1104 lines
57 KiB
XML
Executable File
1104 lines
57 KiB
XML
Executable File
<?xml version="1.0" ?>
|
|
<!--fltHdrLastDate Wed Dec 01 17:11:43 2021 - PostProcessed by SLTE $Rev: 56086 $-->
|
|
<STREIF>
|
|
<Header>
|
|
<Group>
|
|
<Name>bldg_3222</Name>
|
|
<ModelId Id="1222"></ModelId>
|
|
<BBox_Min Z="-0.300" Y="-1.140" X="-1.140"></BBox_Min>
|
|
<BBox_Max Z="11.332" Y="7.140" X="19.140"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="0.000" X="0.000"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="6.000" X="17.950"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9389</Name>
|
|
<Vertex>
|
|
<Name>p9389/V1</Name>
|
|
<Coord X="17.950" Y="6.000" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9389/V2</Name>
|
|
<Coord X="0.000" Y="6.000" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9389/V3</Name>
|
|
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9389/V4</Name>
|
|
<Coord X="17.950" Y="0.000" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<Group>
|
|
<Name>floor_1</Name>
|
|
<Comment>base_height=0.00</Comment>
|
|
<Switch>
|
|
<Name>SW_room_101</Name>
|
|
<SubId ID="2101"></SubId>
|
|
<Group>
|
|
<Name>undest_room_101</Name>
|
|
<BBox_Min Z="-0.300" Y="-0.151" X="0.000"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="6.156" X="4.624"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="0.180" X="0.090"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="5.820" X="3.618"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9384</Name>
|
|
<Vertex>
|
|
<Name>p9384/V1</Name>
|
|
<Coord X="3.618" Y="5.820" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9384/V2</Name>
|
|
<Coord X="0.090" Y="5.820" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9384/V3</Name>
|
|
<Coord X="0.090" Y="0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9384/V4</Name>
|
|
<Coord X="3.618" Y="0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0012</Name>
|
|
<SubId ID="11012"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.154" Y="-0.199" X="2.272"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0004</Name>
|
|
<SubId ID="11004"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="1.894" Y="6.107" X="1.766"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_1</Name>
|
|
<SubId ID="14001"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.325" Y="0.180" X="1.126"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_1</Name>
|
|
<SubId ID="16001"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="2.965" X="1.835"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_102</Name>
|
|
<SubId ID="2102"></SubId>
|
|
<Group>
|
|
<Name>undest_room_102</Name>
|
|
<BBox_Min Z="-0.300" Y="0.000" X="3.618"></BBox_Min>
|
|
<BBox_Max Z="2.926" Y="6.000" X="7.827"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="0.180" X="3.798"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="5.820" X="7.647"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9385</Name>
|
|
<Vertex>
|
|
<Name>p9385/V1</Name>
|
|
<Coord X="7.647" Y="5.820" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9385/V2</Name>
|
|
<Coord X="3.798" Y="5.820" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9385/V3</Name>
|
|
<Coord X="3.798" Y="0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9385/V4</Name>
|
|
<Coord X="7.647" Y="0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0013</Name>
|
|
<SubId ID="11013"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.404" Y="-0.123" X="6.244"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0003</Name>
|
|
<SubId ID="11003"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.273" Y="6.105" X="5.694"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_2</Name>
|
|
<SubId ID="14002"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.325" Y="0.180" X="5.685"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_2</Name>
|
|
<SubId ID="16002"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="1.878" X="5.739"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_103</Name>
|
|
<SubId ID="2103"></SubId>
|
|
<Group>
|
|
<Name>undest_room_103</Name>
|
|
<BBox_Min Z="-0.300" Y="2.576" X="7.437"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="6.075" X="10.445"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="2.756" X="7.827"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="5.820" X="10.265"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9386</Name>
|
|
<Vertex>
|
|
<Name>p9386/V1</Name>
|
|
<Coord X="10.265" Y="5.820" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9386/V2</Name>
|
|
<Coord X="7.827" Y="5.820" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9386/V3</Name>
|
|
<Coord X="7.827" Y="2.756" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9386/V4</Name>
|
|
<Coord X="10.265" Y="2.756" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0002</Name>
|
|
<SubId ID="11002"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.047" Y="6.180000000000001" X="8.865"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_3</Name>
|
|
<SubId ID="14003"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.209" Y="5.820" X="9.815"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_3</Name>
|
|
<SubId ID="16003"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="4.260" X="9.120"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_104</Name>
|
|
<SubId ID="2104"></SubId>
|
|
<Group>
|
|
<Name>undest_room_104</Name>
|
|
<BBox_Min Z="-0.300" Y="0.000" X="7.647"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="2.756" X="10.445"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="0.180" X="7.827"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="2.576" X="10.265"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9387</Name>
|
|
<Vertex>
|
|
<Name>p9387/V1</Name>
|
|
<Coord X="10.265" Y="2.576" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9387/V2</Name>
|
|
<Coord X="7.827" Y="2.576" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9387/V3</Name>
|
|
<Coord X="7.827" Y="0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9387/V4</Name>
|
|
<Coord X="10.265" Y="0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0014</Name>
|
|
<SubId ID="11014"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.445" Y="-0.12" X="9.623"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_4</Name>
|
|
<SubId ID="16004"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="1.445" X="9.061"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_105</Name>
|
|
<SubId ID="2105"></SubId>
|
|
<Group>
|
|
<Name>undest_room_105</Name>
|
|
<BBox_Min Z="-0.300" Y="-0.151" X="10.265"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="6.156" X="17.950"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="0.000" Y="0.180" X="10.445"></BBox_Min>
|
|
<BBox_Max Z="0.000" Y="5.820" X="17.860"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9388</Name>
|
|
<Vertex>
|
|
<Name>p9388/V1</Name>
|
|
<Coord X="17.860" Y="5.820" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9388/V2</Name>
|
|
<Coord X="10.445" Y="5.820" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9388/V3</Name>
|
|
<Coord X="10.445" Y="0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9388/V4</Name>
|
|
<Coord X="17.860" Y="0.180" Z="0.000"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0015</Name>
|
|
<SubId ID="11015"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.165" Y="-0.19" X="14.344"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0001</Name>
|
|
<SubId ID="11001"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="2.051" Y="6.175000000000001" X="14.903"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_4</Name>
|
|
<SubId ID="14004"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="2.209" Y="2.856" X="17.860"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_5</Name>
|
|
<SubId ID="16005"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="2.940" X="14.021"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
</Group>
|
|
<Group>
|
|
<Name>floor_2</Name>
|
|
<Comment>base_height=2.7</Comment>
|
|
<Switch>
|
|
<Name>SW_room_201</Name>
|
|
<SubId ID="2201"></SubId>
|
|
<Group>
|
|
<Name>undest_room_201</Name>
|
|
<BBox_Min Z="2.500" Y="-0.151" X="0.000"></BBox_Min>
|
|
<BBox_Max Z="5.400" Y="6.156" X="3.798"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="2.700" Y="0.180" X="0.090"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="5.820" X="3.618"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9023</Name>
|
|
<Vertex>
|
|
<Name>p9023/V1</Name>
|
|
<Coord X="0.090" Y="0.180" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9023/V2</Name>
|
|
<Coord X="3.618" Y="0.180" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9023/V3</Name>
|
|
<Coord X="3.618" Y="5.820" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9023/V4</Name>
|
|
<Coord X="0.090" Y="5.820" Z="2.700"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0016</Name>
|
|
<SubId ID="11016"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="3.583" Y="-0.12" X="2.537"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0008</Name>
|
|
<SubId ID="11008"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="4.476" Y="6.1080000000000005" X="1.851"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_5</Name>
|
|
<SubId ID="14005"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="4.909" Y="5.820" X="0.779"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_6</Name>
|
|
<SubId ID="16006"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="3.074" Y="2.904" X="1.868"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_202</Name>
|
|
<SubId ID="2202"></SubId>
|
|
<Group>
|
|
<Name>undest_room_202</Name>
|
|
<BBox_Min Z="1.762" Y="0.000" X="3.618"></BBox_Min>
|
|
<BBox_Max Z="5.626" Y="6.000" X="7.827"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="2.700" Y="0.180" X="3.798"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="5.820" X="7.647"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9024</Name>
|
|
<Vertex>
|
|
<Name>p9024/V1</Name>
|
|
<Coord X="7.647" Y="5.820" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9024/V2</Name>
|
|
<Coord X="3.798" Y="5.820" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9024/V3</Name>
|
|
<Coord X="3.798" Y="0.180" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9024/V4</Name>
|
|
<Coord X="7.647" Y="0.180" Z="2.700"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0017</Name>
|
|
<SubId ID="11017"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="4.594" Y="-0.132" X="6.215"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0007</Name>
|
|
<SubId ID="11007"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="4.492" Y="6.1080000000000005" X="5.723"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_6</Name>
|
|
<SubId ID="14006"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="4.960" Y="0.180" X="4.800"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_7</Name>
|
|
<SubId ID="14007"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="3.534" Y="5.820" X="7.012"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_7</Name>
|
|
<SubId ID="16007"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="3.074" Y="1.581" X="5.739"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_203</Name>
|
|
<SubId ID="2203"></SubId>
|
|
<Group>
|
|
<Name>undest_room_203</Name>
|
|
<BBox_Min Z="2.500" Y="2.576" X="7.647"></BBox_Min>
|
|
<BBox_Max Z="5.400" Y="6.000" X="10.445"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="2.700" Y="2.756" X="7.827"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="5.820" X="10.265"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9025</Name>
|
|
<Vertex>
|
|
<Name>p9025/V1</Name>
|
|
<Coord X="10.265" Y="5.820" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9025/V2</Name>
|
|
<Coord X="7.827" Y="5.820" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9025/V3</Name>
|
|
<Coord X="7.827" Y="2.756" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9025/V4</Name>
|
|
<Coord X="10.265" Y="2.756" Z="2.700"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0006</Name>
|
|
<SubId ID="11006"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="3.51" Y="6.111000000000001" X="8.591"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_8</Name>
|
|
<SubId ID="14008"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="4.909" Y="5.820" X="9.815"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_8</Name>
|
|
<SubId ID="16008"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="3.074" Y="4.248" X="9.105"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_204</Name>
|
|
<SubId ID="2204"></SubId>
|
|
<Group>
|
|
<Name>undest_room_204</Name>
|
|
<BBox_Min Z="2.500" Y="0.000" X="7.647"></BBox_Min>
|
|
<BBox_Max Z="5.400" Y="2.756" X="10.445"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="2.700" Y="0.180" X="7.827"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="2.576" X="10.265"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9026</Name>
|
|
<Vertex>
|
|
<Name>p9026/V1</Name>
|
|
<Coord X="10.265" Y="2.576" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9026/V2</Name>
|
|
<Coord X="7.827" Y="2.576" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9026/V3</Name>
|
|
<Coord X="7.827" Y="0.180" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9026/V4</Name>
|
|
<Coord X="10.265" Y="0.180" Z="2.700"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0018</Name>
|
|
<SubId ID="11018"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="3.629" Y="-0.121" X="9.308"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_9</Name>
|
|
<SubId ID="16009"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="3.074" Y="1.392" X="9.125"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_205</Name>
|
|
<SubId ID="2205"></SubId>
|
|
<Group>
|
|
<Name>undest_room_205</Name>
|
|
<BBox_Min Z="2.500" Y="-0.151" X="10.265"></BBox_Min>
|
|
<BBox_Max Z="5.400" Y="6.156" X="17.950"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="2.700" Y="0.180" X="10.445"></BBox_Min>
|
|
<BBox_Max Z="2.700" Y="5.820" X="17.860"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p9027</Name>
|
|
<Vertex>
|
|
<Name>p9027/V1</Name>
|
|
<Coord X="17.860" Y="5.820" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9027/V2</Name>
|
|
<Coord X="10.445" Y="5.820" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9027/V3</Name>
|
|
<Coord X="10.445" Y="0.180" Z="2.700"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p9027/V4</Name>
|
|
<Coord X="17.860" Y="0.180" Z="2.700"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0019</Name>
|
|
<SubId ID="11019"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="3.586" Y="-0.114" X="14.632"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0005</Name>
|
|
<SubId ID="11005"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="3.523" Y="6.098000000000001" X="14.612"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_9</Name>
|
|
<SubId ID="14009"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="4.909" Y="2.856" X="17.860"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_10</Name>
|
|
<SubId ID="16010"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="3.074" Y="2.993" X="14.045"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
</Group>
|
|
<Group>
|
|
<Name>floor_3</Name>
|
|
<Comment>base_height=5.4</Comment>
|
|
<Switch>
|
|
<Name>SW_room_301</Name>
|
|
<SubId ID="2301"></SubId>
|
|
<Group>
|
|
<Name>undest_room_301</Name>
|
|
<BBox_Min Z="5.200" Y="-0.151" X="0.000"></BBox_Min>
|
|
<BBox_Max Z="8.100" Y="6.156" X="3.798"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="5.400" Y="0.180" X="0.090"></BBox_Min>
|
|
<BBox_Max Z="5.400" Y="5.820" X="3.618"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p8396</Name>
|
|
<Vertex>
|
|
<Name>p8396/V1</Name>
|
|
<Coord X="0.090" Y="0.180" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p8396/V2</Name>
|
|
<Coord X="3.618" Y="0.180" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p8396/V3</Name>
|
|
<Coord X="3.618" Y="5.820" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p8396/V4</Name>
|
|
<Coord X="0.090" Y="5.820" Z="5.400"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0020</Name>
|
|
<SubId ID="11020"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="6.306" Y="-0.123" X="2.565"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_11</Name>
|
|
<SubId ID="16011"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="5.774" Y="2.990" X="1.957"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_10</Name>
|
|
<SubId ID="14010"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="7.609" Y="5.820" X="0.779"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_302</Name>
|
|
<SubId ID="2302"></SubId>
|
|
<Group>
|
|
<Name>undest_room_302</Name>
|
|
<BBox_Min Z="4.462" Y="0.000" X="3.618"></BBox_Min>
|
|
<BBox_Max Z="9.233" Y="6.000" X="7.827"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="5.400" Y="0.180" X="3.798"></BBox_Min>
|
|
<BBox_Max Z="5.400" Y="5.820" X="7.647"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p8397</Name>
|
|
<Vertex>
|
|
<Name>p8397/V1</Name>
|
|
<Coord X="7.647" Y="5.820" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p8397/V2</Name>
|
|
<Coord X="3.798" Y="5.820" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p8397/V3</Name>
|
|
<Coord X="3.798" Y="0.180" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p8397/V4</Name>
|
|
<Coord X="7.647" Y="0.180" Z="5.400"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_12</Name>
|
|
<SubId ID="14012"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="6.234" Y="5.820" X="7.012"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_11</Name>
|
|
<SubId ID="14011"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="7.644" Y="0.180" X="4.800"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_12</Name>
|
|
<SubId ID="16012"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="5.774" Y="1.673" X="5.846"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_303</Name>
|
|
<SubId ID="2303"></SubId>
|
|
<Group>
|
|
<Name>undest_room_303</Name>
|
|
<BBox_Min Z="5.200" Y="2.576" X="7.647"></BBox_Min>
|
|
<BBox_Max Z="8.100" Y="6.000" X="10.445"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="5.400" Y="2.756" X="7.827"></BBox_Min>
|
|
<BBox_Max Z="5.400" Y="5.820" X="10.265"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p8398</Name>
|
|
<Vertex>
|
|
<Name>p8398/V1</Name>
|
|
<Coord X="10.265" Y="5.820" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p8398/V2</Name>
|
|
<Coord X="7.827" Y="5.820" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p8398/V3</Name>
|
|
<Coord X="7.827" Y="2.756" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p8398/V4</Name>
|
|
<Coord X="10.265" Y="2.756" Z="5.400"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0010</Name>
|
|
<SubId ID="11010"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="6.225" Y="6.102" X="8.596"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_13</Name>
|
|
<SubId ID="14013"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="7.609" Y="5.820" X="9.815"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_13</Name>
|
|
<SubId ID="16013"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="5.774" Y="4.198" X="9.155"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_304</Name>
|
|
<SubId ID="2304"></SubId>
|
|
<Group>
|
|
<Name>undest_room_304</Name>
|
|
<BBox_Min Z="5.200" Y="0.000" X="7.647"></BBox_Min>
|
|
<BBox_Max Z="8.100" Y="2.756" X="10.445"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="5.400" Y="0.180" X="7.827"></BBox_Min>
|
|
<BBox_Max Z="5.400" Y="2.576" X="10.265"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p8399</Name>
|
|
<Vertex>
|
|
<Name>p8399/V1</Name>
|
|
<Coord X="10.265" Y="2.576" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p8399/V2</Name>
|
|
<Coord X="7.827" Y="2.576" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p8399/V3</Name>
|
|
<Coord X="7.827" Y="0.180" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p8399/V4</Name>
|
|
<Coord X="10.265" Y="0.180" Z="5.400"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0021</Name>
|
|
<SubId ID="11021"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="6.319" Y="-0.127" X="9.3"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_14</Name>
|
|
<SubId ID="16014"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="5.774" Y="1.388" X="9.106"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
<Switch>
|
|
<Name>SW_room_305</Name>
|
|
<SubId ID="2305"></SubId>
|
|
<Group>
|
|
<Name>undest_room_305</Name>
|
|
<BBox_Min Z="5.200" Y="-0.151" X="10.265"></BBox_Min>
|
|
<BBox_Max Z="8.100" Y="6.156" X="17.950"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="5.400" Y="0.180" X="10.445"></BBox_Min>
|
|
<BBox_Max Z="5.400" Y="5.820" X="17.860"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p8400</Name>
|
|
<Vertex>
|
|
<Name>p8400/V1</Name>
|
|
<Coord X="17.860" Y="5.820" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p8400/V2</Name>
|
|
<Coord X="10.445" Y="5.820" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p8400/V3</Name>
|
|
<Coord X="10.445" Y="0.180" Z="5.400"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p8400/V4</Name>
|
|
<Coord X="17.860" Y="0.180" Z="5.400"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0022</Name>
|
|
<SubId ID="11022"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="6.303" Y="-0.114" X="14.646"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0009</Name>
|
|
<SubId ID="11009"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="6.234" Y="6.098000000000001" X="14.589"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_14</Name>
|
|
<SubId ID="14014"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="7.609" Y="2.856" X="17.860"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_15</Name>
|
|
<SubId ID="16015"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="5.774" Y="3.042" X="14.152"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
</Group>
|
|
<Group>
|
|
<Name>floor_4</Name>
|
|
<Comment>base_height=8.1</Comment>
|
|
<Switch>
|
|
<Name>SW_room_401</Name>
|
|
<SubId ID="2401"></SubId>
|
|
<Group>
|
|
<Name>undest_room_401</Name>
|
|
<BBox_Min Z="7.900" Y="-0.737" X="0.000"></BBox_Min>
|
|
<BBox_Max Z="11.332" Y="6.741" X="18.238"></BBox_Max>
|
|
<Group>
|
|
<Name>FOOTPRINT</Name>
|
|
<BBox_Min Z="8.100" Y="0.180" X="0.090"></BBox_Min>
|
|
<BBox_Max Z="8.100" Y="5.820" X="17.860"></BBox_Max>
|
|
<Polygon>
|
|
<Name>p7346</Name>
|
|
<Vertex>
|
|
<Name>p7346/V1</Name>
|
|
<Coord X="17.860" Y="5.820" Z="8.100"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p7346/V2</Name>
|
|
<Coord X="0.090" Y="5.820" Z="8.100"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p7346/V3</Name>
|
|
<Coord X="0.090" Y="0.180" Z="8.100"></Coord>
|
|
</Vertex>
|
|
<Vertex>
|
|
<Name>p7346/V4</Name>
|
|
<Coord X="17.860" Y="0.180" Z="8.100"></Coord>
|
|
</Vertex>
|
|
</Polygon>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0023</Name>
|
|
<SubId ID="11023"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="10.891259999999999" Y="0.754" X="14.035"></Coord>
|
|
<Dir Z="0.866" Y="-0.500" X="-0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>REF_MOD_AP_0011</Name>
|
|
<SubId ID="11011"></SubId>
|
|
<Model NAME="REFMOD_01.flt"></Model>
|
|
<Coord Z="10.75326" Y="5.223" X="12.212"></Coord>
|
|
<Dir Z="0.866" Y="0.500" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_15</Name>
|
|
<SubId ID="14015"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="10.070" Y="3.066" X="17.860"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>CAMERA_IN_AP_16</Name>
|
|
<SubId ID="14016"></SubId>
|
|
<Model NAME="CAMERA_01.flt"></Model>
|
|
<Coord Z="8.915" Y="5.820" X="6.704"></Coord>
|
|
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_16</Name>
|
|
<SubId ID="16016"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="8.474" Y="2.912" X="1.934"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_17</Name>
|
|
<SubId ID="16017"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="8.474" Y="1.577" X="7.255"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_IN_AP_18</Name>
|
|
<SubId ID="16018"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="8.474" Y="2.902" X="12.979"></Coord>
|
|
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Switch>
|
|
</Group>
|
|
<Group>
|
|
<Name>floor_5</Name>
|
|
<Comment>base_height=11.33</Comment>
|
|
<Switch>
|
|
<Name>SW_room_501</Name>
|
|
<SubId ID="2501"></SubId>
|
|
<Group>
|
|
<Name>undest_room_501</Name>
|
|
<BBox_Min Z="9.076" Y="-0.737" X="0.000"></BBox_Min>
|
|
<BBox_Max Z="11.332" Y="6.741" X="18.238"></BBox_Max>
|
|
</Group>
|
|
</Switch>
|
|
</Group>
|
|
<External_Reference>
|
|
<Name>ZEG_MOD_AP_1</Name>
|
|
<SubId ID="12001"></SubId>
|
|
<Model NAME="ZEG_01.flt"></Model>
|
|
<Coord Z="2.250" Y="-0.100" X="0.100"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_1</Name>
|
|
<SubId ID="15001"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="1.478" X="-1.070"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_2</Name>
|
|
<SubId ID="15002"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="4.500" X="-1.070"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_3</Name>
|
|
<SubId ID="15003"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="7.070" X="2.500"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_4</Name>
|
|
<SubId ID="15004"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="7.070" X="6.786"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_5</Name>
|
|
<SubId ID="15005"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="7.070" X="11.072"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_6</Name>
|
|
<SubId ID="15006"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="7.070" X="15.358"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_7</Name>
|
|
<SubId ID="15007"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="-1.070" X="2.500"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_8</Name>
|
|
<SubId ID="15008"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="-1.070" X="6.786"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_9</Name>
|
|
<SubId ID="15009"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="-1.070" X="11.072"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_10</Name>
|
|
<SubId ID="15010"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="-1.070" X="15.358"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_11</Name>
|
|
<SubId ID="15011"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="4.500" X="19.070"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>IPS_OUT_AP_12</Name>
|
|
<SubId ID="15012"></SubId>
|
|
<Model NAME="SENSOR_01.flt"></Model>
|
|
<Coord Z="0.300" Y="1.478" X="19.070"></Coord>
|
|
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>BDI_P_1</Name>
|
|
<SubId ID="27001"></SubId>
|
|
<Model NAME="BDI.flt"></Model>
|
|
<Coord Z="0.600" Y="2.856" X="8.174"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>BDI_P_2</Name>
|
|
<SubId ID="27002"></SubId>
|
|
<Model NAME="BDI.flt"></Model>
|
|
<Coord Z="3.235" Y="2.856" X="8.174"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
<External_Reference>
|
|
<Name>BDI_P_3</Name>
|
|
<SubId ID="27003"></SubId>
|
|
<Model NAME="BDI.flt"></Model>
|
|
<Coord Z="5.919" Y="2.856" X="8.374"></Coord>
|
|
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
|
|
</External_Reference>
|
|
</Group>
|
|
</Header>
|
|
</STREIF> |