Files
qt6-migration-pipeline/external/BuildingModels/StaticMeshes/bldg_3135.flt.xml
T
2026-10-23 16:13:31 +00:00

419 lines
21 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Tue Dec 07 09:10:30 2021 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_3135</Name>
<ModelId Id="1135"></ModelId>
<BBox_Min Z="-0.300" Y="-1.070" X="-1.070"></BBox_Min>
<BBox_Max Z="3.969" Y="7.070" X="13.070"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.000" X="0.000"></BBox_Min>
<BBox_Max Z="0.000" Y="6.000" X="12.000"></BBox_Max>
<Polygon>
<Name>p3059</Name>
<Vertex>
<Name>p3059/V1</Name>
<Coord X="12.000" Y="6.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3059/V2</Name>
<Coord X="0.000" Y="6.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3059/V3</Name>
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3059/V4</Name>
<Coord X="12.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0.00</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.300" Y="-0.354" X="-0.075"></BBox_Min>
<BBox_Max Z="3.178" Y="3.501" X="5.256"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="0.000" Y="3.321" X="5.076"></BBox_Max>
<Polygon>
<Name>p3055</Name>
<Vertex>
<Name>p3055/V1</Name>
<Coord X="5.076" Y="3.321" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3055/V2</Name>
<Coord X="0.180" Y="3.321" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3055/V3</Name>
<Coord X="0.180" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3055/V4</Name>
<Coord X="5.076" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0009</Name>
<SubId ID="11009"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.059" Y="1.629" X="-0.173"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0003</Name>
<SubId ID="11003"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.05" Y="-0.198" X="2.535"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.764" X="2.619"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.127" Y="1.153" X="5.076"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_102</Name>
<SubId ID="2102"></SubId>
<Group>
<Name>undest_room_102</Name>
<BBox_Min Z="-0.300" Y="3.321" X="0.000"></BBox_Min>
<BBox_Max Z="2.874" Y="6.075" X="6.919"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="3.501" X="0.180"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="6.739"></BBox_Max>
<Polygon>
<Name>p3056</Name>
<Vertex>
<Name>p3056/V1</Name>
<Coord X="6.739" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3056/V2</Name>
<Coord X="0.180" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3056/V3</Name>
<Coord X="0.180" Y="3.501" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3056/V4</Name>
<Coord X="6.739" Y="3.501" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.041" Y="6.188000000000001" X="3.74"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0008</Name>
<SubId ID="11008"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.292" Y="4.529" X="-0.104"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.718" X="3.361"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_2</Name>
<SubId ID="14002"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.127" Y="4.600" X="6.739"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_103</Name>
<SubId ID="2103"></SubId>
<Group>
<Name>undest_room_103</Name>
<BBox_Min Z="-0.300" Y="3.321" X="6.739"></BBox_Min>
<BBox_Max Z="2.874" Y="6.000" X="12.075"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="3.501" X="6.919"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="11.820"></BBox_Max>
<Polygon>
<Name>p3057</Name>
<Vertex>
<Name>p3057/V1</Name>
<Coord X="6.919" Y="3.501" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3057/V2</Name>
<Coord X="11.820" Y="3.501" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3057/V3</Name>
<Coord X="11.820" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3057/V4</Name>
<Coord X="6.919" Y="5.820" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.288" Y="6.112" X="9.716"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0007</Name>
<SubId ID="11007"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.044" Y="4.37" X="12.190999999999999"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_3</Name>
<SubId ID="16003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.687" X="9.370"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_3</Name>
<SubId ID="14003"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.127" Y="4.600" X="8.036"></Coord>
<Dir Z="0.000" Y="0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_104</Name>
<SubId ID="2104"></SubId>
<Group>
<Name>undest_room_104</Name>
<BBox_Min Z="-0.300" Y="-0.354" X="5.076"></BBox_Min>
<BBox_Max Z="2.802" Y="3.501" X="12.000"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="5.256"></BBox_Min>
<BBox_Max Z="0.000" Y="3.321" X="11.820"></BBox_Max>
<Polygon>
<Name>p3058</Name>
<Vertex>
<Name>p3058/V1</Name>
<Coord X="11.820" Y="3.321" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3058/V2</Name>
<Coord X="5.256" Y="3.321" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3058/V3</Name>
<Coord X="5.256" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3058/V4</Name>
<Coord X="11.820" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0004</Name>
<SubId ID="11004"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.284" Y="-0.127" X="6.399"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0005</Name>
<SubId ID="11005"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.054" Y="-0.212" X="9.064"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0006</Name>
<SubId ID="11006"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.943" Y="1.244" X="12.116999999999999"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_4</Name>
<SubId ID="16004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.809" X="8.541"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_4</Name>
<SubId ID="14004"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.127" Y="2.229" X="5.256"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=2.7</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.494" Y="-0.384" X="0.000"></BBox_Min>
<BBox_Max Z="3.969" Y="6.000" X="12.000"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="0.000" X="0.180"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="11.820"></BBox_Max>
<Polygon>
<Name>p2657</Name>
<Vertex>
<Name>p2657/V1</Name>
<Coord X="11.820" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p2657/V2</Name>
<Coord X="0.180" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p2657/V3</Name>
<Coord X="0.180" Y="0.000" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p2657/V4</Name>
<Coord X="11.820" Y="0.000" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>IPS_IN_AP_5</Name>
<SubId ID="16005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.010" Y="3.110" X="6.148"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="2.250" Y="-0.100" X="0.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="5.000" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.000" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="2.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="6.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_5</Name>
<SubId ID="15005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="9.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_6</Name>
<SubId ID="15006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.000" X="13.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_7</Name>
<SubId ID="15007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="5.000" X="13.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_8</Name>
<SubId ID="15008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.000" X="9.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_9</Name>
<SubId ID="15009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.000" X="6.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_10</Name>
<SubId ID="15010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.000" X="2.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.550" Y="3.221" X="6.345"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>