<?xml version="1.0" ?>
|
|
<!--fltHdrLastDate Mon Dec 20 14:21:27 2021 - PostProcessed by SLTE $Rev: 56086 $-->
|
|
<STREIF>
|
|
<Header>
|
|
<Group>
|
|
<Name>bldg_1242</Name>
|
|
<ModelId Id="1242"></ModelId>
|
|
<BBox_Min Z="-0.200" Y="-1.070" X="-2.430"></BBox_Min>
|
|
<BBox_Max Z="6.588" Y="10.140" X="4.090"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="0.000" X="-1.317"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="9.005" X="3.011"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p2351</Name>
|
|
<Vertex>
|
|
<Name>p2351/V1</Name>
|
|
<Coord X="2.921" Y="0.000" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2351/V2</Name>
|
|
<Coord X="2.921" Y="5.981" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2351/V3</Name>
|
|
<Coord X="3.011" Y="5.981" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2351/V4</Name>
|
|
<Coord X="3.011" Y="9.005" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2351/V5</Name>
|
|
<Coord X="0.000" Y="9.005" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2351/V6</Name>
|
|
<Coord X="0.000" Y="7.371" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2351/V7</Name>
|
|
<Coord X="-1.317" Y="7.371" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2351/V8</Name>
|
|
<Coord X="-1.317" Y="0.000" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<Group>
|
|
<Name>floor_1</Name>
|
|
<Comment>base_height=0.00</Comment>
|
|
<Switch>
|
|
<Name>SW_room_101</Name>
|
|
<SubId ID="2101"></SubId>
|
|
<Group>
|
|
<Name>undest_room_101</Name>
|
|
<BBox_Min Z="-0.200" Y="0.000" X="-0.001"></BBox_Min>
|
|
<BBox_Max Z="2.710" Y="4.610" X="2.921"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="0.180" X="0.180"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="4.430" X="2.831"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p3905</Name>
|
|
<Vertex>
|
|
<Name>p3905/V1</Name>
|
|
<Coord X="2.831" Y="4.430" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3905/V2</Name>
|
|
<Coord X="0.180" Y="4.430" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3905/V3</Name>
|
|
<Coord X="0.180" Y="0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3905/V4</Name>
|
|
<Coord X="2.831" Y="0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0006</Name>
|
|
<SubId ID="11006"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.368" Y="-0.104" X="1.736"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_1</Name>
|
|
<SubId ID="16001"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="2.351" X="1.455"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_1</Name>
|
|
<SubId ID="14001"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.266" Y="4.430" X="2.423"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_8</Name>
|
|
<SubId ID="14008"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.266" Y="3.115" X="0.180"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_102</Name>
|
|
<SubId ID="2102"></SubId>
|
|
<Group>
|
|
<Name>undest_room_102</Name>
|
|
<BBox_Min Z="-0.200" Y="4.430" X="0.000"></BBox_Min>
|
|
<BBox_Max Z="2.711" Y="9.071" X="3.143"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="4.610" X="0.180"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="8.825" X="2.831"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p3906</Name>
|
|
<Vertex>
|
|
<Name>p3906/V1</Name>
|
|
<Coord X="0.180" Y="4.610" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3906/V2</Name>
|
|
<Coord X="2.831" Y="4.610" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3906/V3</Name>
|
|
<Coord X="2.831" Y="8.825" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3906/V4</Name>
|
|
<Coord X="0.180" Y="8.825" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0004</Name>
|
|
<SubId ID="11004"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.133" Y="9.199" X="2.056"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0001</Name>
|
|
<SubId ID="11001"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.016" Y="7.946" X="3.11"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_2</Name>
|
|
<SubId ID="16002"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="6.825" X="1.531"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_2</Name>
|
|
<SubId ID="14002"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.266" Y="4.610" X="0.776"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_103</Name>
|
|
<SubId ID="2103"></SubId>
|
|
<Group>
|
|
<Name>undest_room_103</Name>
|
|
<BBox_Min Z="-0.200" Y="0.000" X="-1.317"></BBox_Min>
|
|
<BBox_Max Z="3.638" Y="7.371" X="0.180"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="0.000" X="-1.137"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="7.191" X="0.000"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p3907</Name>
|
|
<Vertex>
|
|
<Name>p3907/V1</Name>
|
|
<Coord X="0.000" Y="7.191" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3907/V2</Name>
|
|
<Coord X="-1.137" Y="7.191" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3907/V3</Name>
|
|
<Coord X="-1.137" Y="0.000" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3907/V4</Name>
|
|
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_3</Name>
|
|
<SubId ID="16003"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="5.768" X="-0.571"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_4</Name>
|
|
<SubId ID="16004"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="0.881" X="-0.530"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_7</Name>
|
|
<SubId ID="14007"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.266" Y="5.867" X="0.000"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
</Group>
|
|
<Group>
|
|
<Name>floor_2</Name>
|
|
<Comment>base_height=2.71</Comment>
|
|
<Switch>
|
|
<Name>SW_room_201</Name>
|
|
<SubId ID="2201"></SubId>
|
|
<Group>
|
|
<Name>undest_room_201</Name>
|
|
<BBox_Min Z="2.510" Y="0.000" X="-0.001"></BBox_Min>
|
|
<BBox_Max Z="5.509" Y="4.610" X="3.369"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="2.710" Y="0.180" X="0.180"></BBox_Min>
|
|
<BBox_Max Z="2.710" Y="4.430" X="2.831"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p3705</Name>
|
|
<Vertex>
|
|
<Name>p3705/V1</Name>
|
|
<Coord X="2.831" Y="4.430" Z="2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3705/V2</Name>
|
|
<Coord X="0.180" Y="4.430" Z="2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3705/V3</Name>
|
|
<Coord X="0.180" Y="0.180" Z="2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3705/V4</Name>
|
|
<Coord X="2.831" Y="0.180" Z="2.710"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0002</Name>
|
|
<SubId ID="11002"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="5.074" Y="1.777" X="3.145"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0007</Name>
|
|
<SubId ID="11007"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="3.381" Y="-0.094" X="1.431"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_5</Name>
|
|
<SubId ID="16005"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="3.084" Y="2.203" X="1.491"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_3</Name>
|
|
<SubId ID="14003"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="5.022" Y="0.180" X="0.662"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_202</Name>
|
|
<SubId ID="2202"></SubId>
|
|
<Group>
|
|
<Name>undest_room_202</Name>
|
|
<BBox_Min Z="2.510" Y="4.430" X="0.000"></BBox_Min>
|
|
<BBox_Max Z="5.509" Y="9.005" X="3.369"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="2.710" Y="4.610" X="0.180"></BBox_Min>
|
|
<BBox_Max Z="2.710" Y="8.825" X="2.831"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p3704</Name>
|
|
<Vertex>
|
|
<Name>p3704/V1</Name>
|
|
<Coord X="0.180" Y="8.825" Z="2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3704/V2</Name>
|
|
<Coord X="0.180" Y="4.610" Z="2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3704/V3</Name>
|
|
<Coord X="2.831" Y="4.610" Z="2.710"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3704/V4</Name>
|
|
<Coord X="2.831" Y="8.825" Z="2.710"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0005</Name>
|
|
<SubId ID="11005"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="3.502" Y="9.136" X="1.402"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0003</Name>
|
|
<SubId ID="11003"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="5.022" Y="6.721" X="3.0989999999999998"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_6</Name>
|
|
<SubId ID="16006"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="3.084" Y="6.874" X="1.472"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_4</Name>
|
|
<SubId ID="14004"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="5.022" Y="8.825" X="2.539"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_203</Name>
|
|
<SubId ID="2203"></SubId>
|
|
<Group>
|
|
<Name>undest_room_203</Name>
|
|
<BBox_Min Z="2.510" Y="0.000" X="-1.317"></BBox_Min>
|
|
<BBox_Max Z="6.389" Y="7.371" X="0.369"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="2.711" Y="0.000" X="-1.137"></BBox_Min>
|
|
<BBox_Max Z="2.711" Y="7.192" X="0.000"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p3698</Name>
|
|
<Vertex>
|
|
<Name>p3698/V1</Name>
|
|
<Coord X="0.000" Y="7.192" Z="2.711"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3698/V2</Name>
|
|
<Coord X="-1.137" Y="7.192" Z="2.711"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3698/V3</Name>
|
|
<Coord X="-1.137" Y="0.000" Z="2.711"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3698/V4</Name>
|
|
<Coord X="0.000" Y="0.000" Z="2.711"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<Group>
|
|
<Name>subroom_1</Name>
|
|
<BBox_Min Z="2.711" Y="0.000" X="-1.137"></BBox_Min>
|
|
<BBox_Max Z="2.711" Y="1.510" X="0.000"></BBox_Max>
|
|
</Group>
|
|
<Group>
|
|
<Name>subroom_2</Name>
|
|
<BBox_Min Z="2.711" Y="5.681" X="-1.137"></BBox_Min>
|
|
<BBox_Max Z="2.711" Y="7.192" X="0.000"></BBox_Max>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_7</Name>
|
|
<SubId ID="16007"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="3.084" Y="6.420" X="-0.565"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_8</Name>
|
|
<SubId ID="16008"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="3.084" Y="0.780" X="-0.582"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_5</Name>
|
|
<SubId ID="14005"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="5.022" Y="5.949" X="0.000"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_6</Name>
|
|
<SubId ID="14006"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="5.022" Y="1.350" X="0.000"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
</Group>
|
|
<Group>
|
|
<Name>floor_3</Name>
|
|
<Comment>base_height=5.4</Comment>
|
|
<Switch>
|
|
<Name>SW_room_301</Name>
|
|
<SubId ID="2301"></SubId>
|
|
<Group>
|
|
<Name>undest_room_301</Name>
|
|
<BBox_Min Z="5.196" Y="0.000" X="0.000"></BBox_Min>
|
|
<BBox_Max Z="6.588" Y="9.005" X="3.369"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="5.403" Y="0.180" X="0.180"></BBox_Min>
|
|
<BBox_Max Z="5.403" Y="8.825" X="3.011"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p3423</Name>
|
|
<Vertex>
|
|
<Name>p3423/V1</Name>
|
|
<Coord X="0.180" Y="0.180" Z="5.403"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3423/V2</Name>
|
|
<Coord X="3.011" Y="0.180" Z="5.403"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3423/V3</Name>
|
|
<Coord X="3.011" Y="8.825" Z="5.403"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3423/V4</Name>
|
|
<Coord X="0.180" Y="8.825" Z="5.403"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_9</Name>
|
|
<SubId ID="16009"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="5.777" Y="4.406" X="1.409"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_302</Name>
|
|
<SubId ID="2302"></SubId>
|
|
<Group>
|
|
<Name>undest_room_302</Name>
|
|
<BBox_Min Z="5.309" Y="0.000" X="-1.317"></BBox_Min>
|
|
<BBox_Max Z="6.588" Y="7.371" X="0.180"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="5.509" Y="0.000" X="-1.137"></BBox_Min>
|
|
<BBox_Max Z="5.509" Y="7.191" X="0.000"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p3424</Name>
|
|
<Vertex>
|
|
<Name>p3424/V1</Name>
|
|
<Coord X="0.000" Y="7.191" Z="5.509"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3424/V2</Name>
|
|
<Coord X="-1.137" Y="7.191" Z="5.509"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3424/V3</Name>
|
|
<Coord X="-1.137" Y="0.000" Z="5.509"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3424/V4</Name>
|
|
<Coord X="0.000" Y="0.000" Z="5.509"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<Group>
|
|
<Name>subroom_3</Name>
|
|
<BBox_Min Z="5.509" Y="5.681" X="-1.137"></BBox_Min>
|
|
<BBox_Max Z="5.509" Y="7.191" X="0.000"></BBox_Max>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_10</Name>
|
|
<SubId ID="16010"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="5.777" Y="6.488" X="-0.609"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>ZEG_MOD_AP_1</Name>
|
|
<SubId ID="12001"></SubId>
|
|
<Model NAME="ZEG_01.flt"></Model>
|
|
<Coord Z="2.260" Y="-0.100" X="0.100"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_1</Name>
|
|
<SubId ID="15001"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="2.500" X="-2.360"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_2</Name>
|
|
<SubId ID="15002"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="6.500" X="-2.360"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_3</Name>
|
|
<SubId ID="15003"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="10.070" X="0.500"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_4</Name>
|
|
<SubId ID="15004"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="6.509" X="4.020"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_5</Name>
|
|
<SubId ID="15005"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="2.500" X="4.020"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_6</Name>
|
|
<SubId ID="15006"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="-1.000" X="0.880"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>BDI_P_1</Name>
|
|
<SubId ID="27001"></SubId>
|
|
<Model NAME="BDI.flt"></Model>
|
|
<Coord Z="3.399" Y="3.735" X="2.731"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>BDI_P_2</Name>
|
|
<SubId ID="27002"></SubId>
|
|
<Model NAME="BDI.flt"></Model>
|
|
<Coord Z="0.550" Y="4.710" X="0.441"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Header>
|
|
</STREIF> |