Files
qt6-migration-pipeline/external/BuildingModels/StaticMeshes/bldg_1173.flt.xml
T
2026-10-23 16:13:31 +00:00

467 lines
24 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Thu Nov 04 11:12:22 2021 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_1173</Name>
<ModelId Id="1173"></ModelId>
<BBox_Min Z="-0.200" Y="-7.080" X="-7.068"></BBox_Min>
<BBox_Max Z="5.973" Y="1.070" X="1.070"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="-6.010" X="-5.998"></BBox_Min>
<BBox_Max Z="0.000" Y="0.000" X="0.000"></BBox_Max>
<Polygon>
<Name>p2945</Name>
<Vertex>
<Name>p2945/V1</Name>
<Coord X="-5.998" Y="-6.010" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2945/V2</Name>
<Coord X="0.000" Y="-6.010" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2945/V3</Name>
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2945/V4</Name>
<Coord X="-5.998" Y="0.000" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0.00</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.200" Y="-4.312" X="-3.287"></BBox_Min>
<BBox_Max Z="3.771" Y="0.000" X="0.725"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="-3.911" X="-3.107"></BBox_Min>
<BBox_Max Z="0.000" Y="-0.180" X="-0.180"></BBox_Max>
<Polygon>
<Name>p2936</Name>
<Vertex>
<Name>p2936/V1</Name>
<Coord X="-0.180" Y="-0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2936/V2</Name>
<Coord X="-3.107" Y="-0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2936/V3</Name>
<Coord X="-3.107" Y="-3.911" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2936/V4</Name>
<Coord X="-0.180" Y="-3.911" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>subroom_1</Name>
<BBox_Min Z="0.000" Y="-1.214" X="-2.699"></BBox_Min>
<BBox_Max Z="0.707" Y="-0.180" X="-1.497"></BBox_Max>
</Group>
<Group>
<Name>subroom_2</Name>
<BBox_Min Z="0.707" Y="-1.297" X="-3.107"></BBox_Min>
<BBox_Max Z="0.707" Y="-0.180" X="-2.016"></BBox_Max>
</Group>
<Group>
<Name>subroom_3</Name>
<BBox_Min Z="0.707" Y="-1.716" X="-3.107"></BBox_Min>
<BBox_Max Z="1.251" Y="-0.431" X="-2.079"></BBox_Max>
</Group>
<Group>
<Name>subroom_4</Name>
<BBox_Min Z="1.251" Y="-3.913" X="-3.107"></BBox_Min>
<BBox_Max Z="2.680" Y="-1.716" X="-2.079"></BBox_Max>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0006</Name>
<SubId ID="11006"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.304" Y="-2.113" X="0.13"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.378" Y="0.096" X="-1.174"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-2.046" X="-1.644"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_102</Name>
<SubId ID="2102"></SubId>
<Group>
<Name>undest_room_102</Name>
<BBox_Min Z="-0.200" Y="-3.817" X="-6.744"></BBox_Min>
<BBox_Max Z="2.835" Y="0.066" X="-3.107"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="-3.637" X="-5.818"></BBox_Min>
<BBox_Max Z="0.000" Y="-0.180" X="-3.287"></BBox_Max>
<Polygon>
<Name>p2937</Name>
<Vertex>
<Name>p2937/V1</Name>
<Coord X="-3.287" Y="-0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2937/V2</Name>
<Coord X="-5.818" Y="-0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2937/V3</Name>
<Coord X="-5.818" Y="-3.637" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2937/V4</Name>
<Coord X="-3.287" Y="-3.637" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0008</Name>
<SubId ID="11008"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.031" Y="-1.293" X="-6.167000000000001"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.129" Y="0.16999999999999998" X="-4.182"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.909" X="-4.553"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.148" Y="-0.836" X="-4.081"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_103</Name>
<SubId ID="2103"></SubId>
<Group>
<Name>undest_room_103</Name>
<BBox_Min Z="-0.200" Y="-6.010" X="-6.744"></BBox_Min>
<BBox_Max Z="2.835" Y="-3.367" X="0.725"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="-5.830" X="-5.818"></BBox_Min>
<BBox_Max Z="0.000" Y="-3.637" X="-0.180"></BBox_Max>
<Polygon>
<Name>p2938</Name>
<Vertex>
<Name>p2938/V1</Name>
<Coord X="-0.180" Y="-4.091" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2938/V2</Name>
<Coord X="-0.283" Y="-4.091" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2938/V3</Name>
<Coord X="-0.283" Y="-3.911" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2938/V4</Name>
<Coord X="-1.294" Y="-3.911" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2938/V5</Name>
<Coord X="-1.294" Y="-4.091" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2938/V6</Name>
<Coord X="-3.287" Y="-4.091" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2938/V7</Name>
<Coord X="-3.287" Y="-3.817" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2938/V8</Name>
<Coord X="-4.533" Y="-3.817" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2938/V9</Name>
<Coord X="-4.533" Y="-3.637" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2938/V10</Name>
<Coord X="-5.552" Y="-3.637" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2938/V11</Name>
<Coord X="-5.552" Y="-3.817" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2938/V12</Name>
<Coord X="-5.818" Y="-3.817" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2938/V13</Name>
<Coord X="-5.818" Y="-5.830" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2938/V14</Name>
<Coord X="-0.180" Y="-5.830" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0004</Name>
<SubId ID="11004"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.972" Y="-6.1370000000000005" X="-4.387"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0005</Name>
<SubId ID="11005"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.282" Y="-5" X="0.131"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0009</Name>
<SubId ID="11009"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.037" Y="-4.217" X="-6.173"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_3</Name>
<SubId ID="16003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-4.961" X="-3.095"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_2</Name>
<SubId ID="14002"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.178" Y="-5.517" X="-5.818"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_3</Name>
<SubId ID="14003"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.178" Y="-5.830" X="-0.569"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=2.68</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.490" Y="-6.215" X="-6.774"></BBox_Min>
<BBox_Max Z="5.973" Y="0.205" X="0.756"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.680" Y="-5.830" X="-5.818"></BBox_Min>
<BBox_Max Z="2.680" Y="-0.180" X="-0.180"></BBox_Max>
<Polygon>
<Name>p2940</Name>
<Vertex>
<Name>p2940/V1</Name>
<Coord X="-0.180" Y="-5.830" Z="2.680"></Coord>
</Vertex>
<Vertex>
<Name>p2940/V2</Name>
<Coord X="-0.180" Y="-0.180" Z="2.680"></Coord>
</Vertex>
<Vertex>
<Name>p2940/V3</Name>
<Coord X="-5.818" Y="-0.180" Z="2.680"></Coord>
</Vertex>
<Vertex>
<Name>p2940/V4</Name>
<Coord X="-5.818" Y="-5.830" Z="2.680"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>subroom_5</Name>
<BBox_Min Z="2.680" Y="-5.830" X="-5.818"></BBox_Min>
<BBox_Max Z="2.680" Y="-3.911" X="-0.180"></BBox_Max>
</Group>
<Group>
<Name>subroom_6</Name>
<BBox_Min Z="2.680" Y="-3.911" X="-5.818"></BBox_Min>
<BBox_Max Z="2.680" Y="-0.180" X="-3.107"></BBox_Max>
</Group>
<Group>
<Name>subroom_7</Name>
<BBox_Min Z="2.680" Y="-3.911" X="-2.079"></BBox_Min>
<BBox_Max Z="2.680" Y="-0.180" X="-0.180"></BBox_Max>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0007</Name>
<SubId ID="11007"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="5.05226" Y="-3.658" X="-0.87127"></Coord>
<Dir Z="0.766" Y="-0.000" X="0.643"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0010</Name>
<SubId ID="11010"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.89226" Y="-2.358" X="-5.05973"></Coord>
<Dir Z="0.766" Y="-0.000" X="-0.643"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0003</Name>
<SubId ID="11003"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.331" Y="0.099" X="-3.06"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_4</Name>
<SubId ID="14004"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.698" Y="-5.830" X="-2.525"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_4</Name>
<SubId ID="16004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="2.980" Y="-3.005" X="-4.409"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_5</Name>
<SubId ID="16005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="2.980" Y="-3.005" X="-1.290"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_3</Name>
<Comment>base_height=5.97</Comment>
<Switch>
<Name>SW_room_301</Name>
<SubId ID="2301"></SubId>
<Group>
<Name>undest_room_301</Name>
<BBox_Min Z="2.808" Y="-6.215" X="-6.644"></BBox_Min>
<BBox_Max Z="5.973" Y="0.204" X="0.626"></BBox_Max>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="2.430" Y="-0.100" X="0.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.000" X="-1.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.000" X="-4.498"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.500" X="-6.998"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-4.510" X="-6.998"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_5</Name>
<SubId ID="15005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-7.010" X="-4.498"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_6</Name>
<SubId ID="15006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-7.010" X="-1.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_7</Name>
<SubId ID="15007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-4.510" X="1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_8</Name>
<SubId ID="15008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.500" X="1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.400" Y="-3.811" X="-1.863"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>