Files
qt6-migration-pipeline/external/BuildingModels/StaticMeshes/bldg_4139.flt.xml
T
2026-10-23 16:13:31 +00:00

614 lines
31 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Tue Dec 07 14:48:57 2021 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_4139</Name>
<ModelId Id="1139"></ModelId>
<BBox_Min Z="-0.300" Y="-1.140" X="-1.140"></BBox_Min>
<BBox_Max Z="6.685" Y="6.970" X="13.140"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.000" X="0.000"></BBox_Min>
<BBox_Max Z="0.000" Y="6.000" X="12.130"></BBox_Max>
<Polygon>
<Name>p4415</Name>
<Vertex>
<Name>p4415/V1</Name>
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4415/V2</Name>
<Coord X="12.130" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4415/V3</Name>
<Coord X="12.130" Y="6.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4415/V4</Name>
<Coord X="0.000" Y="6.000" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0.00</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.300" Y="-0.124" X="0.000"></BBox_Min>
<BBox_Max Z="2.710" Y="3.688" X="2.960"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="0.090"></BBox_Min>
<BBox_Max Z="0.000" Y="3.508" X="2.780"></BBox_Max>
<Polygon>
<Name>p4411</Name>
<Vertex>
<Name>p4411/V1</Name>
<Coord X="2.780" Y="3.508" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4411/V2</Name>
<Coord X="0.090" Y="3.508" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4411/V3</Name>
<Coord X="0.090" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4411/V4</Name>
<Coord X="2.780" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.149" Y="-0.148" X="1.345"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.834" X="1.407"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.124" Y="1.258" X="0.090"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_102</Name>
<SubId ID="2102"></SubId>
<Group>
<Name>undest_room_102</Name>
<BBox_Min Z="-0.300" Y="3.508" X="0.000"></BBox_Min>
<BBox_Max Z="2.710" Y="6.072" X="9.385"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="3.688" X="0.090"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="9.205"></BBox_Max>
<Polygon>
<Name>p4412</Name>
<Vertex>
<Name>p4412/V1</Name>
<Coord X="0.090" Y="3.688" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4412/V2</Name>
<Coord X="9.205" Y="3.688" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4412/V3</Name>
<Coord X="9.205" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4412/V4</Name>
<Coord X="0.090" Y="5.820" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0010</Name>
<SubId ID="11010"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.008" Y="6.1610000000000005" X="1.542"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0009</Name>
<SubId ID="11009"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.166" Y="6.237" X="6.49"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.717" X="1.624"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_3</Name>
<SubId ID="16003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.752" X="7.846"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_2</Name>
<SubId ID="14002"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.124" Y="5.027" X="0.090"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_103</Name>
<SubId ID="2103"></SubId>
<Group>
<Name>undest_room_103</Name>
<BBox_Min Z="-0.300" Y="-0.124" X="9.205"></BBox_Min>
<BBox_Max Z="2.710" Y="6.072" X="12.130"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="9.385"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="12.040"></BBox_Max>
<Polygon>
<Name>p4413</Name>
<Vertex>
<Name>p4413/V1</Name>
<Coord X="12.040" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4413/V2</Name>
<Coord X="9.385" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4413/V3</Name>
<Coord X="9.385" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4413/V4</Name>
<Coord X="12.040" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0008</Name>
<SubId ID="11008"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.157" Y="6.238" X="11.327"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0004</Name>
<SubId ID="11004"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.165" Y="-0.153" X="10.257"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_4</Name>
<SubId ID="16004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="2.975" X="10.616"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_3</Name>
<SubId ID="14003"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.124" Y="0.180" X="11.765"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_104</Name>
<SubId ID="2104"></SubId>
<Group>
<Name>undest_room_104</Name>
<BBox_Min Z="-0.300" Y="-0.072" X="2.780"></BBox_Min>
<BBox_Max Z="3.815" Y="3.688" X="9.386"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="2.960"></BBox_Min>
<BBox_Max Z="0.000" Y="3.508" X="9.206"></BBox_Max>
<Polygon>
<Name>p4414</Name>
<Vertex>
<Name>p4414/V1</Name>
<Coord X="9.206" Y="3.508" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4414/V2</Name>
<Coord X="2.960" Y="3.508" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4414/V3</Name>
<Coord X="2.960" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p4414/V4</Name>
<Coord X="9.206" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.157" Y="-0.151" X="4.899"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0003</Name>
<SubId ID="11003"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.423" Y="-0.127" X="7.886"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_5</Name>
<SubId ID="16005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.180" X="7.831"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_6</Name>
<SubId ID="16006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="2.925" X="3.678"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=2.71</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.510" Y="-0.340" X="0.000"></BBox_Min>
<BBox_Max Z="5.927" Y="3.688" X="2.960"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.710" Y="0.180" X="0.090"></BBox_Min>
<BBox_Max Z="2.710" Y="3.508" X="2.780"></BBox_Max>
<Polygon>
<Name>p3901</Name>
<Vertex>
<Name>p3901/V1</Name>
<Coord X="2.780" Y="3.508" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p3901/V2</Name>
<Coord X="0.090" Y="3.508" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p3901/V3</Name>
<Coord X="0.090" Y="0.180" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p3901/V4</Name>
<Coord X="2.780" Y="0.180" Z="2.710"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0005</Name>
<SubId ID="11005"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.785" Y="-0.07400000000000001" X="1.456"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_4</Name>
<SubId ID="14004"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.953" Y="1.438" X="0.090"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_202</Name>
<SubId ID="2202"></SubId>
<Group>
<Name>undest_room_202</Name>
<BBox_Min Z="2.510" Y="3.508" X="0.000"></BBox_Min>
<BBox_Max Z="5.583" Y="6.000" X="9.385"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.710" Y="3.688" X="0.090"></BBox_Min>
<BBox_Max Z="2.710" Y="5.820" X="9.205"></BBox_Max>
<Polygon>
<Name>p3902</Name>
<Vertex>
<Name>p3902/V1</Name>
<Coord X="9.205" Y="5.820" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p3902/V2</Name>
<Coord X="0.090" Y="5.820" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p3902/V3</Name>
<Coord X="0.090" Y="3.688" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p3902/V4</Name>
<Coord X="9.205" Y="3.688" Z="2.710"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0012</Name>
<SubId ID="11012"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.609" Y="6.166" X="5.763"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_8</Name>
<SubId ID="16008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.084" Y="4.741" X="2.044"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_12</Name>
<SubId ID="16012"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.084" Y="4.712" X="7.202"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_5</Name>
<SubId ID="14005"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.953" Y="4.851" X="0.090"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_203</Name>
<SubId ID="2203"></SubId>
<Group>
<Name>undest_room_203</Name>
<BBox_Min Z="2.510" Y="-0.340" X="2.780"></BBox_Min>
<BBox_Max Z="5.583" Y="6.000" X="12.130"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.710" Y="0.180" X="2.960"></BBox_Min>
<BBox_Max Z="2.710" Y="5.820" X="12.040"></BBox_Max>
<Polygon>
<Name>p3903</Name>
<Vertex>
<Name>p3903/V1</Name>
<Coord X="12.040" Y="5.820" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p3903/V2</Name>
<Coord X="9.385" Y="5.820" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p3903/V3</Name>
<Coord X="9.385" Y="3.508" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p3903/V4</Name>
<Coord X="2.960" Y="3.508" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p3903/V5</Name>
<Coord X="2.960" Y="0.180" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p3903/V6</Name>
<Coord X="12.040" Y="0.180" Z="2.710"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0007</Name>
<SubId ID="11007"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.604" Y="-0.079" X="10.564"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0006</Name>
<SubId ID="11006"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.649" Y="-0.079" X="5.156"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0011</Name>
<SubId ID="11011"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.645" Y="6.16" X="10.572"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_9</Name>
<SubId ID="16009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.084" Y="2.938" X="10.719"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_10</Name>
<SubId ID="16010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.084" Y="1.078" X="4.492"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_6</Name>
<SubId ID="14006"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.953" Y="2.706" X="12.040"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_3</Name>
<Comment>base_height=5.4</Comment>
<Switch>
<Name>SW_room_301</Name>
<SubId ID="2301"></SubId>
<Group>
<Name>undest_room_301</Name>
<BBox_Min Z="5.197" Y="-0.370" X="0.000"></BBox_Min>
<BBox_Max Z="6.685" Y="6.000" X="12.130"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="5.403" Y="0.000" X="0.090"></BBox_Min>
<BBox_Max Z="5.403" Y="5.820" X="12.040"></BBox_Max>
<Polygon>
<Name>p3520</Name>
<Vertex>
<Name>p3520/V1</Name>
<Coord X="12.040" Y="5.820" Z="5.403"></Coord>
</Vertex>
<Vertex>
<Name>p3520/V2</Name>
<Coord X="0.090" Y="5.820" Z="5.403"></Coord>
</Vertex>
<Vertex>
<Name>p3520/V3</Name>
<Coord X="0.090" Y="0.000" Z="5.403"></Coord>
</Vertex>
<Vertex>
<Name>p3520/V4</Name>
<Coord X="12.040" Y="0.000" Z="5.403"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>IPS_IN_AP_11</Name>
<SubId ID="16011"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="6.010" Y="3.110" X="6.148"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="2.260" Y="-0.100" X="0.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="1.321" X="-1.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="4.330" X="-1.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="6.900" X="2.500"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="6.900" X="6.000"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_5</Name>
<SubId ID="15005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="6.900" X="9.500"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_6</Name>
<SubId ID="15006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="4.330" X="13.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_7</Name>
<SubId ID="15007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="1.321" X="13.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_8</Name>
<SubId ID="15008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.070" X="9.500"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_9</Name>
<SubId ID="15009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.070" X="6.000"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_10</Name>
<SubId ID="15010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.070" X="2.500"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.550" Y="3.036" X="3.060"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_2</Name>
<SubId ID="27002"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="3.413" Y="2.517" X="3.060"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>