Files
qt6-migration-pipeline/external/BuildingModels/StaticMeshes/bldg_3224.flt.xml
T
2026-10-23 16:13:31 +00:00

1001 lines
52 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Thu Dec 02 13:08:46 2021 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_3224</Name>
<ModelId Id="1224"></ModelId>
<BBox_Min Z="-0.300" Y="-1.140" X="-1.140"></BBox_Min>
<BBox_Max Z="11.332" Y="7.140" X="19.140"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.000" X="0.000"></BBox_Min>
<BBox_Max Z="0.000" Y="6.000" X="17.970"></BBox_Max>
<Polygon>
<Name>p7820</Name>
<Vertex>
<Name>p7820/V1</Name>
<Coord X="17.970" Y="6.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p7820/V2</Name>
<Coord X="0.000" Y="6.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p7820/V3</Name>
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p7820/V4</Name>
<Coord X="17.970" Y="0.000" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0.00</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.300" Y="-0.151" X="0.000"></BBox_Min>
<BBox_Max Z="2.700" Y="6.000" X="7.755"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="0.090"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="7.575"></BBox_Max>
<Polygon>
<Name>p7816</Name>
<Vertex>
<Name>p7816/V1</Name>
<Coord X="7.575" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p7816/V2</Name>
<Coord X="4.761" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p7816/V3</Name>
<Coord X="4.761" Y="3.136" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p7816/V4</Name>
<Coord X="0.090" Y="3.136" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p7816/V5</Name>
<Coord X="0.090" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p7816/V6</Name>
<Coord X="7.575" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0013</Name>
<SubId ID="11013"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.995" Y="-0.108" X="5.952"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0012</Name>
<SubId ID="11012"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.142" Y="-0.189" X="2.827"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0003</Name>
<SubId ID="11003"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.288" Y="6.1160000000000005" X="5.737"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.199" Y="0.628" X="0.090"></Coord>
<Dir Z="0.000" Y="0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.660" X="2.583"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.477" X="6.243"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_102</Name>
<SubId ID="2102"></SubId>
<Group>
<Name>undest_room_102</Name>
<BBox_Min Z="-0.300" Y="3.136" X="0.000"></BBox_Min>
<BBox_Max Z="2.700" Y="6.156" X="4.761"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="3.316" X="0.090"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="4.581"></BBox_Max>
<Polygon>
<Name>p7817</Name>
<Vertex>
<Name>p7817/V1</Name>
<Coord X="4.581" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p7817/V2</Name>
<Coord X="0.090" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p7817/V3</Name>
<Coord X="0.090" Y="3.316" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p7817/V4</Name>
<Coord X="4.581" Y="3.316" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0004</Name>
<SubId ID="11004"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.026" Y="6.188000000000001" X="2.595"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_2</Name>
<SubId ID="14002"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.199" Y="5.501" X="0.090"></Coord>
<Dir Z="0.000" Y="0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_3</Name>
<SubId ID="16003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.538" X="2.314"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_103</Name>
<SubId ID="2103"></SubId>
<Group>
<Name>undest_room_103</Name>
<BBox_Min Z="-0.300" Y="0.000" X="7.575"></BBox_Min>
<BBox_Max Z="3.825" Y="6.000" X="10.445"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="7.755"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="10.265"></BBox_Max>
<Polygon>
<Name>p7818</Name>
<Vertex>
<Name>p7818/V1</Name>
<Coord X="10.265" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p7818/V2</Name>
<Coord X="7.755" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p7818/V3</Name>
<Coord X="7.755" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p7818/V4</Name>
<Coord X="10.265" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0014</Name>
<SubId ID="11014"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.439" Y="-0.112" X="9.613"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.285" Y="6.118" X="8.982"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_4</Name>
<SubId ID="16004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="2.913" X="9.069"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_104</Name>
<SubId ID="2104"></SubId>
<Group>
<Name>undest_room_104</Name>
<BBox_Min Z="-0.300" Y="-0.151" X="10.265"></BBox_Min>
<BBox_Max Z="2.700" Y="6.156" X="17.970"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="10.445"></BBox_Min>
<BBox_Max Z="0.000" Y="5.820" X="17.880"></BBox_Max>
<Polygon>
<Name>p7819</Name>
<Vertex>
<Name>p7819/V1</Name>
<Coord X="17.880" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p7819/V2</Name>
<Coord X="10.445" Y="5.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p7819/V3</Name>
<Coord X="10.445" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p7819/V4</Name>
<Coord X="17.880" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0015</Name>
<SubId ID="11015"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.149" Y="-0.189" X="14.384"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.049" Y="6.181" X="14.387"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_3</Name>
<SubId ID="14003"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.199" Y="0.636" X="17.880"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_5</Name>
<SubId ID="16005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.067" X="13.984"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=2.7</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.500" Y="-0.151" X="0.000"></BBox_Min>
<BBox_Max Z="5.400" Y="6.000" X="7.755"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="0.180" X="0.090"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="7.575"></BBox_Max>
<Polygon>
<Name>p7598</Name>
<Vertex>
<Name>p7598/V1</Name>
<Coord X="7.575" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p7598/V2</Name>
<Coord X="4.761" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p7598/V3</Name>
<Coord X="4.761" Y="3.136" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p7598/V4</Name>
<Coord X="0.090" Y="3.136" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p7598/V5</Name>
<Coord X="0.090" Y="0.180" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p7598/V6</Name>
<Coord X="7.575" Y="0.180" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0016</Name>
<SubId ID="11016"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.61" Y="-0.113" X="3.369"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0007</Name>
<SubId ID="11007"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.478" Y="6.112" X="5.717"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_4</Name>
<SubId ID="14004"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.899" Y="0.628" X="0.090"></Coord>
<Dir Z="0.000" Y="0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_6</Name>
<SubId ID="16006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.074" Y="4.408" X="6.232"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_7</Name>
<SubId ID="16007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.074" Y="1.684" X="3.037"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_202</Name>
<SubId ID="2202"></SubId>
<Group>
<Name>undest_room_202</Name>
<BBox_Min Z="2.500" Y="3.136" X="0.000"></BBox_Min>
<BBox_Max Z="5.400" Y="6.156" X="4.761"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="3.316" X="0.090"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="4.581"></BBox_Max>
<Polygon>
<Name>p7599</Name>
<Vertex>
<Name>p7599/V1</Name>
<Coord X="4.581" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p7599/V2</Name>
<Coord X="0.090" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p7599/V3</Name>
<Coord X="0.090" Y="3.316" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p7599/V4</Name>
<Coord X="4.581" Y="3.316" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0008</Name>
<SubId ID="11008"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.516" Y="6.109" X="2.314"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_13</Name>
<SubId ID="14013"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.929" Y="4.606" X="0.090"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_8</Name>
<SubId ID="16008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.074" Y="4.650" X="2.465"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_203</Name>
<SubId ID="2203"></SubId>
<Group>
<Name>undest_room_203</Name>
<BBox_Min Z="2.500" Y="0.000" X="7.575"></BBox_Min>
<BBox_Max Z="6.525" Y="6.000" X="10.445"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="0.180" X="7.755"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="10.265"></BBox_Max>
<Polygon>
<Name>p7600</Name>
<Vertex>
<Name>p7600/V1</Name>
<Coord X="10.265" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p7600/V2</Name>
<Coord X="7.755" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p7600/V3</Name>
<Coord X="7.755" Y="0.180" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p7600/V4</Name>
<Coord X="10.265" Y="0.180" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0017</Name>
<SubId ID="11017"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.629" Y="-0.113" X="9.285"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0006</Name>
<SubId ID="11006"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.564" Y="6.113" X="8.967"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_5</Name>
<SubId ID="14005"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="3.112" Y="5.820" X="9.731"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_9</Name>
<SubId ID="16009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.074" Y="1.355" X="9.046"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_204</Name>
<SubId ID="2204"></SubId>
<Group>
<Name>undest_room_204</Name>
<BBox_Min Z="2.500" Y="-0.151" X="10.265"></BBox_Min>
<BBox_Max Z="5.400" Y="6.156" X="17.970"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="0.180" X="10.445"></BBox_Min>
<BBox_Max Z="2.700" Y="5.820" X="17.880"></BBox_Max>
<Polygon>
<Name>p7601</Name>
<Vertex>
<Name>p7601/V1</Name>
<Coord X="17.880" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p7601/V2</Name>
<Coord X="10.445" Y="5.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p7601/V3</Name>
<Coord X="10.445" Y="0.180" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p7601/V4</Name>
<Coord X="17.880" Y="0.180" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0018</Name>
<SubId ID="11018"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.617" Y="-0.115" X="14.645"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0005</Name>
<SubId ID="11005"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="3.527" Y="6.103000000000001" X="14.12"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_6</Name>
<SubId ID="14006"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="4.899" Y="0.636" X="17.880"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_10</Name>
<SubId ID="16010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.074" Y="3.144" X="14.144"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_3</Name>
<Comment>base_height=5.4</Comment>
<Switch>
<Name>SW_room_301</Name>
<SubId ID="2301"></SubId>
<Group>
<Name>undest_room_301</Name>
<BBox_Min Z="5.200" Y="-0.151" X="0.000"></BBox_Min>
<BBox_Max Z="8.100" Y="6.000" X="7.755"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="5.400" Y="0.180" X="0.000"></BBox_Min>
<BBox_Max Z="5.400" Y="5.820" X="7.575"></BBox_Max>
<Polygon>
<Name>p6791</Name>
<Vertex>
<Name>p6791/V1</Name>
<Coord X="7.575" Y="5.820" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p6791/V2</Name>
<Coord X="4.761" Y="5.820" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p6791/V3</Name>
<Coord X="4.761" Y="3.136" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p6791/V4</Name>
<Coord X="0.000" Y="3.136" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p6791/V5</Name>
<Coord X="0.000" Y="0.180" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p6791/V6</Name>
<Coord X="7.575" Y="0.180" Z="5.400"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0019</Name>
<SubId ID="11019"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="6.324" Y="-0.12" X="3.356"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_7</Name>
<SubId ID="14007"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="7.599" Y="0.628" X="0.090"></Coord>
<Dir Z="0.000" Y="0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_11</Name>
<SubId ID="16011"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="5.774" Y="4.518" X="6.149"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_12</Name>
<SubId ID="16012"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="5.774" Y="1.609" X="2.762"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_302</Name>
<SubId ID="2302"></SubId>
<Group>
<Name>undest_room_302</Name>
<BBox_Min Z="5.200" Y="3.136" X="0.000"></BBox_Min>
<BBox_Max Z="8.100" Y="6.156" X="4.761"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="5.400" Y="3.316" X="0.090"></BBox_Min>
<BBox_Max Z="5.400" Y="5.820" X="4.581"></BBox_Max>
<Polygon>
<Name>p6792</Name>
<Vertex>
<Name>p6792/V1</Name>
<Coord X="4.581" Y="5.820" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p6792/V2</Name>
<Coord X="0.090" Y="5.820" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p6792/V3</Name>
<Coord X="0.090" Y="3.316" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p6792/V4</Name>
<Coord X="4.581" Y="3.316" Z="5.400"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0010</Name>
<SubId ID="11010"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="6.218" Y="6.105" X="2.308"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_13</Name>
<SubId ID="16013"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="5.774" Y="4.655" X="2.346"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_12</Name>
<SubId ID="14012"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="7.698" Y="4.606" X="0.090"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_303</Name>
<SubId ID="2303"></SubId>
<Group>
<Name>undest_room_303</Name>
<BBox_Min Z="5.200" Y="0.000" X="7.575"></BBox_Min>
<BBox_Max Z="9.225" Y="6.000" X="10.445"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="5.400" Y="0.180" X="7.755"></BBox_Min>
<BBox_Max Z="5.400" Y="5.820" X="10.265"></BBox_Max>
<Polygon>
<Name>p6793</Name>
<Vertex>
<Name>p6793/V1</Name>
<Coord X="10.265" Y="5.820" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p6793/V2</Name>
<Coord X="7.755" Y="5.820" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p6793/V3</Name>
<Coord X="7.755" Y="0.180" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p6793/V4</Name>
<Coord X="10.265" Y="0.180" Z="5.400"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0020</Name>
<SubId ID="11020"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="6.338" Y="-0.119" X="9.309"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_8</Name>
<SubId ID="14008"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="5.812" Y="5.820" X="9.731"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_14</Name>
<SubId ID="16014"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="5.774" Y="1.396" X="9.044"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_304</Name>
<SubId ID="2304"></SubId>
<Group>
<Name>undest_room_304</Name>
<BBox_Min Z="5.200" Y="-0.151" X="10.265"></BBox_Min>
<BBox_Max Z="8.100" Y="6.156" X="17.970"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="5.400" Y="0.180" X="10.445"></BBox_Min>
<BBox_Max Z="5.400" Y="5.820" X="17.880"></BBox_Max>
<Polygon>
<Name>p6794</Name>
<Vertex>
<Name>p6794/V1</Name>
<Coord X="17.880" Y="5.820" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p6794/V2</Name>
<Coord X="10.445" Y="5.820" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p6794/V3</Name>
<Coord X="10.445" Y="0.180" Z="5.400"></Coord>
</Vertex>
<Vertex>
<Name>p6794/V4</Name>
<Coord X="17.880" Y="0.180" Z="5.400"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0021</Name>
<SubId ID="11021"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="6.295" Y="-0.12" X="14.678"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0009</Name>
<SubId ID="11009"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="6.238" Y="6.104" X="14.127"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_9</Name>
<SubId ID="14009"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="7.599" Y="0.636" X="17.880"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_15</Name>
<SubId ID="16015"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="5.774" Y="3.119" X="14.070"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_4</Name>
<Comment>base_height=8.1</Comment>
<Switch>
<Name>SW_room_401</Name>
<SubId ID="2401"></SubId>
<Group>
<Name>undest_room_401</Name>
<BBox_Min Z="7.900" Y="-0.737" X="0.000"></BBox_Min>
<BBox_Max Z="11.332" Y="6.741" X="18.282"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="8.100" Y="0.180" X="0.090"></BBox_Min>
<BBox_Max Z="8.100" Y="5.820" X="17.880"></BBox_Max>
<Polygon>
<Name>p6007</Name>
<Vertex>
<Name>p6007/V1</Name>
<Coord X="17.880" Y="5.820" Z="8.100"></Coord>
</Vertex>
<Vertex>
<Name>p6007/V2</Name>
<Coord X="0.090" Y="5.820" Z="8.100"></Coord>
</Vertex>
<Vertex>
<Name>p6007/V3</Name>
<Coord X="0.090" Y="0.180" Z="8.100"></Coord>
</Vertex>
<Vertex>
<Name>p6007/V4</Name>
<Coord X="17.880" Y="0.180" Z="8.100"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0022</Name>
<SubId ID="11022"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="10.86326" Y="0.7609999999999999" X="13.079"></Coord>
<Dir Z="0.866" Y="-0.500" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0011</Name>
<SubId ID="11011"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="10.75826" Y="5.226999999999999" X="14.845"></Coord>
<Dir Z="0.866" Y="0.500" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_10</Name>
<SubId ID="14010"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="9.942" Y="3.007" X="17.880"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_11</Name>
<SubId ID="14011"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="8.858" Y="5.820" X="8.945"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_16</Name>
<SubId ID="16016"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="8.474" Y="3.088" X="3.867"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_17</Name>
<SubId ID="16017"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="8.474" Y="1.188" X="9.093"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_18</Name>
<SubId ID="16018"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="8.474" Y="3.060" X="14.158"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_5</Name>
<Comment>base_height=11.33</Comment>
<Switch>
<Name>SW_room_501</Name>
<SubId ID="2501"></SubId>
<Group>
<Name>undest_room_501</Name>
<BBox_Min Z="9.076" Y="-0.737" X="0.000"></BBox_Min>
<BBox_Max Z="11.332" Y="6.741" X="18.282"></BBox_Max>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="2.250" Y="-0.100" X="0.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.478" X="-1.070"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.500" X="-1.070"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.070" X="2.500"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.070" X="6.786"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_5</Name>
<SubId ID="15005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.070" X="11.072"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_6</Name>
<SubId ID="15006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.070" X="15.358"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_7</Name>
<SubId ID="15007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.070" X="2.500"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_8</Name>
<SubId ID="15008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.070" X="6.786"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_9</Name>
<SubId ID="15009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.070" X="11.072"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_10</Name>
<SubId ID="15010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.070" X="15.358"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_11</Name>
<SubId ID="15011"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.500" X="19.070"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_12</Name>
<SubId ID="15012"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.478" X="19.070"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.600" Y="2.754" X="7.475"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_2</Name>
<SubId ID="27002"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="6.180" Y="2.554" X="7.475"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_3</Name>
<SubId ID="27003"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="3.211" Y="2.754" X="7.475"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>