" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0007</Name>
|
|
<SubId ID="11007"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="4.92026" Y="-9.958" X="-10.657"></Coord>
|
|
<Dir Z="0.866" Y="-0.500" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_23</Name>
|
|
<SubId ID="16023"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="2.963" Y="-5.900" X="-9.320"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_21</Name>
|
|
<SubId ID="14021"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="4.788" Y="-6.891" X="-0.180"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
</Group>
|
|
<Group>
|
|
<Name>floor_3</Name>
|
|
<Comment>base_height=6.64</Comment>
|
|
<Switch>
|
|
<Name>SW_room_301</Name>
|
|
<SubId ID="2301"></SubId>
|
|
<Group>
|
|
<Name>undest_room_301</Name>
|
|
<BBox_Min Z="2.663" Y="-12.542" X="-18.015"></BBox_Min>
|
|
<BBox_Max Z="6.639" Y="0.695" X="0.202"></BBox_Max>
|
|
</Group>
|
|
</Switch>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>ZEG_MOD_AP_1</Name>
|
|
<SubId ID="12001"></SubId>
|
|
<Model NAME="ZEG_01.flt"></Model>
|
|
<Coord Z="2.450" Y="0.100" X="-0.100"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_1</Name>
|
|
<SubId ID="15001"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="-2.500" X="1.070"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_2</Name>
|
|
<SubId ID="15002"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="-5.920" X="1.070"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_3</Name>
|
|
<SubId ID="15003"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="-9.339" X="1.070"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_4</Name>
|
|
<SubId ID="15004"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="-12.909" X="-2.500"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_5</Name>
|
|
<SubId ID="15005"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="-12.909" X="-6.780"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_6</Name>
|
|
<SubId ID="15006"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="-12.909" X="-11.060"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_7</Name>
|
|
<SubId ID="15007"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="-12.909" X="-15.340"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_8</Name>
|
|
<SubId ID="15008"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="-9.339" X="-18.910"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_9</Name>
|
|
<SubId ID="15009"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="-5.920" X="-18.910"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_10</Name>
|
|
<SubId ID="15010"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="-2.500" X="-18.910"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_11</Name>
|
|
<SubId ID="15011"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="1.070" X="-15.000"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_12</Name>
|
|
<SubId ID="15012"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="1.070" X="-10.833"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_13</Name>
|
|
<SubId ID="15013"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="1.070" X="-6.667"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_14</Name>
|
|
<SubId ID="15014"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="1.070" X="-2.500"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>BDI_P_1</Name>
|
|
<SubId ID="27001"></SubId>
|
|
<Model NAME="BDI.flt"></Model>
|
|
<Coord Z="-2.113" Y="-6.711" X="-11.711"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>BDI_P_2</Name>
|
|
<SubId ID="27002"></SubId>
|
|
<Model NAME="BDI.flt"></Model>
|
|
<Coord Z="0.600" Y="-4.389" X="-11.711"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Header>
|
|
</STREIF> |