Files
qt6-migration-pipeline/external/BuildingModels/StaticMeshes/bldg_3242.flt.xml
T
2026-10-23 16:13:31 +00:00

752 lines
39 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Mon Jan 17 14:10:37 2022 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_3242</Name>
<ModelId Id="1242"></ModelId>
<BBox_Min Z="-0.300" Y="-1.070" X="-1.070"></BBox_Min>
<BBox_Max Z="8.629" Y="7.081" X="13.075"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.000" X="0.000"></BBox_Min>
<BBox_Max Z="0.000" Y="6.011" X="12.005"></BBox_Max>
<Polygon>
<Name>p2131</Name>
<Vertex>
<Name>p2131/V1</Name>
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2131/V2</Name>
<Coord X="12.005" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2131/V3</Name>
<Coord X="12.005" Y="6.011" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2131/V4</Name>
<Coord X="0.000" Y="6.011" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0.00</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.300" Y="-0.000" X="-0.072"></BBox_Min>
<BBox_Max Z="2.690" Y="6.083" X="4.554"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.175" X="0.200"></BBox_Min>
<BBox_Max Z="0.000" Y="5.836" X="4.379"></BBox_Max>
<Polygon>
<Name>p1945</Name>
<Vertex>
<Name>p1945/V1</Name>
<Coord X="0.200" Y="0.175" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1945/V2</Name>
<Coord X="4.379" Y="0.175" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1945/V3</Name>
<Coord X="4.379" Y="5.836" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1945/V4</Name>
<Coord X="0.200" Y="5.836" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0016</Name>
<SubId ID="11016"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.151" Y="6.202" X="2.272"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0012</Name>
<SubId ID="11012"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.022" Y="3.255" X="-0.199"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.349" Y="-0.134" X="2.436"></Coord>
<Dir Z="-0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.006" X="2.290"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.219" Y="5.836" X="0.986"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_102</Name>
<SubId ID="2102"></SubId>
<Group>
<Name>undest_room_102</Name>
<BBox_Min Z="-0.300" Y="-0.072" X="4.379"></BBox_Min>
<BBox_Max Z="3.848" Y="6.011" X="7.840"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.175" X="4.554"></BBox_Min>
<BBox_Max Z="0.000" Y="5.836" X="7.665"></BBox_Max>
<Polygon>
<Name>p1946</Name>
<Vertex>
<Name>p1946/V1</Name>
<Coord X="4.554" Y="5.836" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1946/V2</Name>
<Coord X="4.554" Y="0.175" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1946/V3</Name>
<Coord X="7.665" Y="0.175" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1946/V4</Name>
<Coord X="7.665" Y="1.889" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1946/V5</Name>
<Coord X="7.065" Y="1.889" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1946/V6</Name>
<Coord X="7.065" Y="5.836" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0015</Name>
<SubId ID="11015"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.409" Y="6.1240000000000006" X="5.405"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.03" Y="-0.201" X="5.793"></Coord>
<Dir Z="-0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="1.570" Y="5.209" X="5.810"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_3</Name>
<SubId ID="16003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.032" X="6.109"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_2</Name>
<SubId ID="14002"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="3.281" Y="5.836" X="5.194"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_103</Name>
<SubId ID="2103"></SubId>
<Group>
<Name>undest_room_103</Name>
<BBox_Min Z="-0.300" Y="1.889" X="7.065"></BBox_Min>
<BBox_Max Z="2.690" Y="6.134" X="12.083"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="2.064" X="7.240"></BBox_Min>
<BBox_Max Z="0.000" Y="5.836" X="11.830"></BBox_Max>
<Polygon>
<Name>p1947</Name>
<Vertex>
<Name>p1947/V1</Name>
<Coord X="11.830" Y="5.836" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1947/V2</Name>
<Coord X="7.240" Y="5.836" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1947/V3</Name>
<Coord X="7.240" Y="2.064" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1947/V4</Name>
<Coord X="11.830" Y="2.064" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0014</Name>
<SubId ID="11014"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.429" Y="6.125" X="9.564"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0009</Name>
<SubId ID="11009"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.036" Y="4.035" X="12.190999999999999"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_4</Name>
<SubId ID="16004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.950" X="9.535"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_4</Name>
<SubId ID="14004"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.219" Y="2.598" X="7.240"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_104</Name>
<SubId ID="2104"></SubId>
<Group>
<Name>undest_room_104</Name>
<BBox_Min Z="-0.300" Y="-0.134" X="7.665"></BBox_Min>
<BBox_Max Z="2.690" Y="2.064" X="12.005"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.175" X="7.840"></BBox_Min>
<BBox_Max Z="0.000" Y="1.889" X="11.830"></BBox_Max>
<Polygon>
<Name>p1949</Name>
<Vertex>
<Name>p1949/V1</Name>
<Coord X="11.830" Y="1.889" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1949/V2</Name>
<Coord X="7.840" Y="1.889" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1949/V3</Name>
<Coord X="7.840" Y="0.175" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1949/V4</Name>
<Coord X="11.830" Y="0.175" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0008</Name>
<SubId ID="11008"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.854" Y="1.383" X="12.116999999999999"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0003</Name>
<SubId ID="11003"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.03" Y="-0.20600000000000002" X="9.731"></Coord>
<Dir Z="-0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_5</Name>
<SubId ID="16005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.032" X="9.835"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_3</Name>
<SubId ID="14003"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.219" Y="0.537" X="11.830"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=2.69</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.490" Y="0.000" X="0.000"></BBox_Min>
<BBox_Max Z="5.400" Y="6.011" X="4.554"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.690" Y="0.175" X="0.200"></BBox_Min>
<BBox_Max Z="2.690" Y="5.836" X="4.379"></BBox_Max>
<Polygon>
<Name>p1931</Name>
<Vertex>
<Name>p1931/V1</Name>
<Coord X="4.379" Y="5.836" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p1931/V2</Name>
<Coord X="0.200" Y="5.836" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p1931/V3</Name>
<Coord X="0.200" Y="0.175" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p1931/V4</Name>
<Coord X="4.379" Y="0.175" Z="2.690"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0013</Name>
<SubId ID="11013"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.497" Y="2.99" X="-0.127"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0019</Name>
<SubId ID="11019"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.621" Y="6.123" X="2.042"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0004</Name>
<SubId ID="11004"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.481" Y="-0.125" X="2.238"></Coord>
<Dir Z="-0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_6</Name>
<SubId ID="16006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="2.990" Y="3.006" X="2.290"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_5</Name>
<SubId ID="14005"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.828" Y="0.552" X="0.200"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_202</Name>
<SubId ID="2202"></SubId>
<Group>
<Name>undest_room_202</Name>
<BBox_Min Z="2.490" Y="0.000" X="4.379"></BBox_Min>
<BBox_Max Z="6.538" Y="6.011" X="7.840"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.690" Y="0.175" X="4.554"></BBox_Min>
<BBox_Max Z="2.690" Y="5.836" X="7.665"></BBox_Max>
<Polygon>
<Name>p1932</Name>
<Vertex>
<Name>p1932/V1</Name>
<Coord X="7.065" Y="5.836" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p1932/V2</Name>
<Coord X="4.554" Y="5.836" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p1932/V3</Name>
<Coord X="4.554" Y="0.175" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p1932/V4</Name>
<Coord X="7.665" Y="0.175" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p1932/V5</Name>
<Coord X="7.665" Y="1.889" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p1932/V6</Name>
<Coord X="7.065" Y="1.889" Z="2.690"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0018</Name>
<SubId ID="11018"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.659" Y="6.126" X="5.369"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0005</Name>
<SubId ID="11005"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.496" Y="-0.13" X="6.066"></Coord>
<Dir Z="-0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_7</Name>
<SubId ID="16007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="4.260" Y="5.209" X="5.810"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_8</Name>
<SubId ID="16008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="2.990" Y="1.032" X="6.109"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_203</Name>
<SubId ID="2203"></SubId>
<Group>
<Name>undest_room_203</Name>
<BBox_Min Z="2.490" Y="1.889" X="7.065"></BBox_Min>
<BBox_Max Z="5.400" Y="6.134" X="12.005"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.690" Y="2.064" X="7.240"></BBox_Min>
<BBox_Max Z="2.690" Y="5.836" X="11.830"></BBox_Max>
<Polygon>
<Name>p1933</Name>
<Vertex>
<Name>p1933/V1</Name>
<Coord X="11.830" Y="5.836" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p1933/V2</Name>
<Coord X="7.240" Y="5.836" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p1933/V3</Name>
<Coord X="7.240" Y="2.064" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p1933/V4</Name>
<Coord X="11.830" Y="2.064" Z="2.690"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0017</Name>
<SubId ID="11017"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.594" Y="6.125" X="9.57"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0011</Name>
<SubId ID="11011"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.492" Y="4.3" X="12.110999999999999"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_9</Name>
<SubId ID="16009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="2.990" Y="3.950" X="9.535"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_8</Name>
<SubId ID="14008"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.828" Y="5.836" X="7.847"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_204</Name>
<SubId ID="2204"></SubId>
<Group>
<Name>undest_room_204</Name>
<BBox_Min Z="2.490" Y="-0.134" X="7.665"></BBox_Min>
<BBox_Max Z="5.400" Y="2.064" X="12.005"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.690" Y="0.175" X="7.840"></BBox_Min>
<BBox_Max Z="2.690" Y="1.889" X="11.830"></BBox_Max>
<Polygon>
<Name>p1934</Name>
<Vertex>
<Name>p1934/V1</Name>
<Coord X="11.830" Y="1.889" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p1934/V2</Name>
<Coord X="7.840" Y="1.889" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p1934/V3</Name>
<Coord X="7.840" Y="0.175" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p1934/V4</Name>
<Coord X="11.830" Y="0.175" Z="2.690"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0010</Name>
<SubId ID="11010"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.474" Y="1.395" X="12.119"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0006</Name>
<SubId ID="11006"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.477" Y="-0.125" X="9.996"></Coord>
<Dir Z="-0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_10</Name>
<SubId ID="16010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="2.990" Y="1.032" X="9.835"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_7</Name>
<SubId ID="14007"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.828" Y="0.970" X="11.830"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_3</Name>
<Comment>base_height=5.4</Comment>
<Switch>
<Name>SW_room_301</Name>
<SubId ID="2301"></SubId>
<Group>
<Name>undest_room_301</Name>
<BBox_Min Z="5.199" Y="-0.713" X="-0.200"></BBox_Min>
<BBox_Max Z="8.629" Y="6.713" X="12.220"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="5.400" Y="0.175" X="0.200"></BBox_Min>
<BBox_Max Z="5.400" Y="5.836" X="11.830"></BBox_Max>
<Polygon>
<Name>p1930</Name>
<Vertex>
<Name>p1930/V1</Name>
<Coord X="11.830" Y="5.836" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p1930/V2</Name>
<Coord X="0.200" Y="5.836" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p1930/V3</Name>
<Coord X="0.200" Y="0.175" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p1930/V4</Name>
<Coord X="11.830" Y="0.175" Z="5.400"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0020</Name>
<SubId ID="11020"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="7.96626" Y="5.566999999999999" X="2.362"></Coord>
<Dir Z="0.866" Y="0.500" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0007</Name>
<SubId ID="11007"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="7.80126" Y="0.426" X="9.66"></Coord>
<Dir Z="0.866" Y="-0.500" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_11</Name>
<SubId ID="16011"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="5.700" Y="3.336" X="2.302"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_12</Name>
<SubId ID="16012"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="5.700" Y="3.336" X="9.693"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_9</Name>
<SubId ID="14009"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="7.682" Y="3.000" X="11.830"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_6</Name>
<SubId ID="14006"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="6.438" Y="5.836" X="5.194"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_4</Name>
<Comment>base_height=8.63</Comment>
<Switch>
<Name>SW_room_401</Name>
<SubId ID="2401"></SubId>
<Group>
<Name>undest_room_401</Name>
<BBox_Min Z="6.397" Y="-0.713" X="-0.200"></BBox_Min>
<BBox_Max Z="8.629" Y="6.713" X="12.220"></BBox_Max>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="2.240" Y="-0.100" X="0.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="2.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="6.002"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="9.505"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.500" X="13.005"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_5</Name>
<SubId ID="15005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.511" X="13.005"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_6</Name>
<SubId ID="15006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.011" X="9.505"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_7</Name>
<SubId ID="15007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.011" X="6.002"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_8</Name>
<SubId ID="15008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.011" X="2.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_9</Name>
<SubId ID="15009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.511" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_10</Name>
<SubId ID="15010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.500" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.594" Y="0.275" X="8.936"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_2</Name>
<SubId ID="27002"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="3.256" Y="0.275" X="8.936"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>