Files
qt6-migration-pipeline/external/BuildingModels/StaticMeshes/bldg_3156.flt.xml
T
2026-10-23 16:13:31 +00:00

775 lines
40 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Mon Dec 20 17:30:53 2021 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_3156</Name>
<ModelId Id="1156"></ModelId>
<BBox_Min Z="-0.300" Y="-1.140" X="-1.140"></BBox_Min>
<BBox_Max Z="8.663" Y="7.122" X="13.140"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.000" X="0.000"></BBox_Min>
<BBox_Max Z="0.000" Y="6.000" X="12.000"></BBox_Max>
<Polygon>
<Name>p9751</Name>
<Vertex>
<Name>p9751/V1</Name>
<Coord X="12.000" Y="6.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p9751/V2</Name>
<Coord X="0.000" Y="6.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p9751/V3</Name>
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p9751/V4</Name>
<Coord X="12.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0.00</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.300" Y="-0.151" X="-0.075"></BBox_Min>
<BBox_Max Z="2.700" Y="6.156" X="3.356"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="3.176"></BBox_Max>
<Polygon>
<Name>p9747</Name>
<Vertex>
<Name>p9747/V1</Name>
<Coord X="3.176" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p9747/V2</Name>
<Coord X="0.180" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p9747/V3</Name>
<Coord X="0.180" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p9747/V4</Name>
<Coord X="3.176" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0015</Name>
<SubId ID="11015"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.987" Y="6.184" X="2.632"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.297" Y="-0.119" X="1.722"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0021</Name>
<SubId ID="11021"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.006" Y="3.818" X="-0.156"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.063" X="1.671"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.266" Y="5.820" X="0.759"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_102</Name>
<SubId ID="2102"></SubId>
<Group>
<Name>undest_room_102</Name>
<BBox_Min Z="-0.300" Y="2.059" X="3.176"></BBox_Min>
<BBox_Max Z="2.700" Y="6.075" X="5.729"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="2.239" X="3.356"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="5.427"></BBox_Max>
<Polygon>
<Name>p9748</Name>
<Vertex>
<Name>p9748/V1</Name>
<Coord X="5.427" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p9748/V2</Name>
<Coord X="3.356" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p9748/V3</Name>
<Coord X="3.356" Y="2.239" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p9748/V4</Name>
<Coord X="5.427" Y="2.239" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0014</Name>
<SubId ID="11014"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.004" Y="6.187" X="5.515"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.974" X="4.403"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_2</Name>
<SubId ID="14002"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.266" Y="5.820" X="3.747"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_103</Name>
<SubId ID="2103"></SubId>
<Group>
<Name>undest_room_103</Name>
<BBox_Min Z="-0.300" Y="-0.075" X="3.048"></BBox_Min>
<BBox_Max Z="3.790" Y="6.000" X="8.307"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="3.356"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="8.127"></BBox_Max>
<Polygon>
<Name>p9749</Name>
<Vertex>
<Name>p9749/V1</Name>
<Coord X="8.127" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p9749/V2</Name>
<Coord X="8.127" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p9749/V3</Name>
<Coord X="5.607" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p9749/V4</Name>
<Coord X="5.607" Y="1.858" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p9749/V5</Name>
<Coord X="5.427" Y="1.858" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p9749/V6</Name>
<Coord X="5.427" Y="2.059" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p9749/V7</Name>
<Coord X="3.356" Y="2.059" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p9749/V8</Name>
<Coord X="3.356" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0013</Name>
<SubId ID="11013"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.238" Y="6.111000000000001" X="6.921"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0003</Name>
<SubId ID="11003"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.334" Y="-0.124" X="6.56"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.026" Y="-0.196" X="3.42"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_3</Name>
<SubId ID="16003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.157" X="6.164"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_3</Name>
<SubId ID="14003"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.266" Y="1.739" X="3.356"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_104</Name>
<SubId ID="2104"></SubId>
<Group>
<Name>undest_room_104</Name>
<BBox_Min Z="-0.300" Y="-0.151" X="8.127"></BBox_Min>
<BBox_Max Z="2.700" Y="6.156" X="12.075"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="8.307"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="11.820"></BBox_Max>
<Polygon>
<Name>p9750</Name>
<Vertex>
<Name>p9750/V1</Name>
<Coord X="11.820" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p9750/V2</Name>
<Coord X="8.307" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p9750/V3</Name>
<Coord X="8.307" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p9750/V4</Name>
<Coord X="11.820" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0012</Name>
<SubId ID="11012"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.227" Y="6.115" X="10.045"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0010</Name>
<SubId ID="11010"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.885" Y="4.356" X="12.110999999999999"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0009</Name>
<SubId ID="11009"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.035" Y="1.718" X="12.192"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0004</Name>
<SubId ID="11004"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.04" Y="-0.20400000000000001" X="9.247"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_4</Name>
<SubId ID="16004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.040" X="10.038"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_4</Name>
<SubId ID="14004"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.266" Y="5.820" X="11.287"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=2.7</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.500" Y="-0.151" X="0.000"></BBox_Min>
<BBox_Max Z="5.400" Y="6.156" X="3.356"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="3.176"></BBox_Max>
<Polygon>
<Name>p8733</Name>
<Vertex>
<Name>p8733/V1</Name>
<Coord X="3.176" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p8733/V2</Name>
<Coord X="0.180" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p8733/V3</Name>
<Coord X="0.180" Y="0.180" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p8733/V4</Name>
<Coord X="3.176" Y="0.180" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0019</Name>
<SubId ID="11019"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.445" Y="6.1080000000000005" X="1.847"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0005</Name>
<SubId ID="11005"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.414" Y="-0.117" X="1.734"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0022</Name>
<SubId ID="11022"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.458" Y="3.001" X="-0.11801234567800001"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_5</Name>
<SubId ID="16005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.074" Y="3.059" X="1.750"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_5</Name>
<SubId ID="14005"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.949" Y="5.820" X="0.759"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_202</Name>
<SubId ID="2202"></SubId>
<Group>
<Name>undest_room_202</Name>
<BBox_Min Z="2.500" Y="2.059" X="3.176"></BBox_Min>
<BBox_Max Z="5.400" Y="6.000" X="5.607"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="2.239" X="3.356"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="5.427"></BBox_Max>
<Polygon>
<Name>p8734</Name>
<Vertex>
<Name>p8734/V1</Name>
<Coord X="5.427" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p8734/V2</Name>
<Coord X="3.356" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p8734/V3</Name>
<Coord X="3.356" Y="2.239" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p8734/V4</Name>
<Coord X="5.427" Y="2.239" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0018</Name>
<SubId ID="11018"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.431" Y="6.109" X="4.458"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_6</Name>
<SubId ID="16006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.074" Y="3.939" X="4.484"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_6</Name>
<SubId ID="14006"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.949" Y="5.820" X="5.172"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_203</Name>
<SubId ID="2203"></SubId>
<Group>
<Name>undest_room_203</Name>
<BBox_Min Z="2.500" Y="0.000" X="3.176"></BBox_Min>
<BBox_Max Z="6.490" Y="6.000" X="8.307"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="0.180" X="3.356"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="8.127"></BBox_Max>
<Polygon>
<Name>p8735</Name>
<Vertex>
<Name>p8735/V1</Name>
<Coord X="8.127" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p8735/V2</Name>
<Coord X="5.607" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p8735/V3</Name>
<Coord X="5.607" Y="1.858" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p8735/V4</Name>
<Coord X="5.427" Y="1.858" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p8735/V5</Name>
<Coord X="5.427" Y="2.059" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p8735/V6</Name>
<Coord X="3.356" Y="2.059" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p8735/V7</Name>
<Coord X="3.356" Y="0.180" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p8735/V8</Name>
<Coord X="8.127" Y="0.180" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0017</Name>
<SubId ID="11017"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.487" Y="6.111000000000001" X="6.866"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0006</Name>
<SubId ID="11006"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.504" Y="-0.119" X="4.121"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_7</Name>
<SubId ID="16007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.074" Y="1.071" X="5.751"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_7</Name>
<SubId ID="14007"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.988" Y="5.820" X="7.641"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_204</Name>
<SubId ID="2204"></SubId>
<Group>
<Name>undest_room_204</Name>
<BBox_Min Z="2.500" Y="-0.151" X="8.127"></BBox_Min>
<BBox_Max Z="5.400" Y="6.156" X="12.000"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="0.180" X="8.307"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="11.820"></BBox_Max>
<Polygon>
<Name>p8796</Name>
<Vertex>
<Name>p8796/V1</Name>
<Coord X="11.820" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p8796/V2</Name>
<Coord X="8.307" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p8796/V3</Name>
<Coord X="8.307" Y="0.180" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p8796/V4</Name>
<Coord X="11.820" Y="0.180" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0016</Name>
<SubId ID="11016"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.454" Y="6.1160000000000005" X="10.076"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0011</Name>
<SubId ID="11011"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.502" Y="2.515" X="12.12"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0007</Name>
<SubId ID="11007"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.511" Y="-0.123" X="10.042"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_8</Name>
<SubId ID="16008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.074" Y="2.945" X="10.144"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_8</Name>
<SubId ID="14008"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.949" Y="5.820" X="11.287"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_3</Name>
<Comment>base_height=5.4</Comment>
<Switch>
<Name>SW_room_301</Name>
<SubId ID="2301"></SubId>
<Group>
<Name>undest_room_301</Name>
<BBox_Min Z="5.200" Y="-0.737" X="-0.225"></BBox_Min>
<BBox_Max Z="8.663" Y="6.741" X="12.225"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="5.400" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="5.400" Y="5.820" X="11.820"></BBox_Max>
<Polygon>
<Name>p8297</Name>
<Vertex>
<Name>p8297/V1</Name>
<Coord X="11.820" Y="5.820" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p8297/V2</Name>
<Coord X="0.180" Y="5.820" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p8297/V3</Name>
<Coord X="0.180" Y="0.180" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p8297/V4</Name>
<Coord X="11.820" Y="0.180" Z="5.400"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0020</Name>
<SubId ID="11020"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="8.04526" Y="5.252" X="4.036"></Coord>
<Dir Z="0.866" Y="0.500" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0008</Name>
<SubId ID="11008"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="8.07826" Y="0.74" X="7.985"></Coord>
<Dir Z="0.866" Y="-0.500" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_9</Name>
<SubId ID="16009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="5.774" Y="2.937" X="10.114"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_10</Name>
<SubId ID="16010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="5.774" Y="3.007" X="2.919"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_9</Name>
<SubId ID="14009"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="5.671" Y="5.820" X="7.641"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_10</Name>
<SubId ID="14010"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="7.490" Y="3.002" X="0.180"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_4</Name>
<Comment>base_height=8.66</Comment>
<Switch>
<Name>SW_room_401</Name>
<SubId ID="2401"></SubId>
<Group>
<Name>undest_room_401</Name>
<BBox_Min Z="6.407" Y="-0.737" X="-0.225"></BBox_Min>
<BBox_Max Z="8.663" Y="6.741" X="12.225"></BBox_Max>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="2.250" Y="-0.100" X="0.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="7.052" X="1.477"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="7.052" X="5.977"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="7.052" X="10.477"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="4.500" X="13.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_5</Name>
<SubId ID="15005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="1.500" X="13.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_6</Name>
<SubId ID="15006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.070" X="10.500"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_7</Name>
<SubId ID="15007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.070" X="6.000"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_8</Name>
<SubId ID="15008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.070" X="1.500"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_9</Name>
<SubId ID="15009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="1.500" X="-1.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_10</Name>
<SubId ID="15010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="4.500" X="-1.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.494" Y="2.659" X="5.329"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_2</Name>
<SubId ID="27002"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="3.175" Y="2.652" X="5.323"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>