Files
qt6-migration-pipeline/external/BuildingModels/StaticMeshes/bldg_4195.flt.xml
T
2026-10-23 16:13:31 +00:00

344 lines
17 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Wed Jan 05 13:50:27 2022 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_4195</Name>
<ModelId Id="1195"></ModelId>
<BBox_Min Z="-0.300" Y="-1.070" X="-1.070"></BBox_Min>
<BBox_Max Z="3.990" Y="7.070" X="7.057"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.000" X="0.000"></BBox_Min>
<BBox_Max Z="0.000" Y="6.000" X="5.987"></BBox_Max>
<Polygon>
<Name>p1332</Name>
<Vertex>
<Name>p1332/V1</Name>
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1332/V2</Name>
<Coord X="5.987" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1332/V3</Name>
<Coord X="5.987" Y="6.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1332/V4</Name>
<Coord X="0.000" Y="6.000" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0.00</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.300" Y="-0.203" X="0.000"></BBox_Min>
<BBox_Max Z="2.890" Y="6.000" X="2.320"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="0.090"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="2.030"></BBox_Max>
<Polygon>
<Name>p1451</Name>
<Vertex>
<Name>p1451/V1</Name>
<Coord X="2.030" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1451/V2</Name>
<Coord X="0.090" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1451/V3</Name>
<Coord X="0.090" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1451/V4</Name>
<Coord X="2.030" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.048" Y="-0.248" X="0.372"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0007</Name>
<SubId ID="11007"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.295" Y="6.061" X="1.081"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.000" X="1.060"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.128" Y="5.820" X="0.432"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_102</Name>
<SubId ID="2102"></SubId>
<Group>
<Name>undest_room_102</Name>
<BBox_Min Z="-0.300" Y="-0.342" X="2.030"></BBox_Min>
<BBox_Max Z="2.801" Y="3.579" X="6.056"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="2.210"></BBox_Min>
<BBox_Max Z="0.000" Y="3.170" X="5.807"></BBox_Max>
<Polygon>
<Name>p1453</Name>
<Vertex>
<Name>p1453/V1</Name>
<Coord X="5.807" Y="3.170" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1453/V2</Name>
<Coord X="2.210" Y="3.170" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1453/V3</Name>
<Coord X="2.210" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1453/V4</Name>
<Coord X="5.807" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.322" Y="-0.172" X="3.364"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0004</Name>
<SubId ID="11004"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.047" Y="1.605" X="6.187"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0003</Name>
<SubId ID="11003"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.899" Y="0.832" X="6.111000000000001"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.675" X="4.009"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_3</Name>
<SubId ID="14003"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.128" Y="3.170" X="4.831"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_103</Name>
<SubId ID="2103"></SubId>
<Group>
<Name>undest_room_103</Name>
<BBox_Min Z="-0.300" Y="3.170" X="2.030"></BBox_Min>
<BBox_Max Z="3.264" Y="6.068" X="5.987"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="3.350" X="2.210"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="5.807"></BBox_Max>
<Polygon>
<Name>p1452</Name>
<Vertex>
<Name>p1452/V1</Name>
<Coord X="5.807" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1452/V2</Name>
<Coord X="2.210" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1452/V3</Name>
<Coord X="2.210" Y="3.350" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p1452/V4</Name>
<Coord X="5.807" Y="3.350" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0005</Name>
<SubId ID="11005"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.322" Y="4.466" X="6.101"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0006</Name>
<SubId ID="11006"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.051" Y="6.138" X="5.192"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_3</Name>
<SubId ID="16003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.300" X="4.009"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_2</Name>
<SubId ID="14002"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.128" Y="5.301" X="5.807"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=2.7</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.494" Y="-0.372" X="0.000"></BBox_Min>
<BBox_Max Z="3.990" Y="6.000" X="5.987"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="0.000" X="0.090"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="5.807"></BBox_Max>
<Polygon>
<Name>p1456</Name>
<Vertex>
<Name>p1456/V1</Name>
<Coord X="5.807" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p1456/V2</Name>
<Coord X="0.090" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p1456/V3</Name>
<Coord X="0.090" Y="0.000" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p1456/V4</Name>
<Coord X="5.807" Y="0.000" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>IPS_IN_AP_4</Name>
<SubId ID="16004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.092" Y="2.910" X="2.949"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="2.250" Y="0.100" X="-0.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="1.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="4.487"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.500" X="6.987"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.500" X="6.987"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_5</Name>
<SubId ID="15005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.000" X="4.487"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_6</Name>
<SubId ID="15006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.000" X="1.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_7</Name>
<SubId ID="15007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.500" X="-0.987"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_8</Name>
<SubId ID="15008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.500" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.493" Y="5.678" X="2.323"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>