Files
qt6-migration-pipeline/external/BuildingModels/StaticMeshes/bldg_1275.flt.xml
T
2026-10-23 16:13:31 +00:00

522 lines
27 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Mon Nov 29 11:29:50 2021 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_1275</Name>
<ModelId Id="1275"></ModelId>
<BBox_Min Z="-0.200" Y="-1.140" X="-13.140"></BBox_Min>
<BBox_Max Z="6.683" Y="4.336" X="1.116"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.000" X="-12.024"></BBox_Min>
<BBox_Max Z="0.000" Y="3.196" X="0.000"></BBox_Max>
<Polygon>
<Name>p2429</Name>
<Vertex>
<Name>p2429/V1</Name>
<Coord X="-12.024" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2429/V2</Name>
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2429/V3</Name>
<Coord X="0.000" Y="3.196" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2429/V4</Name>
<Coord X="-12.024" Y="3.196" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.200" Y="0.000" X="-6.961"></BBox_Min>
<BBox_Max Z="3.805" Y="3.196" X="0.161"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="-0.000" Y="0.180" X="-6.961"></BBox_Min>
<BBox_Max Z="0.000" Y="3.016" X="-0.140"></BBox_Max>
<Polygon>
<Name>p2477</Name>
<Vertex>
<Name>p2477/V1</Name>
<Coord X="-6.961" Y="2.693" Z="-0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2477/V2</Name>
<Coord X="-6.961" Y="1.683" Z="-0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2477/V3</Name>
<Coord X="-6.781" Y="1.683" Z="-0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2477/V4</Name>
<Coord X="-6.781" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2477/V5</Name>
<Coord X="-0.180" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2477/V6</Name>
<Coord X="-0.180" Y="1.486" Z="-0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2477/V7</Name>
<Coord X="-0.140" Y="1.486" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2477/V8</Name>
<Coord X="-0.140" Y="2.614" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2477/V9</Name>
<Coord X="-0.180" Y="2.614" Z="-0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2477/V10</Name>
<Coord X="-0.180" Y="3.016" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2477/V11</Name>
<Coord X="-6.781" Y="3.016" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2477/V12</Name>
<Coord X="-6.781" Y="2.693" Z="-0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>subroom_1</Name>
<BBox_Min Z="-0.000" Y="0.180" X="-5.677"></BBox_Min>
<BBox_Max Z="2.680" Y="1.192" X="-1.490"></BBox_Max>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0005</Name>
<SubId ID="11005"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.899" Y="-0.091" X="-0.699"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0008</Name>
<SubId ID="11008"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.521" Y="1.225" X="0.125"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.305" Y="2.857" X="-6.781"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.598" X="-3.481"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_102</Name>
<SubId ID="2102"></SubId>
<Group>
<Name>undest_room_102</Name>
<BBox_Min Z="-0.200" Y="-0.083" X="-12.178"></BBox_Min>
<BBox_Max Z="2.680" Y="3.196" X="-6.781"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="-0.000" Y="0.180" X="-11.878"></BBox_Min>
<BBox_Max Z="0.000" Y="3.016" X="-6.961"></BBox_Max>
<Polygon>
<Name>p2478</Name>
<Vertex>
<Name>p2478/V1</Name>
<Coord X="-11.844" Y="3.016" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2478/V2</Name>
<Coord X="-11.844" Y="2.634" Z="-0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2478/V3</Name>
<Coord X="-11.878" Y="2.634" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2478/V4</Name>
<Coord X="-11.878" Y="1.491" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2478/V5</Name>
<Coord X="-11.844" Y="1.491" Z="-0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2478/V6</Name>
<Coord X="-11.844" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2478/V7</Name>
<Coord X="-6.961" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2478/V8</Name>
<Coord X="-6.961" Y="3.016" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0004</Name>
<SubId ID="11004"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.101" Y="-0.166" X="-8.518"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0003</Name>
<SubId ID="11003"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.115" Y="-0.165" X="-11.036"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.569" Y="1.194" X="-12.123999999999999"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_2</Name>
<SubId ID="14002"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.305" Y="0.448" X="-6.961"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.598" X="-9.403"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=2.68</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.480" Y="0.000" X="-6.961"></BBox_Min>
<BBox_Max Z="5.561" Y="3.196" X="0.370"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.680" Y="0.180" X="-6.961"></BBox_Min>
<BBox_Max Z="2.680" Y="3.016" X="-0.180"></BBox_Max>
<Polygon>
<Name>p2434</Name>
<Vertex>
<Name>p2434/V1</Name>
<Coord X="-6.781" Y="3.016" Z="2.680"></Coord>
</Vertex>
<Vertex>
<Name>p2434/V2</Name>
<Coord X="-6.781" Y="2.693" Z="2.680"></Coord>
</Vertex>
<Vertex>
<Name>p2434/V3</Name>
<Coord X="-6.961" Y="2.693" Z="2.680"></Coord>
</Vertex>
<Vertex>
<Name>p2434/V4</Name>
<Coord X="-6.961" Y="1.683" Z="2.680"></Coord>
</Vertex>
<Vertex>
<Name>p2434/V5</Name>
<Coord X="-6.781" Y="1.683" Z="2.680"></Coord>
</Vertex>
<Vertex>
<Name>p2434/V6</Name>
<Coord X="-6.781" Y="0.180" Z="2.680"></Coord>
</Vertex>
<Vertex>
<Name>p2434/V7</Name>
<Coord X="-0.180" Y="0.180" Z="2.680"></Coord>
</Vertex>
<Vertex>
<Name>p2434/V8</Name>
<Coord X="-0.180" Y="3.016" Z="2.680"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>subroom_2</Name>
<BBox_Min Z="2.680" Y="0.180" X="-1.477"></BBox_Min>
<BBox_Max Z="2.680" Y="3.016" X="-0.180"></BBox_Max>
</Group>
<Group>
<Name>subroom_3</Name>
<BBox_Min Z="2.680" Y="1.302" X="-5.677"></BBox_Min>
<BBox_Max Z="2.680" Y="3.016" X="-1.477"></BBox_Max>
</Group>
<Group>
<Name>subroom_4</Name>
<BBox_Min Z="2.680" Y="0.180" X="-6.781"></BBox_Min>
<BBox_Max Z="2.680" Y="3.016" X="-5.677"></BBox_Max>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0009</Name>
<SubId ID="11009"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.512" Y="2.057" X="0.123"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_3</Name>
<SubId ID="14003"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="5.134" Y="0.377" X="-6.781"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_3</Name>
<SubId ID="16003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="2.980" Y="1.598" X="-3.481"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_202</Name>
<SubId ID="2202"></SubId>
<Group>
<Name>undest_room_202</Name>
<BBox_Min Z="2.480" Y="0.000" X="-12.387"></BBox_Min>
<BBox_Max Z="5.538" Y="3.196" X="-6.775"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.680" Y="0.180" X="-11.844"></BBox_Min>
<BBox_Max Z="2.680" Y="3.016" X="-6.961"></BBox_Max>
<Polygon>
<Name>p2433</Name>
<Vertex>
<Name>p2433/V1</Name>
<Coord X="-11.844" Y="3.016" Z="2.680"></Coord>
</Vertex>
<Vertex>
<Name>p2433/V2</Name>
<Coord X="-11.844" Y="0.180" Z="2.680"></Coord>
</Vertex>
<Vertex>
<Name>p2433/V3</Name>
<Coord X="-6.961" Y="0.180" Z="2.680"></Coord>
</Vertex>
<Vertex>
<Name>p2433/V4</Name>
<Coord X="-6.961" Y="3.016" Z="2.680"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0006</Name>
<SubId ID="11006"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.461" Y="-0.096" X="-10.778"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0007</Name>
<SubId ID="11007"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.473" Y="-0.098" X="-8.245"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="5.033" Y="1.664" X="-12.135"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_4</Name>
<SubId ID="14004"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="5.144" Y="2.810" X="-11.844"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_4</Name>
<SubId ID="16004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="2.980" Y="1.598" X="-9.403"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_3</Name>
<Comment>base_height=5.5</Comment>
<Switch>
<Name>SW_room_301</Name>
<SubId ID="2301"></SubId>
<Group>
<Name>undest_room_301</Name>
<BBox_Min Z="5.183" Y="0.000" X="-12.400"></BBox_Min>
<BBox_Max Z="6.683" Y="3.196" X="0.383"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="5.475" Y="0.180" X="-11.844"></BBox_Min>
<BBox_Max Z="5.475" Y="3.016" X="-0.180"></BBox_Max>
<Polygon>
<Name>p2468</Name>
<Vertex>
<Name>p2468/V1</Name>
<Coord X="-0.180" Y="0.180" Z="5.475"></Coord>
</Vertex>
<Vertex>
<Name>p2468/V2</Name>
<Coord X="-0.180" Y="3.016" Z="5.475"></Coord>
</Vertex>
<Vertex>
<Name>p2468/V3</Name>
<Coord X="-11.844" Y="3.016" Z="5.475"></Coord>
</Vertex>
<Vertex>
<Name>p2468/V4</Name>
<Coord X="-11.844" Y="0.180" Z="5.475"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>subroom_5</Name>
<BBox_Min Z="5.394" Y="0.180" X="-6.009"></BBox_Min>
<BBox_Max Z="5.560" Y="3.016" X="-0.180"></BBox_Max>
</Group>
<Group>
<Name>subroom_6</Name>
<BBox_Min Z="5.538" Y="0.180" X="-6.781"></BBox_Min>
<BBox_Max Z="5.560" Y="3.016" X="-6.009"></BBox_Max>
</Group>
<Group>
<Name>subroom_7</Name>
<BBox_Min Z="5.394" Y="0.180" X="-11.844"></BBox_Min>
<BBox_Max Z="5.538" Y="3.016" X="-6.781"></BBox_Max>
</Group>
<External_Reference>
<Name>IPS_IN_AP_5</Name>
<SubId ID="16005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="5.777" Y="1.598" X="-3.094"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_6</Name>
<SubId ID="16006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="5.777" Y="1.598" X="-8.927"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="2.430" Y="3.096" X="0.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.070" X="-2.500"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.070" X="-6.000"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.070" X="-9.500"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="1.500" X="-13.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_5</Name>
<SubId ID="15005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="4.266" X="-9.524"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_6</Name>
<SubId ID="15006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="4.266" X="-6.024"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_7</Name>
<SubId ID="15007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="4.266" X="-2.524"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_8</Name>
<SubId ID="15008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="1.696" X="1.046"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.747" Y="0.821" X="-6.616"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_2</Name>
<SubId ID="27002"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="3.425" Y="0.697" X="-0.358"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>