Files
qt6-migration-pipeline/external/BuildingModels/StaticMeshes/bldg_1103.flt.xml
T
2026-10-23 16:13:31 +00:00

1157 lines
60 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Tue Oct 12 10:02:41 2021 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_1103</Name>
<ModelId Id="1103"></ModelId>
<BBox_Min Z="-0.250" Y="-1.140" X="-1.140"></BBox_Min>
<BBox_Max Z="6.706" Y="7.166" X="18.995"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.000" X="0.000"></BBox_Min>
<BBox_Max Z="0.000" Y="6.026" X="17.855"></BBox_Max>
<Polygon>
<Name>p5305</Name>
<Vertex>
<Name>p5305/V1</Name>
<Coord X="17.855" Y="6.026" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5305/V2</Name>
<Coord X="0.000" Y="6.026" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5305/V3</Name>
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5305/V4</Name>
<Coord X="17.855" Y="0.000" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0.00</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.250" Y="-0.098" X="-0.098"></BBox_Min>
<BBox_Max Z="2.710" Y="6.152" X="6.211"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="0.000" Y="5.846" X="6.031"></BBox_Max>
<Polygon>
<Name>p5381</Name>
<Vertex>
<Name>p5381/V1</Name>
<Coord X="0.180" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5381/V2</Name>
<Coord X="6.031" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5381/V3</Name>
<Coord X="6.031" Y="5.846" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5381/V4</Name>
<Coord X="0.180" Y="5.846" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0017</Name>
<SubId ID="11017"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.917" Y="6.114" X="1.404"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0018</Name>
<SubId ID="11018"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.215" Y="6.203" X="4.856"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.23" Y="1.854" X="-0.18"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.218" Y="4.513" X="-0.174"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0005</Name>
<SubId ID="11005"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.228" Y="-0.217" X="1.771"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0006</Name>
<SubId ID="11006"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.219" Y="-0.222" X="4.582"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.013" X="3.105"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="1.992" Y="0.180" X="0.872"></Coord>
<Dir Z="0.000" Y="1.000" X="-0.017"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_102</Name>
<SubId ID="2102"></SubId>
<Group>
<Name>undest_room_102</Name>
<BBox_Min Z="-0.250" Y="1.672" X="6.031"></BBox_Min>
<BBox_Max Z="2.710" Y="6.026" X="9.186"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="1.852" X="6.211"></BBox_Min>
<BBox_Max Z="0.000" Y="5.986" X="8.808"></BBox_Max>
<Polygon>
<Name>p5382</Name>
<Vertex>
<Name>p5382/V1</Name>
<Coord X="8.808" Y="5.846" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5382/V2</Name>
<Coord X="7.808" Y="5.846" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5382/V3</Name>
<Coord X="7.808" Y="5.986" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5382/V4</Name>
<Coord X="6.672" Y="5.986" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5382/V5</Name>
<Coord X="6.672" Y="5.846" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5382/V6</Name>
<Coord X="6.211" Y="5.846" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5382/V7</Name>
<Coord X="6.211" Y="1.852" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5382/V8</Name>
<Coord X="8.808" Y="1.852" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0019</Name>
<SubId ID="11019"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.345" Y="6.122" X="7.076"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.849" X="7.509"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_2</Name>
<SubId ID="14002"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.191" Y="5.846" X="8.178"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.017"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_103</Name>
<SubId ID="2103"></SubId>
<Group>
<Name>undest_room_103</Name>
<BBox_Min Z="-0.250" Y="0.000" X="8.808"></BBox_Min>
<BBox_Max Z="3.834" Y="6.026" X="11.819"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.040" X="8.988"></BBox_Min>
<BBox_Max Z="0.000" Y="5.846" X="11.639"></BBox_Max>
<Polygon>
<Name>p5383</Name>
<Vertex>
<Name>p5383/V1</Name>
<Coord X="11.639" Y="5.846" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5383/V2</Name>
<Coord X="8.988" Y="5.846" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5383/V3</Name>
<Coord X="8.988" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5383/V4</Name>
<Coord X="9.967" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5383/V5</Name>
<Coord X="9.967" Y="0.040" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5383/V6</Name>
<Coord X="11.103" Y="0.040" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5383/V7</Name>
<Coord X="11.103" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5383/V8</Name>
<Coord X="11.639" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0020</Name>
<SubId ID="11020"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.344" Y="6.122" X="10.475"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_3</Name>
<SubId ID="16003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.562" X="10.424"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_4</Name>
<SubId ID="16004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="1.570" Y="5.335" X="10.314"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_3</Name>
<SubId ID="14003"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.275" Y="0.180" X="11.335"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_104</Name>
<SubId ID="2104"></SubId>
<Group>
<Name>undest_room_104</Name>
<BBox_Min Z="-0.250" Y="1.690" X="11.441"></BBox_Min>
<BBox_Max Z="2.710" Y="6.125" X="14.839"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="1.870" X="11.819"></BBox_Min>
<BBox_Max Z="0.000" Y="5.846" X="14.659"></BBox_Max>
<Polygon>
<Name>p5384</Name>
<Vertex>
<Name>p5384/V1</Name>
<Coord X="11.819" Y="5.846" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5384/V2</Name>
<Coord X="11.819" Y="1.870" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5384/V3</Name>
<Coord X="14.659" Y="1.870" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5384/V4</Name>
<Coord X="14.659" Y="5.846" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0021</Name>
<SubId ID="11021"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.231" Y="6.198" X="13.307"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_5</Name>
<SubId ID="16005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.858" X="13.239"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_4</Name>
<SubId ID="14004"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.193" Y="5.549" X="14.659"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_105</Name>
<SubId ID="2105"></SubId>
<Group>
<Name>undest_room_105</Name>
<BBox_Min Z="-0.250" Y="-0.098" X="14.659"></BBox_Min>
<BBox_Max Z="2.710" Y="6.152" X="17.953"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="14.839"></BBox_Min>
<BBox_Max Z="0.000" Y="5.846" X="17.675"></BBox_Max>
<Polygon>
<Name>p5386</Name>
<Vertex>
<Name>p5386/V1</Name>
<Coord X="14.839" Y="5.846" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5386/V2</Name>
<Coord X="14.839" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5386/V3</Name>
<Coord X="17.675" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5386/V4</Name>
<Coord X="17.675" Y="5.846" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0022</Name>
<SubId ID="11022"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.233" Y="6.197" X="16.13"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0010</Name>
<SubId ID="11010"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.222" Y="-0.212" X="16.095"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0029</Name>
<SubId ID="11029"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.231" Y="1.452" X="18.076999999999998"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_6</Name>
<SubId ID="16006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.013" X="16.257"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_5</Name>
<SubId ID="14005"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.185" Y="5.549" X="17.675"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_106</Name>
<SubId ID="2106"></SubId>
<Group>
<Name>undest_room_106</Name>
<BBox_Min Z="-0.250" Y="-0.098" X="11.639"></BBox_Min>
<BBox_Max Z="2.710" Y="1.870" X="14.839"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="11.819"></BBox_Min>
<BBox_Max Z="0.000" Y="1.690" X="14.659"></BBox_Max>
<Polygon>
<Name>p5385</Name>
<Vertex>
<Name>p5385/V1</Name>
<Coord X="14.659" Y="1.690" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5385/V2</Name>
<Coord X="11.819" Y="1.690" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5385/V3</Name>
<Coord X="11.819" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5385/V4</Name>
<Coord X="14.659" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0009</Name>
<SubId ID="11009"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.225" Y="-0.22999999999999998" X="13.031"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_7</Name>
<SubId ID="16007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="0.935" X="13.239"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_6</Name>
<SubId ID="14006"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.275" Y="0.354" X="14.659"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_107</Name>
<SubId ID="2107"></SubId>
<Group>
<Name>undest_room_107</Name>
<BBox_Min Z="-0.250" Y="-0.098" X="6.031"></BBox_Min>
<BBox_Max Z="2.710" Y="1.852" X="8.988"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="6.211"></BBox_Min>
<BBox_Max Z="0.000" Y="1.672" X="8.808"></BBox_Max>
<Polygon>
<Name>p5387</Name>
<Vertex>
<Name>p5387/V1</Name>
<Coord X="8.808" Y="1.672" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5387/V2</Name>
<Coord X="6.211" Y="1.672" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5387/V3</Name>
<Coord X="6.211" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p5387/V4</Name>
<Coord X="8.808" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0007</Name>
<SubId ID="11007"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.228" Y="-0.221" X="7.415"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_8</Name>
<SubId ID="16008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="0.926" X="7.509"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_7</Name>
<SubId ID="14007"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.275" Y="0.351" X="6.211"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=2.71</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.510" Y="0.000" X="0.000"></BBox_Min>
<BBox_Max Z="5.589" Y="6.376" X="3.205"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.710" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="2.710" Y="5.846" X="3.025"></BBox_Max>
<Polygon>
<Name>p5413</Name>
<Vertex>
<Name>p5413/V1</Name>
<Coord X="3.025" Y="5.846" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5413/V2</Name>
<Coord X="0.180" Y="5.846" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5413/V3</Name>
<Coord X="0.180" Y="0.180" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5413/V4</Name>
<Coord X="3.025" Y="0.180" Z="2.710"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0023</Name>
<SubId ID="11023"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.456" Y="6.11" X="1.713"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0004</Name>
<SubId ID="11004"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.439" Y="1.444" X="-0.101"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0003</Name>
<SubId ID="11003"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.454" Y="4.093" X="-0.094"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0011</Name>
<SubId ID="11011"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.444" Y="-0.136" X="1.882"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_9</Name>
<SubId ID="16009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.010" Y="3.013" X="1.603"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_8</Name>
<SubId ID="14008"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.987" Y="0.398" X="0.180"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_202</Name>
<SubId ID="2202"></SubId>
<Group>
<Name>undest_room_202</Name>
<BBox_Min Z="2.510" Y="1.671" X="3.025"></BBox_Min>
<BBox_Max Z="5.857" Y="6.227" X="6.211"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.710" Y="1.852" X="3.205"></BBox_Min>
<BBox_Max Z="2.710" Y="5.846" X="6.031"></BBox_Max>
<Polygon>
<Name>p5414</Name>
<Vertex>
<Name>p5414/V1</Name>
<Coord X="6.031" Y="5.846" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5414/V2</Name>
<Coord X="3.205" Y="5.846" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5414/V3</Name>
<Coord X="3.205" Y="1.852" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5414/V4</Name>
<Coord X="6.031" Y="1.852" Z="2.710"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0024</Name>
<SubId ID="11024"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.754" Y="6.109" X="4.739"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_10</Name>
<SubId ID="16010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.010" Y="3.849" X="4.618"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_9</Name>
<SubId ID="14009"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.987" Y="5.846" X="5.714"></Coord>
<Dir Z="-0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_203</Name>
<SubId ID="2203"></SubId>
<Group>
<Name>undest_room_203</Name>
<BBox_Min Z="2.510" Y="1.669" X="6.031"></BBox_Min>
<BBox_Max Z="5.540" Y="6.227" X="8.988"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.710" Y="1.852" X="6.211"></BBox_Min>
<BBox_Max Z="2.710" Y="5.846" X="8.808"></BBox_Max>
<Polygon>
<Name>p5415</Name>
<Vertex>
<Name>p5415/V1</Name>
<Coord X="8.808" Y="5.846" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5415/V2</Name>
<Coord X="6.211" Y="5.846" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5415/V3</Name>
<Coord X="6.211" Y="1.852" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5415/V4</Name>
<Coord X="8.808" Y="1.852" Z="2.710"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0025</Name>
<SubId ID="11025"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.46" Y="6.1080000000000005" X="7.423"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_11</Name>
<SubId ID="16011"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.010" Y="3.849" X="7.509"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_10</Name>
<SubId ID="14010"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.987" Y="5.646" X="8.808"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_204</Name>
<SubId ID="2204"></SubId>
<Group>
<Name>undest_room_204</Name>
<BBox_Min Z="2.510" Y="0.000" X="8.808"></BBox_Min>
<BBox_Max Z="5.589" Y="6.227" X="11.819"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.710" Y="0.180" X="8.988"></BBox_Min>
<BBox_Max Z="2.710" Y="5.846" X="11.639"></BBox_Max>
<Polygon>
<Name>p5416</Name>
<Vertex>
<Name>p5416/V1</Name>
<Coord X="8.988" Y="5.846" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5416/V2</Name>
<Coord X="8.988" Y="0.180" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5416/V3</Name>
<Coord X="11.639" Y="0.180" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5416/V4</Name>
<Coord X="11.639" Y="5.846" Z="2.710"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>subroom_1</Name>
<BBox_Min Z="2.710" Y="0.180" X="8.988"></BBox_Min>
<BBox_Max Z="2.710" Y="2.604" X="11.639"></BBox_Max>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0026</Name>
<SubId ID="11026"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.548" Y="6.109" X="10.476"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0014</Name>
<SubId ID="11014"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.45" Y="-0.138" X="10.37"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0008</Name>
<SubId ID="11008"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.724" Y="-0.136" X="11.054"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_12</Name>
<SubId ID="16012"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.010" Y="1.392" X="10.315"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_11</Name>
<SubId ID="14011"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.987" Y="0.180" X="9.532"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_205</Name>
<SubId ID="2205"></SubId>
<Group>
<Name>undest_room_205</Name>
<BBox_Min Z="2.510" Y="1.690" X="11.639"></BBox_Min>
<BBox_Max Z="5.540" Y="6.227" X="14.839"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.710" Y="1.870" X="11.819"></BBox_Min>
<BBox_Max Z="2.710" Y="5.846" X="14.659"></BBox_Max>
<Polygon>
<Name>p5417</Name>
<Vertex>
<Name>p5417/V1</Name>
<Coord X="11.819" Y="5.846" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5417/V2</Name>
<Coord X="11.819" Y="1.870" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5417/V3</Name>
<Coord X="14.659" Y="1.870" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5417/V4</Name>
<Coord X="14.659" Y="5.846" Z="2.710"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0027</Name>
<SubId ID="11027"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.456" Y="6.1080000000000005" X="13.198"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_13</Name>
<SubId ID="16013"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.010" Y="3.858" X="13.239"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_12</Name>
<SubId ID="14012"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="5.062" Y="5.447" X="14.659"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_206</Name>
<SubId ID="2206"></SubId>
<Group>
<Name>undest_room_206</Name>
<BBox_Min Z="2.510" Y="0.000" X="14.659"></BBox_Min>
<BBox_Max Z="5.589" Y="6.376" X="17.855"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.710" Y="0.180" X="14.839"></BBox_Min>
<BBox_Max Z="2.710" Y="5.846" X="17.675"></BBox_Max>
<Polygon>
<Name>p5418</Name>
<Vertex>
<Name>p5418/V1</Name>
<Coord X="14.839" Y="5.846" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5418/V2</Name>
<Coord X="14.839" Y="0.180" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5418/V3</Name>
<Coord X="17.675" Y="0.180" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5418/V4</Name>
<Coord X="17.675" Y="5.846" Z="2.710"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0028</Name>
<SubId ID="11028"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.453" Y="6.107" X="16.016"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0016</Name>
<SubId ID="11016"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.454" Y="-0.137" X="16.196"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0030</Name>
<SubId ID="11030"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.451" Y="1.85" X="17.980999999999998"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_14</Name>
<SubId ID="16014"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.010" Y="3.013" X="16.257"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_13</Name>
<SubId ID="14013"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.987" Y="5.846" X="17.316"></Coord>
<Dir Z="-0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_207</Name>
<SubId ID="2207"></SubId>
<Group>
<Name>undest_room_207</Name>
<BBox_Min Z="2.510" Y="0.000" X="11.639"></BBox_Min>
<BBox_Max Z="5.589" Y="1.870" X="14.839"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.710" Y="0.180" X="11.819"></BBox_Min>
<BBox_Max Z="2.710" Y="1.690" X="14.659"></BBox_Max>
<Polygon>
<Name>p5419</Name>
<Vertex>
<Name>p5419/V1</Name>
<Coord X="14.659" Y="1.690" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5419/V2</Name>
<Coord X="11.819" Y="1.690" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5419/V3</Name>
<Coord X="11.819" Y="0.180" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5419/V4</Name>
<Coord X="14.659" Y="0.180" Z="2.710"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0015</Name>
<SubId ID="11015"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.449" Y="-0.132" X="13.469"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_15</Name>
<SubId ID="16015"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.010" Y="0.935" X="13.239"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_14</Name>
<SubId ID="14014"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="5.174" Y="0.857" X="14.659"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_208</Name>
<SubId ID="2208"></SubId>
<Group>
<Name>undest_room_208</Name>
<BBox_Min Z="2.510" Y="0.000" X="3.025"></BBox_Min>
<BBox_Max Z="5.589" Y="1.852" X="8.988"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.710" Y="0.180" X="3.205"></BBox_Min>
<BBox_Max Z="2.710" Y="1.672" X="8.808"></BBox_Max>
<Polygon>
<Name>p5420</Name>
<Vertex>
<Name>p5420/V1</Name>
<Coord X="8.808" Y="1.672" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5420/V2</Name>
<Coord X="3.205" Y="1.672" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5420/V3</Name>
<Coord X="3.205" Y="0.180" Z="2.710"></Coord>
</Vertex>
<Vertex>
<Name>p5420/V4</Name>
<Coord X="8.808" Y="0.180" Z="2.710"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0012</Name>
<SubId ID="11012"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.447" Y="-0.135" X="5.001"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0013</Name>
<SubId ID="11013"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.452" Y="-0.133" X="7.834"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_16</Name>
<SubId ID="16016"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.010" Y="0.926" X="6.007"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_15</Name>
<SubId ID="14015"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.987" Y="0.398" X="3.205"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_3</Name>
<Comment>base_height=5.5</Comment>
<Switch>
<Name>SW_room_301</Name>
<SubId ID="2301"></SubId>
<Group>
<Name>undest_room_301</Name>
<BBox_Min Z="5.201" Y="0.000" X="0.000"></BBox_Min>
<BBox_Max Z="6.706" Y="6.405" X="17.855"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="5.500" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="5.500" Y="6.227" X="17.675"></BBox_Max>
<Polygon>
<Name>p5424</Name>
<Vertex>
<Name>p5424/V1</Name>
<Coord X="0.180" Y="6.227" Z="5.500"></Coord>
</Vertex>
<Vertex>
<Name>p5424/V2</Name>
<Coord X="0.180" Y="0.180" Z="5.500"></Coord>
</Vertex>
<Vertex>
<Name>p5424/V3</Name>
<Coord X="17.675" Y="0.180" Z="5.500"></Coord>
</Vertex>
<Vertex>
<Name>p5424/V4</Name>
<Coord X="17.675" Y="6.227" Z="5.500"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>subroom_2</Name>
<BBox_Min Z="5.406" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="5.584" Y="6.227" X="17.675"></BBox_Max>
</Group>
<External_Reference>
<Name>IPS_IN_AP_17</Name>
<SubId ID="16017"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="5.800" Y="3.203" X="8.928"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="2.260" Y="-0.100" X="0.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="1.500" X="-1.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="4.500" X="-1.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="7.070" X="2.500"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="7.079" X="6.785"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_5</Name>
<SubId ID="15005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="7.088" X="11.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_6</Name>
<SubId ID="15006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="7.096" X="15.355"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_7</Name>
<SubId ID="15007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="4.526" X="18.925"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_8</Name>
<SubId ID="15008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="1.526" X="18.925"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_9</Name>
<SubId ID="15009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.044" X="15.355"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_10</Name>
<SubId ID="15010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.052" X="11.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_11</Name>
<SubId ID="15011"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.061" X="6.785"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_12</Name>
<SubId ID="15012"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.070" X="2.500"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="3.321" Y="2.444" X="6.374"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_2</Name>
<SubId ID="27002"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.740" Y="2.782" X="8.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>