960 lines
50 KiB
XML
Executable File
960 lines
50 KiB
XML
Executable File
<?xml version="1.0" ?>
|
|
<!--fltHdrLastDate Fri Dec 03 11:12:46 2021 - PostProcessed by SLTE $Rev: 56086 $-->
|
|
<STREIF>
|
|
<Header>
|
|
<Group>
|
|
<Name>bldg_3229</Name>
|
|
<ModelId Id="1229"></ModelId>
|
|
<BBox_Min Z="-0.300" Y="-1.140" X="-1.140"></BBox_Min>
|
|
<BBox_Max Z="11.341" Y="7.140" X="19.140"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="0.000" X="0.000"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="6.000" X="17.970"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p6742</Name>
|
|
<Vertex>
|
|
<Name>p6742/V1</Name>
|
|
<Coord X="17.970" Y="6.000" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6742/V2</Name>
|
|
<Coord X="0.000" Y="6.000" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6742/V3</Name>
|
|
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6742/V4</Name>
|
|
<Coord X="17.970" Y="0.000" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<Group>
|
|
<Name>floor_1</Name>
|
|
<Comment>base_height=0.00</Comment>
|
|
<Switch>
|
|
<Name>SW_room_101</Name>
|
|
<SubId ID="2101"></SubId>
|
|
<Group>
|
|
<Name>undest_room_101</Name>
|
|
<BBox_Min Z="-0.300" Y="0.000" X="0.000"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="6.075" X="3.153"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="0.180" X="0.090"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="5.820" X="2.973"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p6185_2</Name>
|
|
<Vertex>
|
|
<Name>p6185_2/V1</Name>
|
|
<Coord X="2.973" Y="5.820" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6185_2/V2</Name>
|
|
<Coord X="0.090" Y="5.820" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6185_2/V3</Name>
|
|
<Coord X="0.090" Y="0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6185_2/V4</Name>
|
|
<Coord X="2.973" Y="0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0015</Name>
|
|
<SubId ID="11015"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.148" Y="6.178" X="1.856"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0001</Name>
|
|
<SubId ID="11001"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.012" Y="-0.121" X="1.297"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_1</Name>
|
|
<SubId ID="14001"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.206" Y="5.820" X="0.640"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_1</Name>
|
|
<SubId ID="16001"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="2.992" X="1.609"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_102</Name>
|
|
<SubId ID="2102"></SubId>
|
|
<Group>
|
|
<Name>undest_room_102</Name>
|
|
<BBox_Min Z="-0.300" Y="0.000" X="2.973"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="6.000" X="10.453"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="0.180" X="3.153"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="5.820" X="10.273"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p6186_2</Name>
|
|
<Vertex>
|
|
<Name>p6186_2/V1</Name>
|
|
<Coord X="10.273" Y="5.820" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6186_2/V2</Name>
|
|
<Coord X="3.153" Y="5.820" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6186_2/V3</Name>
|
|
<Coord X="3.153" Y="0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6186_2/V4</Name>
|
|
<Coord X="5.543" Y="0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6186_2/V5</Name>
|
|
<Coord X="5.543" Y="4.611" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6186_2/V6</Name>
|
|
<Coord X="9.081" Y="4.611" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6186_2/V7</Name>
|
|
<Coord X="9.081" Y="2.951" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6186_2/V8</Name>
|
|
<Coord X="10.273" Y="2.951" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0014</Name>
|
|
<SubId ID="11014"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.397" Y="6.105" X="4.565"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0002</Name>
|
|
<SubId ID="11002"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.498" Y="-0.125" X="3.628"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_2</Name>
|
|
<SubId ID="14002"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.206" Y="5.820" X="3.503"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_2</Name>
|
|
<SubId ID="16002"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="1.487" X="4.378"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_3</Name>
|
|
<SubId ID="16003"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="4.921" X="4.425"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_103</Name>
|
|
<SubId ID="2103"></SubId>
|
|
<Group>
|
|
<Name>undest_room_103</Name>
|
|
<BBox_Min Z="-0.300" Y="-0.151" X="5.543"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="6.156" X="17.970"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="0.180" X="5.723"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="5.820" X="17.880"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p6187_2</Name>
|
|
<Vertex>
|
|
<Name>p6187_2/V1</Name>
|
|
<Coord X="10.453" Y="2.951" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6187_2/V2</Name>
|
|
<Coord X="8.901" Y="2.951" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6187_2/V3</Name>
|
|
<Coord X="8.901" Y="4.431" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6187_2/V4</Name>
|
|
<Coord X="5.723" Y="4.431" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6187_2/V5</Name>
|
|
<Coord X="5.723" Y="0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6187_2/V6</Name>
|
|
<Coord X="17.880" Y="0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6187_2/V7</Name>
|
|
<Coord X="17.880" Y="5.820" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6187_2/V8</Name>
|
|
<Coord X="10.453" Y="5.820" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0013</Name>
|
|
<SubId ID="11013"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.144" Y="6.183000000000001" X="12.311"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0004</Name>
|
|
<SubId ID="11004"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.184" Y="-0.197" X="14.606"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0003</Name>
|
|
<SubId ID="11003"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.18" Y="-0.198" X="8.925"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_3</Name>
|
|
<SubId ID="14003"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.213" Y="0.977" X="17.880"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_4</Name>
|
|
<SubId ID="16004"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="2.160" X="7.409"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_5</Name>
|
|
<SubId ID="16005"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.374" Y="2.944" X="14.236"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
</Group>
|
|
<Group>
|
|
<Name>floor_2</Name>
|
|
<Comment>base_height=2.7</Comment>
|
|
<Switch>
|
|
<Name>SW_room_201</Name>
|
|
<SubId ID="2201"></SubId>
|
|
<Group>
|
|
<Name>undest_room_201</Name>
|
|
<BBox_Min Z="2.500" Y="0.000" X="0.000"></BBox_Min>
|
|
<BBox_Max Z="5.400" Y="6.000" X="3.153"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="2.700" Y="0.180" X="0.090"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="5.820" X="2.973"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p6185_1</Name>
|
|
<Vertex>
|
|
<Name>p6185_1/V1</Name>
|
|
<Coord X="2.973" Y="5.820" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6185_1/V2</Name>
|
|
<Coord X="0.090" Y="5.820" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6185_1/V3</Name>
|
|
<Coord X="0.090" Y="0.180" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6185_1/V4</Name>
|
|
<Coord X="2.973" Y="0.180" Z="2.700"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0018</Name>
|
|
<SubId ID="11018"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="3.609" Y="6.109" X="1.603"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0005</Name>
|
|
<SubId ID="11005"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="4.668" Y="-0.119" X="1.303"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_4</Name>
|
|
<SubId ID="14004"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="4.906" Y="5.820" X="0.640"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_6</Name>
|
|
<SubId ID="16006"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="3.074" Y="2.992" X="1.609"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_202</Name>
|
|
<SubId ID="2202"></SubId>
|
|
<Group>
|
|
<Name>undest_room_202</Name>
|
|
<BBox_Min Z="2.500" Y="0.000" X="2.973"></BBox_Min>
|
|
<BBox_Max Z="5.400" Y="6.000" X="10.453"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="2.700" Y="0.180" X="3.153"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="5.820" X="10.273"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p6186_1</Name>
|
|
<Vertex>
|
|
<Name>p6186_1/V1</Name>
|
|
<Coord X="10.273" Y="5.820" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6186_1/V2</Name>
|
|
<Coord X="3.153" Y="5.820" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6186_1/V3</Name>
|
|
<Coord X="3.153" Y="0.180" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6186_1/V4</Name>
|
|
<Coord X="5.543" Y="0.180" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6186_1/V5</Name>
|
|
<Coord X="5.543" Y="4.611" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6186_1/V6</Name>
|
|
<Coord X="9.081" Y="4.611" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6186_1/V7</Name>
|
|
<Coord X="9.081" Y="2.951" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6186_1/V8</Name>
|
|
<Coord X="10.273" Y="2.951" Z="2.700"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0017</Name>
|
|
<SubId ID="11017"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="4.627" Y="6.112" X="4.581"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0006</Name>
|
|
<SubId ID="11006"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="3.618" Y="-0.119" X="3.966"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_5</Name>
|
|
<SubId ID="14005"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="3.784" Y="5.176" X="10.273"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_10</Name>
|
|
<SubId ID="14010"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="4.900" Y="0.180" X="5.039"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_7</Name>
|
|
<SubId ID="16007"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="3.074" Y="1.487" X="4.378"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_8</Name>
|
|
<SubId ID="16008"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="3.074" Y="4.921" X="4.425"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_203</Name>
|
|
<SubId ID="2203"></SubId>
|
|
<Group>
|
|
<Name>undest_room_203</Name>
|
|
<BBox_Min Z="2.500" Y="-0.151" X="5.543"></BBox_Min>
|
|
<BBox_Max Z="5.400" Y="6.156" X="17.970"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="2.700" Y="0.180" X="5.723"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="5.820" X="17.880"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p6187_1</Name>
|
|
<Vertex>
|
|
<Name>p6187_1/V1</Name>
|
|
<Coord X="10.453" Y="2.951" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6187_1/V2</Name>
|
|
<Coord X="8.901" Y="2.951" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6187_1/V3</Name>
|
|
<Coord X="8.901" Y="4.431" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6187_1/V4</Name>
|
|
<Coord X="5.723" Y="4.431" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6187_1/V5</Name>
|
|
<Coord X="5.723" Y="0.180" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6187_1/V6</Name>
|
|
<Coord X="17.880" Y="0.180" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6187_1/V7</Name>
|
|
<Coord X="17.880" Y="5.820" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6187_1/V8</Name>
|
|
<Coord X="10.453" Y="5.820" Z="2.700"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0016</Name>
|
|
<SubId ID="11016"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="3.606" Y="6.106000000000001" X="12.02"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0008</Name>
|
|
<SubId ID="11008"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="3.64" Y="-0.112" X="14.891"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0007</Name>
|
|
<SubId ID="11007"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="3.638" Y="-0.115" X="9.198"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_8</Name>
|
|
<SubId ID="14008"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="4.900" Y="0.616" X="17.880"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_9</Name>
|
|
<SubId ID="16009"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="3.074" Y="2.160" X="7.409"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_10</Name>
|
|
<SubId ID="16010"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="3.074" Y="2.944" X="14.236"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
</Group>
|
|
<Group>
|
|
<Name>floor_3</Name>
|
|
<Comment>base_height=5.4</Comment>
|
|
<Switch>
|
|
<Name>SW_room_301</Name>
|
|
<SubId ID="2301"></SubId>
|
|
<Group>
|
|
<Name>undest_room_301</Name>
|
|
<BBox_Min Z="5.200" Y="0.000" X="0.000"></BBox_Min>
|
|
<BBox_Max Z="8.100" Y="6.000" X="3.153"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="5.400" Y="0.180" X="0.090"></BBox_Min>
|
|
<BBox_Max Z="5.400" Y="5.820" X="2.973"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p6185</Name>
|
|
<Vertex>
|
|
<Name>p6185/V1</Name>
|
|
<Coord X="2.973" Y="5.820" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6185/V2</Name>
|
|
<Coord X="0.090" Y="5.820" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6185/V3</Name>
|
|
<Coord X="0.090" Y="0.180" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6185/V4</Name>
|
|
<Coord X="2.973" Y="0.180" Z="5.400"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0020</Name>
|
|
<SubId ID="11020"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="6.312" Y="6.111000000000001" X="1.562"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_6</Name>
|
|
<SubId ID="14006"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="7.606" Y="5.820" X="0.640"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_11</Name>
|
|
<SubId ID="16011"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="5.774" Y="2.992" X="1.609"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_302</Name>
|
|
<SubId ID="2302"></SubId>
|
|
<Group>
|
|
<Name>undest_room_302</Name>
|
|
<BBox_Min Z="5.200" Y="0.000" X="2.973"></BBox_Min>
|
|
<BBox_Max Z="8.100" Y="6.000" X="10.453"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="5.400" Y="0.180" X="3.153"></BBox_Min>
|
|
<BBox_Max Z="5.400" Y="5.820" X="10.273"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p6186</Name>
|
|
<Vertex>
|
|
<Name>p6186/V1</Name>
|
|
<Coord X="10.273" Y="5.820" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6186/V2</Name>
|
|
<Coord X="3.153" Y="5.820" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6186/V3</Name>
|
|
<Coord X="3.153" Y="0.180" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6186/V4</Name>
|
|
<Coord X="5.543" Y="0.180" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6186/V5</Name>
|
|
<Coord X="5.543" Y="4.611" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6186/V6</Name>
|
|
<Coord X="9.081" Y="4.611" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6186/V7</Name>
|
|
<Coord X="9.081" Y="2.951" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6186/V8</Name>
|
|
<Coord X="10.273" Y="2.951" Z="5.400"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0009</Name>
|
|
<SubId ID="11009"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="6.37" Y="-0.12" X="3.902"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_7</Name>
|
|
<SubId ID="14007"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="6.484" Y="5.176" X="10.273"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_11</Name>
|
|
<SubId ID="14011"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="7.600" Y="0.180" X="5.039"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_12</Name>
|
|
<SubId ID="16012"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="5.774" Y="1.487" X="4.378"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_13</Name>
|
|
<SubId ID="16013"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="5.774" Y="4.921" X="4.425"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_303</Name>
|
|
<SubId ID="2303"></SubId>
|
|
<Group>
|
|
<Name>undest_room_303</Name>
|
|
<BBox_Min Z="5.200" Y="-0.151" X="5.543"></BBox_Min>
|
|
<BBox_Max Z="8.100" Y="6.156" X="17.970"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="5.400" Y="0.180" X="5.723"></BBox_Min>
|
|
<BBox_Max Z="5.400" Y="5.820" X="17.880"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p6187</Name>
|
|
<Vertex>
|
|
<Name>p6187/V1</Name>
|
|
<Coord X="10.453" Y="2.951" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6187/V2</Name>
|
|
<Coord X="8.901" Y="2.951" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6187/V3</Name>
|
|
<Coord X="8.901" Y="4.431" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6187/V4</Name>
|
|
<Coord X="5.723" Y="4.431" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6187/V5</Name>
|
|
<Coord X="5.723" Y="0.180" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6187/V6</Name>
|
|
<Coord X="17.880" Y="0.180" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6187/V7</Name>
|
|
<Coord X="17.880" Y="5.820" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p6187/V8</Name>
|
|
<Coord X="10.453" Y="5.820" Z="5.400"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0019</Name>
|
|
<SubId ID="11019"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="6.361" Y="6.109" X="12.018"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0011</Name>
|
|
<SubId ID="11011"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="6.359" Y="-0.114" X="14.837"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0010</Name>
|
|
<SubId ID="11010"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="6.357" Y="-0.12" X="9.171"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_14</Name>
|
|
<SubId ID="16014"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="5.774" Y="2.160" X="7.409"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_15</Name>
|
|
<SubId ID="16015"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="5.774" Y="2.944" X="14.236"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_12</Name>
|
|
<SubId ID="14012"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="7.600" Y="0.614" X="17.880"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
</Group>
|
|
<Group>
|
|
<Name>floor_4</Name>
|
|
<Comment>base_height=8.1</Comment>
|
|
<Switch>
|
|
<Name>SW_room_401</Name>
|
|
<SubId ID="2401"></SubId>
|
|
<Group>
|
|
<Name>undest_room_401</Name>
|
|
<BBox_Min Z="7.900" Y="-0.737" X="0.000"></BBox_Min>
|
|
<BBox_Max Z="11.341" Y="6.741" X="17.970"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="8.100" Y="0.180" X="0.090"></BBox_Min>
|
|
<BBox_Max Z="8.100" Y="5.820" X="17.880"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p5742</Name>
|
|
<Vertex>
|
|
<Name>p5742/V1</Name>
|
|
<Coord X="17.880" Y="5.820" Z="8.100"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p5742/V2</Name>
|
|
<Coord X="0.090" Y="5.820" Z="8.100"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p5742/V3</Name>
|
|
<Coord X="0.090" Y="0.180" Z="8.100"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p5742/V4</Name>
|
|
<Coord X="17.880" Y="0.180" Z="8.100"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0012</Name>
|
|
<SubId ID="11012"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="10.74226" Y="0.46" X="6.781"></Coord>
|
|
<Dir Z="0.866" Y="-0.500" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0021</Name>
|
|
<SubId ID="11021"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="10.70126" Y="5.54" X="12.663"></Coord>
|
|
<Dir Z="0.866" Y="0.500" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_9</Name>
|
|
<SubId ID="14009"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="10.305" Y="3.144" X="17.890"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_16</Name>
|
|
<SubId ID="16016"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="8.474" Y="3.081" X="3.072"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_17</Name>
|
|
<SubId ID="16017"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="8.474" Y="1.807" X="9.954"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_18</Name>
|
|
<SubId ID="16018"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="8.474" Y="3.024" X="14.738"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
</Group>
|
|
<Group>
|
|
<Name>floor_5</Name>
|
|
<Comment>base_height=11.34</Comment>
|
|
<Switch>
|
|
<Name>SW_room_501</Name>
|
|
<SubId ID="2501"></SubId>
|
|
<Group>
|
|
<Name>undest_room_501</Name>
|
|
<BBox_Min Z="9.085" Y="-0.737" X="0.000"></BBox_Min>
|
|
<BBox_Max Z="11.341" Y="6.741" X="17.970"></BBox_Max>
|
|
</Group>
|
|
</Switch>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>ZEG_MOD_AP_1</Name>
|
|
<SubId ID="12001"></SubId>
|
|
<Model NAME="ZEG_01.flt"></Model>
|
|
<Coord Z="2.250" Y="-0.100" X="0.100"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_1</Name>
|
|
<SubId ID="15001"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="1.478" X="-1.070"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_2</Name>
|
|
<SubId ID="15002"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="4.500" X="-1.070"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_3</Name>
|
|
<SubId ID="15003"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="7.070" X="2.500"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_4</Name>
|
|
<SubId ID="15004"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="7.070" X="6.786"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_5</Name>
|
|
<SubId ID="15005"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="7.070" X="11.072"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_6</Name>
|
|
<SubId ID="15006"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="7.070" X="15.358"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_7</Name>
|
|
<SubId ID="15007"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="-1.070" X="2.500"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_8</Name>
|
|
<SubId ID="15008"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="-1.070" X="6.786"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_9</Name>
|
|
<SubId ID="15009"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="-1.070" X="11.072"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_10</Name>
|
|
<SubId ID="15010"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="-1.070" X="15.358"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_11</Name>
|
|
<SubId ID="15011"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="4.500" X="19.070"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_12</Name>
|
|
<SubId ID="15012"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="1.478" X="19.070"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>BDI_P_1</Name>
|
|
<SubId ID="27001"></SubId>
|
|
<Model NAME="BDI.flt"></Model>
|
|
<Coord Z="0.600" Y="4.111" X="5.823"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>BDI_P_2</Name>
|
|
<SubId ID="27002"></SubId>
|
|
<Model NAME="BDI.flt"></Model>
|
|
<Coord Z="3.300" Y="4.118" X="5.823"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>BDI_P_3</Name>
|
|
<SubId ID="27003"></SubId>
|
|
<Model NAME="BDI.flt"></Model>
|
|
<Coord Z="6.000" Y="4.119" X="5.823"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Header>
|
|
</STREIF> |