542 lines
27 KiB
XML
Executable File
542 lines
27 KiB
XML
Executable File
<?xml version="1.0" ?>
|
|
<!--fltHdrLastDate Wed Dec 01 14:32:13 2021 - PostProcessed by SLTE $Rev: 56086 $-->
|
|
<STREIF>
|
|
<Header>
|
|
<Group>
|
|
<Name>bldg_1264</Name>
|
|
<ModelId Id="1264"></ModelId>
|
|
<BBox_Min Z="-0.200" Y="-1.116" X="-1.140"></BBox_Min>
|
|
<BBox_Max Z="9.185" Y="13.140" X="4.336"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="0.000" X="0.000"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="12.031" X="3.112"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p3055</Name>
|
|
<Vertex>
|
|
<Name>p3055/V1</Name>
|
|
<Coord X="0.000" Y="12.031" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3055/V2</Name>
|
|
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3055/V3</Name>
|
|
<Coord X="3.112" Y="0.000" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3055/V4</Name>
|
|
<Coord X="3.112" Y="12.031" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<Group>
|
|
<Name>floor_1</Name>
|
|
<Comment>base_height=0.00</Comment>
|
|
<Switch>
|
|
<Name>SW_room_101</Name>
|
|
<SubId ID="2101"></SubId>
|
|
<Group>
|
|
<Name>undest_room_101</Name>
|
|
<BBox_Min Z="-0.200" Y="-0.131" X="0.000"></BBox_Min>
|
|
<BBox_Max Z="3.779" Y="6.955" X="3.112"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="-0.000" Y="0.180" X="0.090"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="6.775" X="2.932"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p2906</Name>
|
|
<Vertex>
|
|
<Name>p2906/V1</Name>
|
|
<Coord X="2.932" Y="6.775" Z="-0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2906/V2</Name>
|
|
<Coord X="0.090" Y="6.775" Z="-0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2906/V3</Name>
|
|
<Coord X="0.090" Y="0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2906/V4</Name>
|
|
<Coord X="2.932" Y="0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0003</Name>
|
|
<SubId ID="11003"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="1.803" Y="1.056" X="3.315"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0001</Name>
|
|
<SubId ID="11001"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.405" Y="-0.115" X="1.767"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_1</Name>
|
|
<SubId ID="16001"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="3.477" X="1.511"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_1</Name>
|
|
<SubId ID="14001"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.244" Y="0.181" X="1.446"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_102</Name>
|
|
<SubId ID="2102"></SubId>
|
|
<Group>
|
|
<Name>undest_room_102</Name>
|
|
<BBox_Min Z="-0.200" Y="6.767" X="-0.000"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="9.395" X="3.194"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="6.955" X="0.090"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="9.215" X="2.932"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p2907</Name>
|
|
<Vertex>
|
|
<Name>p2907/V1</Name>
|
|
<Coord X="2.932" Y="9.215" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2907/V2</Name>
|
|
<Coord X="0.090" Y="9.215" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2907/V3</Name>
|
|
<Coord X="0.090" Y="6.955" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2907/V4</Name>
|
|
<Coord X="2.932" Y="6.955" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0004</Name>
|
|
<SubId ID="11004"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.002" Y="7.691" X="3.375"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_2</Name>
|
|
<SubId ID="16002"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="8.085" X="1.511"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_2</Name>
|
|
<SubId ID="14002"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.207" Y="9.215" X="2.387"></Coord>
|
|
<Dir Z="-0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_103</Name>
|
|
<SubId ID="2103"></SubId>
|
|
<Group>
|
|
<Name>undest_room_103</Name>
|
|
<BBox_Min Z="-0.200" Y="9.208" X="-0.000"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="12.189" X="3.112"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="9.395" X="0.090"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="11.851" X="2.932"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p2908</Name>
|
|
<Vertex>
|
|
<Name>p2908/V1</Name>
|
|
<Coord X="2.932" Y="11.851" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2908/V2</Name>
|
|
<Coord X="0.090" Y="11.851" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2908/V3</Name>
|
|
<Coord X="0.090" Y="9.395" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2908/V4</Name>
|
|
<Coord X="2.932" Y="9.395" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0009</Name>
|
|
<SubId ID="11009"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="1.991" Y="12.197999999999999" X="1.718"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0005</Name>
|
|
<SubId ID="11005"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.227" Y="10.611" X="3.307"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_3</Name>
|
|
<SubId ID="16003"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="10.623" X="1.511"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_3</Name>
|
|
<SubId ID="14003"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.316" Y="9.395" X="2.649"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
</Group>
|
|
<Group>
|
|
<Name>floor_2</Name>
|
|
<Comment>base_height=2.7</Comment>
|
|
<Switch>
|
|
<Name>SW_room_201</Name>
|
|
<SubId ID="2201"></SubId>
|
|
<Group>
|
|
<Name>undest_room_201</Name>
|
|
<BBox_Min Z="2.500" Y="-0.335" X="-0.000"></BBox_Min>
|
|
<BBox_Max Z="5.544" Y="6.955" X="3.112"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="2.700" Y="0.180" X="0.090"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="6.775" X="2.932"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p2931</Name>
|
|
<Vertex>
|
|
<Name>p2931/V1</Name>
|
|
<Coord X="2.932" Y="6.775" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2931/V2</Name>
|
|
<Coord X="0.090" Y="6.775" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2931/V3</Name>
|
|
<Coord X="0.090" Y="0.180" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2931/V4</Name>
|
|
<Coord X="2.932" Y="0.180" Z="2.700"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<Group>
|
|
<Name>subroom_1</Name>
|
|
<BBox_Min Z="2.700" Y="0.180" X="0.090"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="1.478" X="2.932"></BBox_Max>
|
|
</Group>
|
|
<Group>
|
|
<Name>subroom_2</Name>
|
|
<BBox_Min Z="2.700" Y="1.478" X="1.207"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="6.775" X="2.932"></BBox_Max>
|
|
</Group>
|
|
<Group>
|
|
<Name>subroom_3</Name>
|
|
<BBox_Min Z="2.700" Y="5.415" X="0.090"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="6.775" X="1.207"></BBox_Max>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0006</Name>
|
|
<SubId ID="11006"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="4.427" Y="4.025" X="3.314"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0002</Name>
|
|
<SubId ID="11002"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="3.487" Y="-0.116" X="1.547"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_4</Name>
|
|
<SubId ID="14004"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="4.907" Y="6.775" X="0.698"></Coord>
|
|
<Dir Z="-0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_4</Name>
|
|
<SubId ID="16004"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="3.000" Y="3.477" X="1.900"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_202</Name>
|
|
<SubId ID="2202"></SubId>
|
|
<Group>
|
|
<Name>undest_room_202</Name>
|
|
<BBox_Min Z="2.500" Y="6.775" X="-0.000"></BBox_Min>
|
|
<BBox_Max Z="5.992" Y="9.395" X="3.112"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="2.700" Y="6.955" X="0.090"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="9.215" X="2.932"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p2936</Name>
|
|
<Vertex>
|
|
<Name>p2936/V1</Name>
|
|
<Coord X="0.090" Y="6.955" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2936/V2</Name>
|
|
<Coord X="2.932" Y="6.955" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2936/V3</Name>
|
|
<Coord X="2.932" Y="9.215" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2936/V4</Name>
|
|
<Coord X="0.090" Y="9.215" Z="2.700"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0007</Name>
|
|
<SubId ID="11007"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="3.356" Y="8.034" X="3.307"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_5</Name>
|
|
<SubId ID="14005"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="4.907" Y="7.196" X="2.932"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_5</Name>
|
|
<SubId ID="16005"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="3.000" Y="8.085" X="1.511"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_203</Name>
|
|
<SubId ID="2203"></SubId>
|
|
<Group>
|
|
<Name>undest_room_203</Name>
|
|
<BBox_Min Z="2.500" Y="9.215" X="-0.000"></BBox_Min>
|
|
<BBox_Max Z="5.460" Y="12.407" X="3.112"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="2.700" Y="9.395" X="0.090"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="11.851" X="2.932"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p2937</Name>
|
|
<Vertex>
|
|
<Name>p2937/V1</Name>
|
|
<Coord X="0.090" Y="9.395" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2937/V2</Name>
|
|
<Coord X="2.932" Y="9.395" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2937/V3</Name>
|
|
<Coord X="2.932" Y="11.851" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p2937/V4</Name>
|
|
<Coord X="0.090" Y="11.851" Z="2.700"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0010</Name>
|
|
<SubId ID="11010"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="3.364" Y="12.122" X="1.462"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0008</Name>
|
|
<SubId ID="11008"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="4.414" Y="10.621" X="3.306"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_6</Name>
|
|
<SubId ID="14006"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="4.907" Y="11.851" X="2.334"></Coord>
|
|
<Dir Z="-0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_6</Name>
|
|
<SubId ID="16006"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="3.000" Y="10.623" X="1.511"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
</Group>
|
|
<Group>
|
|
<Name>floor_3</Name>
|
|
<Comment>base_height=5.46</Comment>
|
|
<Switch>
|
|
<Name>SW_room_301</Name>
|
|
<SubId ID="2301"></SubId>
|
|
<Group>
|
|
<Name>undest_room_301</Name>
|
|
<BBox_Min Z="5.184" Y="-0.351" X="-0.000"></BBox_Min>
|
|
<BBox_Max Z="9.185" Y="12.378" X="3.112"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="5.460" Y="-0.000" X="0.090"></BBox_Min>
|
|
<BBox_Max Z="5.460" Y="12.031" X="2.932"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p3031</Name>
|
|
<Vertex>
|
|
<Name>p3031/V1</Name>
|
|
<Coord X="0.090" Y="-0.000" Z="5.460"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3031/V2</Name>
|
|
<Coord X="2.932" Y="-0.000" Z="5.460"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3031/V3</Name>
|
|
<Coord X="2.932" Y="12.031" Z="5.460"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p3031/V4</Name>
|
|
<Coord X="0.090" Y="12.031" Z="5.460"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<Group>
|
|
<Name>subroom_4</Name>
|
|
<BBox_Min Z="5.382" Y="-0.000" X="0.090"></BBox_Min>
|
|
<BBox_Max Z="5.544" Y="5.830" X="2.932"></BBox_Max>
|
|
</Group>
|
|
<Group>
|
|
<Name>subroom_5</Name>
|
|
<BBox_Min Z="5.389" Y="5.824" X="0.090"></BBox_Min>
|
|
<BBox_Max Z="5.544" Y="12.031" X="2.932"></BBox_Max>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_7</Name>
|
|
<SubId ID="16007"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="5.760" Y="6.015" X="1.511"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>ZEG_MOD_AP_1</Name>
|
|
<SubId ID="12001"></SubId>
|
|
<Model NAME="ZEG_01.flt"></Model>
|
|
<Coord Z="2.250" Y="-0.100" X="0.100"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_1</Name>
|
|
<SubId ID="15001"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="2.500" X="-1.070"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_2</Name>
|
|
<SubId ID="15002"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="6.000" X="-1.070"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_3</Name>
|
|
<SubId ID="15003"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="9.500" X="-1.070"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_4</Name>
|
|
<SubId ID="15004"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="13.070" X="1.500"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_5</Name>
|
|
<SubId ID="15005"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="9.524" X="4.266"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_6</Name>
|
|
<SubId ID="15006"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="6.024" X="4.266"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_7</Name>
|
|
<SubId ID="15007"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="2.524" X="4.266"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_8</Name>
|
|
<SubId ID="15008"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="-1.046" X="1.696"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>BDI_P_1</Name>
|
|
<SubId ID="27001"></SubId>
|
|
<Model NAME="BDI.flt"></Model>
|
|
<Coord Z="3.129" Y="6.675" X="1.124"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>BDI_P_2</Name>
|
|
<SubId ID="27002"></SubId>
|
|
<Model NAME="BDI.flt"></Model>
|
|
<Coord Z="0.530" Y="6.617" X="1.171"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Header>
|
|
</STREIF> |