Files
qt6-migration-pipeline/external/BuildingModels/StaticMeshes/bldg_1222.flt.xml
T
2026-10-23 16:13:31 +00:00

710 lines
37 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Thu Nov 11 15:06:46 2021 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_1222</Name>
<ModelId Id="1222"></ModelId>
<BBox_Min Z="-0.200" Y="-1.140" X="-1.140"></BBox_Min>
<BBox_Max Z="6.950" Y="7.140" X="13.140"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.000" X="-0.000"></BBox_Min>
<BBox_Max Z="0.000" Y="6.007" X="12.120"></BBox_Max>
<Polygon>
<Name>p3817</Name>
<Vertex>
<Name>p3817/V1</Name>
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3817/V2</Name>
<Coord X="12.120" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3817/V3</Name>
<Coord X="12.120" Y="6.007" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3817/V4</Name>
<Coord X="-0.000" Y="6.007" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0.00</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.200" Y="-0.079" X="-0.000"></BBox_Min>
<BBox_Max Z="3.797" Y="2.997" X="6.247"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.183" X="0.177"></BBox_Min>
<BBox_Max Z="0.000" Y="2.806" X="6.067"></BBox_Max>
<Polygon>
<Name>p3823</Name>
<Vertex>
<Name>p3823/V1</Name>
<Coord X="0.177" Y="0.183" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3823/V2</Name>
<Coord X="6.067" Y="0.183" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3823/V3</Name>
<Coord X="6.067" Y="2.806" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3823/V4</Name>
<Coord X="0.177" Y="2.806" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0013</Name>
<SubId ID="11013"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.373" Y="-0.109" X="4.986"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0012</Name>
<SubId ID="11012"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.11" Y="-0.189" X="3.092"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0009</Name>
<SubId ID="11009"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.315" Y="1.556" X="-0.139"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="3.367" Y="1.496" X="0.177"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="1.560" Y="1.495" X="0.662"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.495" X="3.122"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_102</Name>
<SubId ID="2102"></SubId>
<Group>
<Name>undest_room_102</Name>
<BBox_Min Z="-0.200" Y="2.806" X="-0.000"></BBox_Min>
<BBox_Max Z="2.690" Y="6.123" X="6.247"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="2.997" X="0.177"></BBox_Min>
<BBox_Max Z="0.000" Y="5.840" X="6.067"></BBox_Max>
<Polygon>
<Name>p3825</Name>
<Vertex>
<Name>p3825/V1</Name>
<Coord X="6.067" Y="5.840" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3825/V2</Name>
<Coord X="0.177" Y="5.840" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3825/V3</Name>
<Coord X="0.177" Y="2.997" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3825/V4</Name>
<Coord X="6.067" Y="2.997" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0003</Name>
<SubId ID="11003"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.021" Y="6.208" X="2.001"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0008</Name>
<SubId ID="11008"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.949" Y="4.361" X="-0.138"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_3</Name>
<SubId ID="16003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.419" X="3.122"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_2</Name>
<SubId ID="14002"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.282" Y="5.493" X="6.067"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_103</Name>
<SubId ID="2103"></SubId>
<Group>
<Name>undest_room_103</Name>
<BBox_Min Z="-0.200" Y="-0.079" X="6.067"></BBox_Min>
<BBox_Max Z="2.690" Y="6.084" X="9.254"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.183" X="6.247"></BBox_Min>
<BBox_Max Z="0.000" Y="5.840" X="9.074"></BBox_Max>
<Polygon>
<Name>p3826</Name>
<Vertex>
<Name>p3826/V1</Name>
<Coord X="6.247" Y="5.840" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3826/V2</Name>
<Coord X="6.247" Y="0.183" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3826/V3</Name>
<Coord X="9.074" Y="0.183" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3826/V4</Name>
<Coord X="9.074" Y="5.840" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0014</Name>
<SubId ID="11014"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.116" Y="-0.184" X="7.333"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.029" Y="6.2090000000000005" X="7.915"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_4</Name>
<SubId ID="16004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.012" X="7.660"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_3</Name>
<SubId ID="14003"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.282" Y="5.840" X="6.658"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_104</Name>
<SubId ID="2104"></SubId>
<Group>
<Name>undest_room_104</Name>
<BBox_Min Z="-0.200" Y="-0.079" X="9.074"></BBox_Min>
<BBox_Max Z="2.690" Y="6.123" X="12.120"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.183" X="9.254"></BBox_Min>
<BBox_Max Z="0.000" Y="5.840" X="12.030"></BBox_Max>
<Polygon>
<Name>p3827</Name>
<Vertex>
<Name>p3827/V1</Name>
<Coord X="9.254" Y="5.840" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3827/V2</Name>
<Coord X="9.254" Y="0.183" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3827/V3</Name>
<Coord X="12.030" Y="0.183" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p3827/V4</Name>
<Coord X="12.030" Y="5.840" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0015</Name>
<SubId ID="11015"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.114" Y="-0.186" X="10.049"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.301" Y="6.132000000000001" X="10.013"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_5</Name>
<SubId ID="16005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.012" X="10.642"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_4</Name>
<SubId ID="14004"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.282" Y="0.183" X="11.593"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=2.69</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.490" Y="-0.000" X="-0.000"></BBox_Min>
<BBox_Max Z="5.568" Y="2.999" X="6.247"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.690" Y="0.183" X="0.177"></BBox_Min>
<BBox_Max Z="2.690" Y="2.806" X="6.067"></BBox_Max>
<Polygon>
<Name>p3834</Name>
<Vertex>
<Name>p3834/V1</Name>
<Coord X="6.067" Y="2.806" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p3834/V2</Name>
<Coord X="0.177" Y="2.806" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p3834/V3</Name>
<Coord X="0.177" Y="0.183" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p3834/V4</Name>
<Coord X="6.067" Y="0.183" Z="2.690"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>subroom_1</Name>
<BBox_Min Z="2.690" Y="1.808" X="3.361"></BBox_Min>
<BBox_Max Z="2.690" Y="2.806" X="6.067"></BBox_Max>
</Group>
<Group>
<Name>subroom_2</Name>
<BBox_Min Z="2.690" Y="0.183" X="3.470"></BBox_Min>
<BBox_Max Z="2.690" Y="1.808" X="6.067"></BBox_Max>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0017</Name>
<SubId ID="11017"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.494" Y="-0.107" X="5.217"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0016</Name>
<SubId ID="11016"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.487" Y="-0.115" X="3.357"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0011</Name>
<SubId ID="11011"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.755" Y="1.552" X="-0.14300000000000002"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_6</Name>
<SubId ID="16006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="2.990" Y="1.495" X="4.714"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_5</Name>
<SubId ID="14005"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="5.092" Y="2.526" X="6.067"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_202</Name>
<SubId ID="2202"></SubId>
<Group>
<Name>undest_room_202</Name>
<BBox_Min Z="2.490" Y="2.805" X="-0.000"></BBox_Min>
<BBox_Max Z="5.494" Y="6.349" X="6.247"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.690" Y="2.997" X="0.177"></BBox_Min>
<BBox_Max Z="2.690" Y="5.840" X="6.067"></BBox_Max>
<Polygon>
<Name>p3838</Name>
<Vertex>
<Name>p3838/V1</Name>
<Coord X="0.177" Y="2.997" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p3838/V2</Name>
<Coord X="6.067" Y="2.997" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p3838/V3</Name>
<Coord X="6.067" Y="5.840" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p3838/V4</Name>
<Coord X="0.177" Y="5.840" Z="2.690"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0007</Name>
<SubId ID="11007"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.364" Y="6.132000000000001" X="1.705"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0006</Name>
<SubId ID="11006"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.392" Y="6.135000000000001" X="4.696"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0010</Name>
<SubId ID="11010"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.513" Y="4.254" X="-0.138"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_7</Name>
<SubId ID="16007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="2.990" Y="4.419" X="3.122"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_6</Name>
<SubId ID="14006"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.849" Y="3.497" X="0.177"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_203</Name>
<SubId ID="2203"></SubId>
<Group>
<Name>undest_room_203</Name>
<BBox_Min Z="2.490" Y="-0.000" X="6.067"></BBox_Min>
<BBox_Max Z="5.854" Y="6.227" X="9.254"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.690" Y="0.183" X="6.247"></BBox_Min>
<BBox_Max Z="2.690" Y="5.840" X="9.074"></BBox_Max>
<Polygon>
<Name>p3839</Name>
<Vertex>
<Name>p3839/V1</Name>
<Coord X="6.247" Y="0.183" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p3839/V2</Name>
<Coord X="9.074" Y="0.183" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p3839/V3</Name>
<Coord X="9.074" Y="5.840" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p3839/V4</Name>
<Coord X="6.247" Y="5.840" Z="2.690"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0018</Name>
<SubId ID="11018"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.476" Y="-0.114" X="7.61"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0005</Name>
<SubId ID="11005"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.384" Y="6.135000000000001" X="7.639"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_8</Name>
<SubId ID="16008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="2.990" Y="3.012" X="7.660"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_7</Name>
<SubId ID="14007"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.965" Y="0.183" X="8.637"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_204</Name>
<SubId ID="2204"></SubId>
<Group>
<Name>undest_room_204</Name>
<BBox_Min Z="2.490" Y="-0.000" X="9.074"></BBox_Min>
<BBox_Max Z="5.578" Y="6.349" X="12.120"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.690" Y="0.183" X="9.254"></BBox_Min>
<BBox_Max Z="2.690" Y="5.840" X="12.030"></BBox_Max>
<Polygon>
<Name>p3840</Name>
<Vertex>
<Name>p3840/V1</Name>
<Coord X="9.254" Y="5.840" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p3840/V2</Name>
<Coord X="9.254" Y="0.183" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p3840/V3</Name>
<Coord X="12.030" Y="0.183" Z="2.690"></Coord>
</Vertex>
<Vertex>
<Name>p3840/V4</Name>
<Coord X="12.030" Y="5.840" Z="2.690"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0019</Name>
<SubId ID="11019"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.499" Y="-0.124" X="10.309"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0004</Name>
<SubId ID="11004"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.383" Y="6.132000000000001" X="10.318"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_9</Name>
<SubId ID="16009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="2.990" Y="3.012" X="10.642"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_8</Name>
<SubId ID="14008"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.965" Y="0.183" X="11.640"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_3</Name>
<Comment>base_height=5.482</Comment>
<Switch>
<Name>SW_room_301</Name>
<SubId ID="2301"></SubId>
<Group>
<Name>undest_room_301</Name>
<BBox_Min Z="5.176" Y="-0.000" X="-0.000"></BBox_Min>
<BBox_Max Z="6.950" Y="6.387" X="12.120"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="5.482" Y="0.183" X="0.177"></BBox_Min>
<BBox_Max Z="5.482" Y="6.227" X="12.030"></BBox_Max>
<Polygon>
<Name>p3854</Name>
<Vertex>
<Name>p3854/V1</Name>
<Coord X="12.030" Y="0.183" Z="5.482"></Coord>
</Vertex>
<Vertex>
<Name>p3854/V2</Name>
<Coord X="12.030" Y="6.227" Z="5.482"></Coord>
</Vertex>
<Vertex>
<Name>p3854/V3</Name>
<Coord X="0.177" Y="6.227" Z="5.482"></Coord>
</Vertex>
<Vertex>
<Name>p3854/V4</Name>
<Coord X="0.177" Y="0.183" Z="5.482"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>subroom_3</Name>
<BBox_Min Z="5.397" Y="0.183" X="0.177"></BBox_Min>
<BBox_Max Z="5.578" Y="6.227" X="12.030"></BBox_Max>
</Group>
<External_Reference>
<Name>IPS_IN_AP_10</Name>
<SubId ID="16010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="6.082" Y="3.205" X="6.104"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="2.440" Y="0.100" X="-0.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="4.500" X="13.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="1.500" X="13.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.070" X="9.600"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.070" X="6.000"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_5</Name>
<SubId ID="15005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="-1.070" X="2.400"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_6</Name>
<SubId ID="15006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="1.500" X="-1.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_7</Name>
<SubId ID="15007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="4.500" X="-1.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_8</Name>
<SubId ID="15008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="7.070" X="2.400"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_9</Name>
<SubId ID="15009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="7.070" X="6.000"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_10</Name>
<SubId ID="15010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.374" Y="7.070" X="9.600"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.600" Y="1.708" X="3.034"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_2</Name>
<SubId ID="27002"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="3.271" Y="2.943" X="6.347"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>