Files
2026-10-23 16:13:31 +00:00

481 lines
24 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Tue Jan 11 13:04:18 2022 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_3199</Name>
<ModelId Id="1199"></ModelId>
<BBox_Min Z="-0.300" Y="-7.086" X="-4.070"></BBox_Min>
<BBox_Max Z="6.676" Y="1.070" X="3.795"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="-6.016" X="-3.000"></BBox_Min>
<BBox_Max Z="0.000" Y="0.000" X="2.725"></BBox_Max>
<Polygon>
<Name>p3684</Name>
<Vertex>
<Name>p3684/V1</Name>
<Coord X="-3.000" Y="-6.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3684/V2</Name>
<Coord X="0.000" Y="-6.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3684/V3</Name>
<Coord X="2.725" Y="-6.016" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3684/V4</Name>
<Coord X="2.725" Y="-1.078" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3684/V5</Name>
<Coord X="0.000" Y="-1.078" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3684/V6</Name>
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3684/V7</Name>
<Coord X="-3.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0.00</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.300" Y="-6.090" X="-3.132"></BBox_Min>
<BBox_Max Z="2.700" Y="0.090" X="0.000"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="-5.820" X="-2.820"></BBox_Min>
<BBox_Max Z="0.000" Y="-0.180" X="-0.180"></BBox_Max>
<Polygon>
<Name>p3688</Name>
<Vertex>
<Name>p3688/V1</Name>
<Coord X="-0.180" Y="-0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3688/V2</Name>
<Coord X="-2.820" Y="-0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3688/V3</Name>
<Coord X="-2.820" Y="-5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3688/V4</Name>
<Coord X="-0.180" Y="-5.820" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0008</Name>
<SubId ID="11008"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.138" Y="0.189" X="-0.685"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.155" Y="-0.715" X="-3.186"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.012" Y="-4.52" X="-3.109"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0004</Name>
<SubId ID="11004"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.157" Y="-6.211" X="-1.827"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0006</Name>
<SubId ID="11006"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.45" Y="-2.112" X="0.116"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-3.000" X="-1.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.319" Y="-5.820" X="-2.485"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_102</Name>
<SubId ID="2102"></SubId>
<Group>
<Name>undest_room_102</Name>
<BBox_Min Z="0.000" Y="-6.016" X="-0.180"></BBox_Min>
<BBox_Max Z="3.765" Y="-0.180" X="2.775"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="-6.000" X="-0.000"></BBox_Min>
<BBox_Max Z="0.000" Y="-2.360" X="2.725"></BBox_Max>
<Polygon>
<Name>p3689</Name>
<Vertex>
<Name>p3689/V1</Name>
<Coord X="0.000" Y="-6.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3689/V2</Name>
<Coord X="2.725" Y="-6.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3689/V3</Name>
<Coord X="2.725" Y="-2.360" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3689/V4</Name>
<Coord X="-0.000" Y="-2.360" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>subroom_1</Name>
<BBox_Min Z="1.257" Y="-6.016" X="0.196"></BBox_Min>
<BBox_Max Z="1.257" Y="-4.697" X="2.725"></BBox_Max>
</Group>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="1.557" Y="-5.356" X="1.461"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=2.7</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.500" Y="-6.000" X="-3.333"></BBox_Min>
<BBox_Max Z="5.489" Y="0.000" X="0.000"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="-5.820" X="-2.820"></BBox_Min>
<BBox_Max Z="2.700" Y="-0.180" X="-0.180"></BBox_Max>
<Polygon>
<Name>p3691</Name>
<Vertex>
<Name>p3691/V1</Name>
<Coord X="-2.820" Y="-5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p3691/V2</Name>
<Coord X="-0.180" Y="-5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p3691/V3</Name>
<Coord X="-0.180" Y="-0.180" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p3691/V4</Name>
<Coord X="-2.820" Y="-0.180" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0009</Name>
<SubId ID="11009"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.594" Y="0.112" X="-1.489"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0003</Name>
<SubId ID="11003"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.626" Y="-4.505" X="-3.114"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0005</Name>
<SubId ID="11005"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.616" Y="-6.13" X="-1.505"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0007</Name>
<SubId ID="11007"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="5.134" Y="-2.105" X="0.118"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_3</Name>
<SubId ID="16003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.000" Y="-3.000" X="-1.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_2</Name>
<SubId ID="14002"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.873" Y="-5.820" X="-2.331"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_202</Name>
<SubId ID="2202"></SubId>
<Group>
<Name>undest_room_202</Name>
<BBox_Min Z="2.474" Y="-6.016" X="-0.390"></BBox_Min>
<BBox_Max Z="6.676" Y="-0.180" X="2.775"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.694" Y="-6.000" X="0.000"></BBox_Min>
<BBox_Max Z="2.700" Y="-1.078" X="2.725"></BBox_Max>
<Polygon>
<Name>p3692</Name>
<Vertex>
<Name>p3692/V1</Name>
<Coord X="2.725" Y="-1.078" Z="2.694"></Coord>
</Vertex>
<Vertex>
<Name>p3692/V2</Name>
<Coord X="0.000" Y="-1.078" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p3692/V3</Name>
<Coord X="0.000" Y="-6.000" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p3692/V4</Name>
<Coord X="2.725" Y="-6.000" Z="2.694"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>subroom_2</Name>
<BBox_Min Z="2.694" Y="-2.546" X="0.000"></BBox_Min>
<BBox_Max Z="2.694" Y="-1.078" X="2.725"></BBox_Max>
</Group>
<Group>
<Name>subroom_3</Name>
<BBox_Min Z="4.135" Y="-6.016" X="0.196"></BBox_Min>
<BBox_Max Z="4.135" Y="-4.697" X="2.725"></BBox_Max>
</Group>
<External_Reference>
<Name>IPS_IN_AP_4</Name>
<SubId ID="16004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="2.994" Y="-1.812" X="1.362"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_5</Name>
<SubId ID="16005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="4.435" Y="-5.356" X="1.461"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_3</Name>
<Comment>base_height=5.4</Comment>
<Switch>
<Name>SW_room_301</Name>
<SubId ID="2301"></SubId>
<Group>
<Name>undest_room_301</Name>
<BBox_Min Z="5.195" Y="-6.000" X="-3.363"></BBox_Min>
<BBox_Max Z="6.669" Y="0.000" X="0.000"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="5.483" Y="-5.820" X="-3.000"></BBox_Min>
<BBox_Max Z="5.483" Y="-0.180" X="-0.180"></BBox_Max>
<Polygon>
<Name>p3696_1</Name>
<Vertex>
<Name>p3696_1/V1</Name>
<Coord X="-0.180" Y="-0.180" Z="5.483"></Coord>
</Vertex>
<Vertex>
<Name>p3696_1/V2</Name>
<Coord X="-3.000" Y="-0.180" Z="5.483"></Coord>
</Vertex>
<Vertex>
<Name>p3696_1/V3</Name>
<Coord X="-3.000" Y="-5.820" Z="5.483"></Coord>
</Vertex>
<Vertex>
<Name>p3696_1/V4</Name>
<Coord X="-0.180" Y="-5.820" Z="5.483"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>subroom_4</Name>
<BBox_Min Z="5.400" Y="-5.820" X="-3.000"></BBox_Min>
<BBox_Max Z="5.483" Y="-0.180" X="-0.180"></BBox_Max>
</Group>
<External_Reference>
<Name>IPS_IN_AP_6</Name>
<SubId ID="16006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="5.742" Y="-3.000" X="-1.590"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_302</Name>
<SubId ID="2302"></SubId>
<Group>
<Name>undest_room_302</Name>
<BBox_Min Z="5.350" Y="-2.546" X="0.000"></BBox_Min>
<BBox_Max Z="6.676" Y="-1.078" X="2.775"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="5.573" Y="-2.546" X="0.000"></BBox_Min>
<BBox_Max Z="5.573" Y="-1.078" X="2.725"></BBox_Max>
<Polygon>
<Name>p3697</Name>
<Vertex>
<Name>p3697/V1</Name>
<Coord X="2.725" Y="-1.078" Z="5.573"></Coord>
</Vertex>
<Vertex>
<Name>p3697/V2</Name>
<Coord X="0.000" Y="-1.078" Z="5.573"></Coord>
</Vertex>
<Vertex>
<Name>p3697/V3</Name>
<Coord X="0.000" Y="-2.546" Z="5.573"></Coord>
</Vertex>
<Vertex>
<Name>p3697/V4</Name>
<Coord X="2.725" Y="-2.546" Z="5.573"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>IPS_IN_AP_7</Name>
<SubId ID="16007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="5.873" Y="-1.812" X="1.362"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="2.250" Y="0.100" X="-0.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.000" X="-1.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.000" X="1.352"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.500" X="3.725"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-4.500" X="3.725"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_5</Name>
<SubId ID="15005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-7.016" X="1.352"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_6</Name>
<SubId ID="15006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-7.016" X="-1.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_7</Name>
<SubId ID="15007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-4.500" X="-4.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_8</Name>
<SubId ID="15008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.500" X="-4.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.506" Y="-3.411" X="-2.662"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_2</Name>
<SubId ID="27002"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="3.283" Y="-2.457" X="-2.692"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>