Files
qt6-migration-pipeline/external/BuildingModels/StaticMeshes/bldg_3272.flt.xml
T
2026-10-23 16:13:31 +00:00

543 lines
28 KiB
XML
Executable File

<?xml version="1.0" ?>
<!--fltHdrLastDate Wed Dec 08 13:43:51 2021 - PostProcessed by SLTE $Rev: 56086 $-->
<STREIF>
<Header>
<Group>
<Name>bldg_3272</Name>
<ModelId Id="1272"></ModelId>
<BBox_Min Z="-0.300" Y="-1.070" X="-1.070"></BBox_Min>
<BBox_Max Z="5.996" Y="13.070" X="7.110"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.000" X="0.000"></BBox_Min>
<BBox_Max Z="0.000" Y="12.000" X="6.040"></BBox_Max>
<Polygon>
<Name>p2364</Name>
<Vertex>
<Name>p2364/V1</Name>
<Coord X="0.000" Y="12.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2364/V2</Name>
<Coord X="0.000" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2364/V3</Name>
<Coord X="6.040" Y="0.000" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2364/V4</Name>
<Coord X="6.040" Y="12.000" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>floor_1</Name>
<Comment>base_height=0.00</Comment>
<Switch>
<Name>SW_room_101</Name>
<SubId ID="2101"></SubId>
<Group>
<Name>undest_room_101</Name>
<BBox_Min Z="-0.300" Y="8.301" X="-0.114"></BBox_Min>
<BBox_Max Z="2.700" Y="12.000" X="6.154"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="8.679" X="0.180"></BBox_Min>
<BBox_Max Z="0.000" Y="11.820" X="5.860"></BBox_Max>
<Polygon>
<Name>p2366</Name>
<Vertex>
<Name>p2366/V1</Name>
<Coord X="5.860" Y="11.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2366/V2</Name>
<Coord X="0.180" Y="11.820" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2366/V3</Name>
<Coord X="0.180" Y="8.679" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2366/V4</Name>
<Coord X="5.860" Y="8.679" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0007</Name>
<SubId ID="11007"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.053" Y="10.639" X="-0.20800000000000002"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0005</Name>
<SubId ID="11005"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.328" Y="12.145999999999999" X="1.503"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0012</Name>
<SubId ID="11012"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.018" Y="9.034" X="6.258"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0004</Name>
<SubId ID="11004"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="1.888" Y="12.104999999999999" X="4.587"></Coord>
<Dir Z="0.000" Y="1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_1</Name>
<SubId ID="16001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="10.249" X="3.020"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_2</Name>
<SubId ID="14002"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.200" Y="11.820" X="0.764"></Coord>
<Dir Z="0.000" Y="-1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_1</Name>
<SubId ID="14001"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.200" Y="11.362" X="5.860"></Coord>
<Dir Z="0.000" Y="0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_102</Name>
<SubId ID="2102"></SubId>
<Group>
<Name>undest_room_102</Name>
<BBox_Min Z="-0.300" Y="5.822" X="0.000"></BBox_Min>
<BBox_Max Z="3.847" Y="8.679" X="6.040"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="6.002" X="0.180"></BBox_Min>
<BBox_Max Z="0.000" Y="8.499" X="5.860"></BBox_Max>
<Polygon>
<Name>p2367</Name>
<Vertex>
<Name>p2367/V1</Name>
<Coord X="5.860" Y="8.499" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2367/V2</Name>
<Coord X="0.180" Y="8.499" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2367/V3</Name>
<Coord X="0.180" Y="6.002" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2367/V4</Name>
<Coord X="5.860" Y="6.002" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0008</Name>
<SubId ID="11008"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.233" Y="7.241" X="-0.114"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0011</Name>
<SubId ID="11011"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.31" Y="7.257" X="6.164000000000001"></Coord>
<Dir Z="0.000" Y="-0.000" X="1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_2</Name>
<SubId ID="16002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="1.570" Y="7.250" X="5.234"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_3</Name>
<SubId ID="16003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="7.250" X="1.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_103</Name>
<SubId ID="2103"></SubId>
<Group>
<Name>undest_room_103</Name>
<BBox_Min Z="-0.300" Y="2.804" X="2.581"></BBox_Min>
<BBox_Max Z="2.700" Y="6.199" X="6.040"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="2.984" X="2.761"></BBox_Min>
<BBox_Max Z="0.000" Y="5.822" X="5.860"></BBox_Max>
<Polygon>
<Name>p2368</Name>
<Vertex>
<Name>p2368/V1</Name>
<Coord X="5.860" Y="5.822" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2368/V2</Name>
<Coord X="2.761" Y="5.822" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2368/V3</Name>
<Coord X="2.761" Y="2.984" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2368/V4</Name>
<Coord X="5.860" Y="2.984" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>IPS_IN_AP_4</Name>
<SubId ID="16004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="4.403" X="4.311"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_3</Name>
<SubId ID="14003"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.200" Y="5.535" X="5.860"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_104</Name>
<SubId ID="2104"></SubId>
<Group>
<Name>undest_room_104</Name>
<BBox_Min Z="-0.300" Y="-0.072" X="2.581"></BBox_Min>
<BBox_Max Z="2.700" Y="2.984" X="6.040"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="2.761"></BBox_Min>
<BBox_Max Z="0.000" Y="2.804" X="5.860"></BBox_Max>
<Polygon>
<Name>p2369</Name>
<Vertex>
<Name>p2369/V1</Name>
<Coord X="5.860" Y="2.804" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2369/V2</Name>
<Coord X="2.761" Y="2.804" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2369/V3</Name>
<Coord X="2.761" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2369/V4</Name>
<Coord X="5.860" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0002</Name>
<SubId ID="11002"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.028" Y="-0.201" X="3.262"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_5</Name>
<SubId ID="16005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="1.492" X="4.311"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_4</Name>
<SubId ID="14004"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="2.200" Y="0.559" X="5.860"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
<Switch>
<Name>SW_room_105</Name>
<SubId ID="2105"></SubId>
<Group>
<Name>undest_room_105</Name>
<BBox_Min Z="-0.300" Y="0.000" X="-0.114"></BBox_Min>
<BBox_Max Z="2.700" Y="6.002" X="2.761"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="0.000" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="0.000" Y="5.822" X="2.581"></BBox_Max>
<Polygon>
<Name>p2370</Name>
<Vertex>
<Name>p2370/V1</Name>
<Coord X="2.581" Y="5.822" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2370/V2</Name>
<Coord X="0.180" Y="5.822" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2370/V3</Name>
<Coord X="0.180" Y="0.180" Z="0.000"></Coord>
</Vertex>
<Vertex>
<Name>p2370/V4</Name>
<Coord X="2.581" Y="0.180" Z="0.000"></Coord>
</Vertex>
</Polygon>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0009</Name>
<SubId ID="11009"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.052" Y="4.867" X="-0.186"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0001</Name>
<SubId ID="11001"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="2.299" Y="-0.122" X="1.586"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_6</Name>
<SubId ID="16006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="3.001" X="1.381"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_2</Name>
<Comment>base_height=2.7</Comment>
<Switch>
<Name>SW_room_201</Name>
<SubId ID="2201"></SubId>
<Group>
<Name>undest_room_201</Name>
<BBox_Min Z="2.500" Y="-0.200" X="-0.693"></BBox_Min>
<BBox_Max Z="5.996" Y="12.220" X="6.733"></BBox_Max>
<Group>
<Name>FOOTPRINT</Name>
<BBox_Min Z="2.700" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="2.700" Y="11.820" X="5.860"></BBox_Max>
<Polygon>
<Name>p2381</Name>
<Vertex>
<Name>p2381/V1</Name>
<Coord X="0.180" Y="0.180" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p2381/V2</Name>
<Coord X="5.860" Y="0.180" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p2381/V3</Name>
<Coord X="5.860" Y="11.820" Z="2.700"></Coord>
</Vertex>
<Vertex>
<Name>p2381/V4</Name>
<Coord X="0.180" Y="11.820" Z="2.700"></Coord>
</Vertex>
</Polygon>
</Group>
<Group>
<Name>subroom_1</Name>
<BBox_Min Z="2.700" Y="0.180" X="0.180"></BBox_Min>
<BBox_Max Z="2.700" Y="6.002" X="5.860"></BBox_Max>
</Group>
<Group>
<Name>subroom_2</Name>
<BBox_Min Z="2.700" Y="6.002" X="0.180"></BBox_Min>
<BBox_Max Z="2.700" Y="8.499" X="2.236"></BBox_Max>
</Group>
<Group>
<Name>subroom_3</Name>
<BBox_Min Z="2.700" Y="8.499" X="0.180"></BBox_Min>
<BBox_Max Z="2.700" Y="11.820" X="5.860"></BBox_Max>
</Group>
<External_Reference>
<Name>REF_MOD_AP_0006</Name>
<SubId ID="11006"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.486" Y="12.104" X="3.006"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0010</Name>
<SubId ID="11010"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="5.203259999999999" Y="3.051" X="0.5489999999999999"></Coord>
<Dir Z="0.866" Y="-0.000" X="-0.500"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0003</Name>
<SubId ID="11003"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="4.451" Y="-0.122" X="3.047"></Coord>
<Dir Z="0.000" Y="-1.000" X="-0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>REF_MOD_AP_0013</Name>
<SubId ID="11013"></SubId>
<Model NAME="REFMOD_01.flt"></Model>
<Coord Z="5.18326" Y="8.983" X="5.47"></Coord>
<Dir Z="0.866" Y="-0.000" X="0.500"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_7</Name>
<SubId ID="16007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.000" Y="10.249" X="2.930"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_IN_AP_8</Name>
<SubId ID="16008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="3.000" Y="3.091" X="3.020"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_5</Name>
<SubId ID="14005"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="5.100" Y="0.180" X="3.048"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>CAMERA_IN_AP_6</Name>
<SubId ID="14006"></SubId>
<Model NAME="CAMERA_01.flt"></Model>
<Coord Z="3.500" Y="7.071" X="5.860"></Coord>
<Dir Z="0.000" Y="-0.000" X="-1.000"></Dir>
</External_Reference>
</Group>
</Switch>
</Group>
<Group>
<Name>floor_3</Name>
<Comment>base_height=6.0</Comment>
<Switch>
<Name>SW_room_301</Name>
<SubId ID="2301"></SubId>
<Group>
<Name>undest_room_301</Name>
<BBox_Min Z="3.762" Y="-0.200" X="-0.693"></BBox_Min>
<BBox_Max Z="5.996" Y="12.220" X="6.733"></BBox_Max>
</Group>
</Switch>
</Group>
<External_Reference>
<Name>ZEG_MOD_AP_1</Name>
<SubId ID="12001"></SubId>
<Model NAME="ZEG_01.flt"></Model>
<Coord Z="2.250" Y="-0.100" X="0.100"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_1</Name>
<SubId ID="15001"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="9.500" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_2</Name>
<SubId ID="15002"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="6.000" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_3</Name>
<SubId ID="15003"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="2.500" X="-1.000"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_4</Name>
<SubId ID="15004"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="1.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_5</Name>
<SubId ID="15005"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="-1.000" X="4.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_6</Name>
<SubId ID="15006"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="2.500" X="7.040"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_7</Name>
<SubId ID="15007"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="6.000" X="7.040"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_8</Name>
<SubId ID="15008"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="9.500" X="7.040"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_9</Name>
<SubId ID="15009"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="13.000" X="4.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>IPS_OUT_AP_10</Name>
<SubId ID="15010"></SubId>
<Model NAME="SENSOR_01.flt"></Model>
<Coord Z="0.300" Y="13.000" X="1.500"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
<External_Reference>
<Name>BDI_P_1</Name>
<SubId ID="27001"></SubId>
<Model NAME="BDI.flt"></Model>
<Coord Z="0.550" Y="8.000" X="0.280"></Coord>
<Dir Z="0.000" Y="1.000" X="0.000"></Dir>
</External_Reference>
</Group>
</Header>
</STREIF>