Files
qt6-migration-pipeline/external/BuildingModels/StaticMeshes/bldg_3219.flt.xml
T
2026-10-23 16:13:31 +00:00

721 lines
37 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Tue Jan 11 14:53:51 2022 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_3219</Name>
<ModelId Id="1219"></ModelId>
<BBox_Min Z="-0.300" Y="-1.070" X="-1.070"></BBox_Min>
<BBox_Max Z="6.762" Y="9.570" X="7.070"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.000" X="0.000"></BBox_Min>
<BBox_Max Z="0.000" Y="8.777" X="6.000"></BBox_Max>
<Polygon>
<Name>p6830</Name>
<Vertex>
<Name>p6830/V1</Name>
<Coord X="1.032" Y="8.777" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6830/V2</Name>
<Coord X="1.032" Y="6.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6830/V3</Name>
<Coord X="0.090" Y="6.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6830/V4</Name>
<Coord X="0.090" Y="2.950" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6830/V5</Name>
<Coord X="0.000" Y="2.950" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6830/V6</Name>
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6830/V7</Name>
<Coord X="6.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6830/V8</Name>
<Coord X="6.000" Y="8.777" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0.00</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.300" Y="0.000" X="-0.075"></BBox_Min>
<BBox_Max Z="2.700" Y="2.425" X="2.187"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="0.000" Y="2.245" X="2.007"></BBox_Max>
<Polygon>
<Name>p6825</Name>
<Vertex>
<Name>p6825/V1</Name>
<Coord X="2.007" Y="2.245" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6825/V2</Name>
<Coord X="0.180" Y="2.245" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6825/V3</Name>
<Coord X="0.180" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6825/V4</Name>
<Coord X="2.007" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0005</Name>
<SubId ID="11005"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.308" Y="-0.112" X="0.744"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0011</Name>
<SubId ID="11011"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.05" Y="1.482" X="-0.173"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.244" X="1.114"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.196" Y="2.245" X="1.583"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_102</Name>
<SubId ID="2102"></SubId>
<Group>
<Name>undest_room_102</Name>
<BBox_Min Z="-0.300" Y="2.245" X="0.000"></BBox_Min>
<BBox_Max Z="2.700" Y="6.075" X="3.099"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="2.425" X="0.180"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="2.919"></BBox_Max>
<Polygon>
<Name>p6826</Name>
<Vertex>
<Name>p6826/V1</Name>
<Coord X="0.180" Y="2.425" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6826/V2</Name>
<Coord X="2.919" Y="2.425" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6826/V3</Name>
<Coord X="2.919" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6826/V4</Name>
<Coord X="0.180" Y="5.820" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0008</Name>
<SubId ID="11008"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.148" Y="6.166" X="1.623"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_2</Name>
<SubId ID="14002"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.290" Y="3.096" X="0.180"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.178" X="1.615"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_103</Name>
<SubId ID="2103"></SubId>
<Group>
<Name>undest_room_103</Name>
<BBox_Min Z="-0.300" Y="2.245" X="2.919"></BBox_Min>
<BBox_Max Z="2.700" Y="6.000" X="6.075"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="2.425" X="3.099"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="5.820"></BBox_Max>
<Polygon>
<Name>p6827</Name>
<Vertex>
<Name>p6827/V1</Name>
<Coord X="5.820" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6827/V2</Name>
<Coord X="3.099" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6827/V3</Name>
<Coord X="3.099" Y="2.425" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6827/V4</Name>
<Coord X="5.820" Y="2.425" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.145" Y="3.704" X="6.187"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_6</Name>
<SubId ID="14006"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.290" Y="5.820" X="5.499"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_3</Name>
<SubId ID="16003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.195" X="4.449"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_104</Name>
<SubId ID="2104"></SubId>
<Group>
<Name>undest_room_104</Name>
<BBox_Min Z="-0.300" Y="-0.143" X="1.937"></BBox_Min>
<BBox_Max Z="2.700" Y="2.425" X="6.000"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="2.187"></BBox_Min>
<BBox_Max Z="0.000" Y="2.245" X="5.820"></BBox_Max>
<Polygon>
<Name>p6828</Name>
<Vertex>
<Name>p6828/V1</Name>
<Coord X="5.820" Y="2.245" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6828/V2</Name>
<Coord X="2.187" Y="2.245" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6828/V3</Name>
<Coord X="2.187" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6828/V4</Name>
<Coord X="5.820" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0007</Name>
<SubId ID="11007"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.88" Y="-0.118" X="4.784"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0006</Name>
<SubId ID="11006"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.034" Y="-0.182" X="2.714"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.409" Y="1.152" X="6.105"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_4</Name>
<SubId ID="16004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.257" X="3.923"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_3</Name>
<SubId ID="14003"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.196" Y="1.857" X="2.187"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_105</Name>
<SubId ID="2105"></SubId>
<Group>
<Name>undest_room_105</Name>
<BBox_Min Z="0.000" Y="5.820" X="0.164"></BBox_Min>
<BBox_Max Z="3.790" Y="8.777" X="6.035"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="6.000" X="1.032"></BBox_Min>
<BBox_Max Z="0.000" Y="8.777" X="6.000"></BBox_Max>
<Polygon>
<Name>p6146_1</Name>
<Vertex>
<Name>p6146_1/V1</Name>
<Coord X="6.000" Y="8.777" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6146_1/V2</Name>
<Coord X="1.032" Y="8.777" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6146_1/V3</Name>
<Coord X="1.032" Y="6.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p6146_1/V4</Name>
<Coord X="6.000" Y="6.000" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>IPS_IN_AP_5</Name>
<SubId ID="16005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="6.726" X="1.950"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=2.7</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.500" Y="-0.345" X="0.000"></BBox_Min>
<BBox_Max Z="5.550" Y="2.425" X="6.000"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="2.700" Y="2.245" X="5.820"></BBox_Max>
<Polygon>
<Name>p6149</Name>
<Vertex>
<Name>p6149/V1</Name>
<Coord X="5.820" Y="2.245" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6149/V2</Name>
<Coord X="0.180" Y="2.245" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6149/V3</Name>
<Coord X="0.180" Y="0.180" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6149/V4</Name>
<Coord X="5.820" Y="0.180" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0003</Name>
<SubId ID="11003"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.582" Y="1.194" X="6.105"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0013</Name>
<SubId ID="11013"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.504" Y="1.203" X="-0.096"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_5</Name>
<SubId ID="14005"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="5.046" Y="0.455" X="0.180"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_6</Name>
<SubId ID="16006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.074" Y="1.261" X="2.975"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_202</Name>
<SubId ID="2202"></SubId>
<Group>
<Name>undest_room_202</Name>
<BBox_Min Z="2.500" Y="2.245" X="0.000"></BBox_Min>
<BBox_Max Z="5.669" Y="6.000" X="3.099"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="2.425" X="0.180"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="2.919"></BBox_Max>
<Polygon>
<Name>p6148</Name>
<Vertex>
<Name>p6148/V1</Name>
<Coord X="2.919" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6148/V2</Name>
<Coord X="0.180" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6148/V3</Name>
<Coord X="0.180" Y="2.425" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6148/V4</Name>
<Coord X="2.919" Y="2.425" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0012</Name>
<SubId ID="11012"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="5.2" Y="4.347" X="-0.097"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0010</Name>
<SubId ID="11010"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="5.127" Y="6.090000000000001" X="1.39"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_7</Name>
<SubId ID="14007"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="5.046" Y="2.425" X="0.654"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_7</Name>
<SubId ID="16007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.074" Y="4.052" X="1.641"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_203</Name>
<SubId ID="2203"></SubId>
<Group>
<Name>undest_room_203</Name>
<BBox_Min Z="2.500" Y="2.245" X="2.919"></BBox_Min>
<BBox_Max Z="5.669" Y="6.000" X="6.000"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="2.425" X="3.099"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="5.820"></BBox_Max>
<Polygon>
<Name>p6147</Name>
<Vertex>
<Name>p6147/V1</Name>
<Coord X="5.820" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6147/V2</Name>
<Coord X="3.099" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6147/V3</Name>
<Coord X="3.099" Y="2.425" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6147/V4</Name>
<Coord X="5.820" Y="2.425" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0009</Name>
<SubId ID="11009"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.802" Y="6.112" X="4.296"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_4</Name>
<SubId ID="14004"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.896" Y="5.820" X="5.447"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_8</Name>
<SubId ID="16008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.074" Y="4.082" X="4.452"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_204</Name>
<SubId ID="2204"></SubId>
<Group>
<Name>undest_room_204</Name>
<BBox_Min Z="2.500" Y="5.820" X="0.180"></BBox_Min>
<BBox_Max Z="6.762" Y="8.777" X="6.035"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="6.000" X="1.032"></BBox_Min>
<BBox_Max Z="2.700" Y="8.777" X="6.000"></BBox_Max>
<Polygon>
<Name>p6146</Name>
<Vertex>
<Name>p6146/V1</Name>
<Coord X="6.000" Y="8.777" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6146/V2</Name>
<Coord X="1.032" Y="8.777" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6146/V3</Name>
<Coord X="1.032" Y="6.000" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p6146/V4</Name>
<Coord X="6.000" Y="6.000" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>IPS_IN_AP_9</Name>
<SubId ID="16009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.074" Y="7.414" X="1.674"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_3</Name>
<Comment>base_height=5.47</Comment>
<Switch>
<Name>SW_room_301</Name>
<SubId ID="2301"></SubId>
<Group>
<Name>undest_room_301</Name>
<BBox_Min Z="5.263" Y="-0.375" X="0.000"></BBox_Min>
<BBox_Max Z="6.736" Y="6.000" X="6.000"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="5.470" Y="0.000" X="0.180"></BBox_Min>
<BBox_Max Z="5.470" Y="5.820" X="5.825"></BBox_Max>
<Polygon>
<Name>p5373</Name>
<Vertex>
<Name>p5373/V1</Name>
<Coord X="5.825" Y="5.820" Z="5.470"></Coord>
</Vertex>
<Vertex>
<Name>p5373/V2</Name>
<Coord X="0.180" Y="5.820" Z="5.470"></Coord>
</Vertex>
<Vertex>
<Name>p5373/V3</Name>
<Coord X="0.180" Y="0.000" Z="5.470"></Coord>
</Vertex>
<Vertex>
<Name>p5373/V4</Name>
<Coord X="5.825" Y="0.000" Z="5.470"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>IPS_IN_AP_10</Name>
<SubId ID="16010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="5.924" Y="3.155" X="3.009"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_302</Name>
<SubId ID="2302"></SubId>
<Group>
<Name>undest_room_302</Name>
<BBox_Min Z="5.460" Y="6.000" X="1.032"></BBox_Min>
<BBox_Max Z="6.762" Y="8.777" X="2.380"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="5.660" Y="6.000" X="1.032"></BBox_Min>
<BBox_Max Z="5.660" Y="8.777" X="2.321"></BBox_Max>
<Polygon>
<Name>p5374</Name>
<Vertex>
<Name>p5374/V1</Name>
<Coord X="1.032" Y="6.000" Z="5.660"></Coord>
</Vertex>
<Vertex>
<Name>p5374/V2</Name>
<Coord X="2.321" Y="6.000" Z="5.660"></Coord>
</Vertex>
<Vertex>
<Name>p5374/V3</Name>
<Coord X="2.321" Y="8.777" Z="5.660"></Coord>
</Vertex>
<Vertex>
<Name>p5374/V4</Name>
<Coord X="1.032" Y="8.777" Z="5.660"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>IPS_IN_AP_11</Name>
<SubId ID="16011"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="5.924" Y="7.402" X="1.705"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="2.250" Y="-0.100" X="0.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0004</Name>
<SubId ID="11004"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.6" Y="6.087000000000001" X="4.875"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="1.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="4.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="2.000" X="7.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="5.500" X="7.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_5</Name>
<SubId ID="15005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="9.500" X="4.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_6</Name>
<SubId ID="15006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="9.500" X="1.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_7</Name>
<SubId ID="15007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="5.500" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_8</Name>
<SubId ID="15008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="2.000" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.600" Y="4.244" X="3.199"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_2</Name>
<SubId ID="27002"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="3.388" Y="4.559" X="3.199"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>